Skip to content

Porous Tantalum Rods Improve the Hip Joint Function of Patients With Avascular Necrosis of the Femoral Head

Porous Tantalum Rods Improve the Hip Joint Function of Patients With Avascular Necrosis of the Femoral Head After Femoral Neck Fracture Surgery: a Randomized Controlled Trial

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02877472
Enrollment
100
Registered
2016-08-24
Start date
2015-05-31
Completion date
2017-05-31
Last updated
2016-08-24

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Femoral Neck Fracture

Brief summary

To confirm 1) whether, compared with core decompression alone, core decompression with porous tantalum rod implantation improves the hip joint function of patients with avascular necrosis of the femoral head after femoral neck fracture surgery, 2) whether porous tantalum rod shows favorable biocompatibility with the human body, and 3) whether this treatment method is feasible for treating avascular necrosis of the femoral head after femoral neck fracture surgery.

Detailed description

History and current status of related studies: Femoral neck fracture can render the blood supply to the femoral head insufficient, leading to avascular necrosis of the femoral head. This often increases treatment difficulty and can have a strong influence on the recovery of hip joint function. Although core decompression for treatment of avascular necrosis of the femoral head has been largely used in clinical settings, the mid-term therapeutic effects are not satisfactory in some patients. Biocompatibility is defined as the ability of a biomaterial, prosthesis, or medical device to perform with an appropriate host response. The biocompatibility of a bone implant and host influences the therapeutic effects. Therefore, biomaterials that are less likely to induce negative host responses may increase the therapeutic effects of such treatments for orthopedic diseases. A porous tantalum rod is a bone trabecula-like metal implant that is used to support weight-bearing areas of necrotic bone, preventing further collapse of the necrotic area. This implant has exhibited favorable effects in the early treatment of avascular necrosis of the femoral head. Although previous reports have focused on porous tantalum rod implantation for clinical treatment of avascular necrosis of the femoral head after fermoral neck fracture, few have assessed the long-term therapeutic effects or biocompatibility of porous tantalum rods. Adverse events Possible adverse events include any expected or unexpected symptoms. If severe adverse events occur, information including the date of occurrence and measures taken related to the treatment of the adverse events will be reported to the principal investigator and the institutional review board within 24 hours. Data collection, management, analysis, and open access Data collection: Case report forms with demographic data, disease diagnosis, accompanying diseases, drug allergy history, and adverse events will be collected , processed using Epidata software, collated, and then electrically recorded using a double-data entry strategy by data managers. Data management: The locked electronic database will not be altered in any way, and will only be available to the project manager. Paper and electronic data regarding screening, informed consent, and clinical outcomes will be preserved at the Affiliated Hospital of Nantong University, China. Data analysis: The electronic database will be made available to a professional statistician for statistical analysis. An outcome analysis report will be made by the statistician and submitted to the lead researchers. An independent data monitoring committee will supervise and manage the trial data with the goal of ensuring a scientific and stringent trial process, resulting in accurate and complete data. Data open access: Anonymized trial data will be published at http://www.figshare.com. Statistical analysis Statistical analysis will be performed by a statistician using SPSS 19.0 software and will follow the intention-to-treat principle. Normally distributed measurement data will be expressed as a mean, standard deviation, min, and max. Non-normally distributed measurement data will be expressed as a lower quartile (q1), median, and upper quartile (q3). McNemar's test will be used to compare the percentage of patients with excellent hip joint function as per Harris hip scores 12 months after surgery, the percentage of patients presenting with femoral head collapse, prosthesis loosening, peri-prosthesis infection, and incidence of complications 6 and 12 months after surgery. The Mann-Whitney U test will be used to compare the VAS score prior to and 1, 6, and 12 months after surgery. Statistical significance will be accepted when α = 0.05.

Interventions

DEVICEporous tantalum rod

Patients with avascular necrosis of the femoral head after femoral head fracture surgery receive treatment of core decompression and porous tantalum rod implantation

Patients with avascular necrosis of the femoral head after femoral head fracture surgery will undergo core decompression.

Sponsors

Qinghai University
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 80 Years
Healthy volunteers
No

Inclusion criteria

* Patients with fracture nonunion as indicated by a clear fracture line 12 months after femoral neck fracture; avascular necrosis of the femoral head as shown by cystic degeneration, sclerosis, and uneven density on X-ray images and CT scans * Patients with avascular necrosis of the femoral head after femoral neck fracture surgery who underwent internal fixation between 1 January 2016 and 31 May 2017 * Age 18-80 years * Any sex and nationality * Provision of signed informed consent to participate in the trial

Exclusion criteria

* Poor general health * Chronic disease or history of surgery * Alcohol abuse or long-term use of hormone drugs * Unable or declines to cooperate with treatment and examination because of language and/or mental disorders * Unable or declines to cooperate with rehabilitation treatment because of mental and/or psychological disorders

Design outcomes

Primary

MeasureTime frameDescription
Harris hip scores12 months after surgeryTo evaluate the recovery of hip joint function. The Harris hip score ranges from 0-100 points with higher scores indicating better hip joint function. Hip joint function is scored as follows: ≥ 90 is excellent, 80-89 very good, 70-79 good, and \< 70 poor.

Secondary

MeasureTime frameDescription
Incidences of complications6 and 12 months after surgeryTo evaluate the safety of various implantation methods.
Visual Analogue Scale (VAS)prior to and 1, 6, and 12 months after surgeryTo evaluate the severity of pain and ranges from 0-10, with higher scores indicating more severe pain.

Countries

China

Contacts

Primary ContactHeling Zhang, Master
helingzhang_qu@sina.com8613997262938

Outcome results

None listed