The Relationship of Vitamin D3 Deficiency Level with the Primary and Secondary Stability of The Dental Implant: A Randomized Controlled Study

The Relationship of Vitamin D3 Deficiency Level with the Primary and Secondary Stability of The Dental Implant: A Randomized Controlled Study

Status
Active, not recruiting
Phases
Phase 4
Study type
Interventional
Source
TCTR
Registry ID
TCTR20260603004
Enrollment
40
Registered
2026-06-03
Start date
2025-01-16
Completion date
Unknown
Last updated
2026-08-03

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Vitamin D3 deficiency Dental implant stability Vitamin D3 Vitamin D deficiency Dental implants Implant stability Osseointegration Bone density

Interventions

Participants in this group received oral vitamin D3 supplementation 50000 IU once weekly for two months according to the study protocol,Participants in this group did not receive vitamin D3 supplement
Experimental Dietary Supplement,No Intervention No treatment
Vitamin D3 supplementation,No vitamin D3 supplementation

Sponsors

University of Baghdad
Lead Sponsor

Eligibility

Sex/Gender
Female
Age
18 Years to No maximum

Inclusion criteria

Inclusion criteria: 1.Female patients aged 18 years or older with single or multiple missing teeth in the maxilla or mandible. 2.Straightforward implant cases according to the SAC classification. 3.Patients with reasonable oral hygiene. 4.Healthy patients without systemic diseases or local conditions that may interfere with bone healing except vitamin D insufficiency or deficiency

Exclusion criteria

Exclusion criteria: 1.Advanced or complicated implant cases. 2.Patients unable to follow the treatment protocol. 3.Patients lost during the study period. 4.Active infection or inflammation at the implant site. 5.Uncontrolled systemic diseases. 6.History of chemotherapy or radiotherapy.

Design outcomes

Primary

MeasureTime frame
Secondary implant stability Four months after implant placement Implant stability quotient measured by resonance frequency analysis using Osstell device

Secondary

MeasureTime frame
Primary implant stability Immediately after implant placement Implant stability quotient measured by resonance frequency analysis using Osstell device and insertion torque value

Countries

Iraq

Contacts

Public ContactNoor Fadhil

College of Dentistry University of Baghdad

noor.fadel2408m@codental.uobaghdad.edu.iq07702624675

Outcome results

None listed