Skip to content

A Clinical Study on the Use of the Sentinel Cerebral Protection Device During TAVR for the Prevention of Procedure-Related Stroke

A Clinical Study on the Use of the Sentinel Cerebral Protection Device During TAVR for the Prevention of Procedure-Related Stroke

Status
Enrolling by invitation
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT07045233
Acronym
SENTINEL-TAVR
Enrollment
200
Registered
2025-07-01
Start date
2025-06-01
Completion date
2028-07-31
Last updated
2025-07-08

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Aortic Stenosis Treated With TAVI, Stroke, Transcatheter Aortic Valve Replacement (TAVR)

Keywords

stroke, Cerebral Protection Device, TAVR

Brief summary

After more than a decade of development, transcatheter aortic valve replacement (TAVR) is now a standard, guideline-recommended treatment for all symptomatic patients with severe aortic stenosis, regardless of their surgical risk. However, stroke remains a risk for these patients after TAVR. Given its severe impact-significantly increasing post-procedure mortality and severely affecting quality of life-preventing TAVR-related stroke is an urgent problem we need to solve. The Sentinel Cerebral Protection Device is a percutaneous dual-filter brain protection system. During the procedure, the Sentinel device's filters capture blood clots and tissue debris. After the operation, the captured clots and debris are removed from the body along with the device. Its safety and effectiveness have been validated. Therefore, this project plans to conduct a multi-center registry clinical study to: Develop a widespread neurological risk prediction model. Create a strict, standardized prevention protocol. Boost awareness of perioperative stroke prevention during TAVR. Provide practical clinical experience. By doing so, we aim to better prevent strokes in patients undergoing TAVR.

Interventions

Deploy a Sentinel cerebral protection device during TAVR for patient with aortic stenosis.

DIAGNOSTIC_TESTMRI

Patients receive head MRI before and after the surgery in order to determine the stroke incidence.

Sponsors

China National Center for Cardiovascular Diseases
Lead SponsorOTHER_GOV

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Patients who meet the surgical indications for Transcatheter Aortic Valve Replacement (TAVR), diagnosed as symptomatic severe aortic stenosis, receive a Sentinel Cerebral Protection System during the procedure, and are adult patients who have been informed and consented to participate in this study.

Exclusion criteria

* History of cerebral disease within 1 year prior to the procedure (e.g., stroke, cerebral hemorrhage, brain tumor, encephalitis, traumatic brain injury, or other craniocerebral-related diseases). History of previous open-chest surgery or previous heart valve replacement. Patients with left ventricular ejection fraction ≤ 30%. Presence of contraindications for MRI examination. Patients with claustrophobia. Patients unable to comply with follow-up.

Design outcomes

Primary

MeasureTime frameDescription
The Rate of Stroke Through 72 Hours Post TAVR Procedure or Discharge (Whichever Comes First)From enrollment to 72 hours post surgery or discharge (whichever comes first)All stroke (hemorrhagic, ischemic, or undetermined status; disabling or nondisabling) through 72 hours post TAVR procedure or discharge (whichever comes first), as adjudicated by an independent Clinical Events Committee (CEC) and using Neurologic Academic Research Consortium (NeuroARC) definitions.

Countries

China

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026