Short-term physiological ocular responses to near work in healthy young adults, including changes in accommodation, subfoveal choroidal thickness, and axial length, with comparisons between myopic and non-myopic participants. Near work, accommodation, accommodative lag, accommodative microfluctuations, choroidal thickness, axial length, myopia, digital reading, printed reading, refractive error, optical coherence tomography, young adults, ocular biometry, crossover study
Conditions
Interventions
Sponsors
Eligibility
Inclusion criteria
Inclusion criteria: 1. Age 18 to 25 years, 2. Spherical equivalent refraction between minus 8.00 D and plus 1.00 D., 3. Astigmatism less than 1.00 D.,4. Best-corrected visual acuity of 0.00 logMAR or better, 5. Healthy ocular status, 6. Normal binocular and accommodative function, 7. Able to provide written informed consent.
Exclusion criteria
Exclusion criteria: 1. Presence of ocular pathology, 2. Previous ocular surgery, 3. Systemic disease affecting vision or ocular measurements, 4. Abnormal binocular vision or accommodative function, 5. Failure to meet the required measurement-quality criteria.
Design outcomes
Primary
| Measure | Time frame |
|---|---|
| Accommodative lag Baseline and immediately after each 20-minute digital or printed reading condition. Accommodative lag in dioptres, calculated as 2.50 dioptres minus the accommodative response recorded monocularly for 60 seconds at 5 Hz using the Grand Seiko WAM-5500,Accommodative microfluctuations Baseline and immediately after each 20-minute digital or printed reading condition. Root mean square variability in dioptres of a 60-second monocular accommodative recording obtained at 5 Hz using the Grand Seiko WAM-5500, after removal of blink artefacts,Subfoveal choroidal thickness Baseline and immediately after each 20-minute digital or printed reading condition. Subfoveal choroidal thickness in micrometres measured using automated segmentation of a 12 by 9 mm 3D Wide Scan obtained with the Topcon 3D OCT Maestro 2.,Axial length Baseline and immediately after each 20-minute digital or printed reading condition. Axial length in millimetres measured using the IOLMaster 500. Five consecutive acceptable measurements were obtained and averaged at each assessment. | — |
Secondary
| Measure | Time frame |
|---|---|
| Difference in ocular responses between refractive groups Change from baseline to immediately after each 20-minute digital or printed reading condition. Change from baseline in accommodative lag, accommodative microfluctuations, subfoveal choroidal thickness, and axial length compared between myopic and non-myopic participants. | — |