Skip to content

Using Wearable Sensors To Understand Low Blood Sugar in Type 1 Diabetes

Assessment of Impaired Counterregulatory Hormones and Cardiovascular Risk Using Modern Wearable Sensors in People Living With Type 1 Diabetes.

Status
Not yet recruiting
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT06727071
Acronym
Wear WOLF
Enrollment
20
Registered
2024-12-10
Start date
2025-02-01
Completion date
2026-06-30
Last updated
2024-12-10

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Type 1 Diabetes Mellitus

Keywords

T1D, Type 1 Diabetes, Type 1

Brief summary

This is a single-site study using wearable sensor technology (CGM and smartwatch) to better explain low blood sugars in patients living with type 1 diabetes. Up to 20 participants with T1D will wear a continuous glucose monitor (CGM) and a smartwatch to collect information about hypoglycemia (low blood sugar), heart rate variability (HRV), and sleep for 4 weeks. The main goal is to create a hypoglycemia risk score using wearable sensor metrics that can be easily applied to all patients with T1D to identify those at greater risk of hypoglycemia.

Detailed description

This is a single-site study using wearable sensor technology (continuous glucose monitor \[CGM\] and smartwatch actigraphy) to stratify hypoglycemia and cardiovascular risk in patients living with type 1 diabetes. To carry out this research, 20 local participants with Type 1 Diabetes (T1D) will wear CGM and smartwatches to quantify hypoglycemia, heart rate variability (HRV), and sleep actigraphy for 4 weeks. These data will be correlated with counterregulatory hormone levels collected during hyperinsulinemic-hypoglycemic (HHC) clamp. The goal is to create a hypoglycemia risk score using wearable sensor metrics that can be easily applied to all patients with T1D to identify those with impaired counter-regulation in the clinical setting (Aim 1). How hypoglycemia exposure impacts cardiometabolic health in T1D will also be explored. Participants will complete ambulatory blood pressure monitoring (ABPM), flow mediated dilation (FMD), reactive hyperemia-peripheral artery tonometry (RH-PAT), HRV assessment via wearable smartwatch, and serum inflammatory and coagulation evaluation before and after hyperinsulinemic-hypoglycemic clamp to investigate the effect of hypoglycemia on these cardiovascular (CV) risk factors (Aim 2,3). Subjects will be monitored for 4 weeks prior, and 1 week after hypoglycemic clamp.

Interventions

A continuous infusion of 20% dextrose will be maintained throughout the procedure, while a variable rate of insulin infusion will be used to control participants blood glucose level.

Sponsors

National Institutes of Health (NIH)
CollaboratorNIH
University of California, San Diego
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 75 Years
Healthy volunteers
No

Inclusion criteria

1. Men and women between the ages of 18 and 75 years old, inclusive, at the time of screening; 2. Females of non-childbearing potential must be ≥ 1 year post-menopausal or documented as being surgically sterile. Females of childbearing potential must agree to use two methods of contraception during the entire study; 3. Diagnosed with Type 1 diabetes \>2-year duration based on clinical history or as defined by the current American Diabetes Association (ADA) criteria; 4. Using hybrid closed loop, standard pump, or multiple daily injections; 5. Able to use a Continuous Glucose Monitoring (CGM) device; 6. A1c \> 7% and ≤ 10%: 7. eGFR ≥ 60 mL/min/1.73m²; 8. BMI 18.5-35.0 kg/m2 ; 9. Able to provide written informed consent approved by an Institutional Review Board (IRB).

Exclusion criteria

1. History or evidence of clinically significant disorder or condition that, in the opinion of the Investigator, would pose a risk to subject safety or interfere with the study evaluation, procedures, or completion; 2. History of pancreatitis, medullary thyroid carcinoma or liver disease: 3. Clinically significant diagnosis of anemia (Hemoglobin \< 9 g/dl at screening); 4. Body Mass Index (BMI) \< 18.5 kg/m2 and/or weight \<50kg; 5. Body Mass Index (BMI) \> 35 kg/m2; 6. Whole blood donation of 1 pint (500 mL) within 8 weeks prior to Screening. Donations of plasma, packed RBCs, platelets or quantities less than 500 mL are allowed at investigator discretion; 7. Current or recent (within 1 month of screening) use of diabetes medications other than insulin; (examples include GLP-1, RA, SGLT-2i, Pramlintide, Metformin); 8. Women who are pregnant or lactating/breastfeeding; 9. Unable or unwilling to follow the study protocol or who are non-compliant with screening appointments or study visits; 10. Any other condition(s) that might reduce the chance of obtaining study data, or that might cause safety concerns, or that might compromise the ability to give truly informed consent; 11. Severe hypoglycemic events or DKA within 3 months; 12. Currently using beta-blockers; 13. Adrenal insufficiency diagnosis.

Design outcomes

Primary

MeasureTime frameDescription
Hypoglycemic Clamp Epinephrine Response160 MinutesThe change in epinephrine from the start of the clamp to the end as measured in pg/mL.

Secondary

MeasureTime frameDescription
CGM Time In Range4 weeksPercent time between 70-180 mg/dL as measured by continuous glucose monitor.
CGM Time Below Range4 weeksPercent time \<70 mg/dL as measured by continuous glucose monitor.
Peripheral Artery Tonometry4 weeksChange in peripheral artery tonometry as measured by Endo-PAT score.
Brachial Flow Mediated Dilation4 weeksChange in brachial artery vasodilation as measured by flow mediated dilation.

Countries

United States

Contacts

Primary ContactProgram Manager
t1dresearch@health.ucsd.edu858-246-2169

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026