Skip to content

Validity of the one-arm and two-arm functional reach test in individuals with stroke

Validity of the one-arm and two-arm functional reach test in measuring the limit of stability in standing in individuals with stroke

Status
Active, not recruiting
Phases
Unknown
Study type
Observational
Source
TCTR
Registry ID
TCTR20251124005
Enrollment
32
Registered
2025-11-24
Start date
2025-12-24
Completion date
Unknown
Last updated
2026-08-03

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Stroke population Stroke,Postural Balance,Functional Reach Test, Reliability, Validity

Interventions

Adults diagnosed with stroke in the subacute phase, confirmed by radiographic imaging.
Health Services Research
Stroke patients

Sponsors

Committee for Reviewing and Screening Quality Projects under the Pay-for-Performance Scheme ,Sirindhorn National Medical Rehabilitation Institute
Lead Sponsor

Eligibility

Sex/Gender
All
Age
18 Years to 70 Years

Inclusion criteria

Inclusion criteria: 1. Diagnosis of stroke (ischemic or hemorrhagic). 2. Able to stand independently without assistive devices. 3. Able to follow two-step verbal commands.

Exclusion criteria

Exclusion criteria: 1.Have other neurological disorders, such as Parkinson disease. 2.Have pain greater than 4/10 that affects standing or reaching. 3.Have visual impairments, ataxia, or dysmetria. 4.Have bilateral hemiparesis or significant limitation in shoulder or elbow movement. 5.Have vestibular dysfunction affecting balance. 6.Have hypoglycemia or abnormal blood pressure prior to participation.

Design outcomes

Primary

MeasureTime frame
Forward reach distance unsing one-arm functional reach test Measurements will be performed in two trials, and the average value will be used for analysis. Outcome was forward reach distance measured by the functional reach test with non paretic arm.,Forward reach distance unsing two-arm functional reach test Measurements will be performed in two trials, and the average value will be used for analysis. Outcome was forward reach distance measured by the functional reach test with two arm.

Secondary

MeasureTime frame
Anteroposterior COP displacement during one-arm functional reach test Measurements will be performed in two trials, and the average value will be used for analysis of validity. Anteroposterior center of pressure (COP) displacement was measured during the Functional Reach Test using the non-paretic arm, with a Zebris FDM-S force platform.,Anteroposterior COP displacement during two-arm functional reach test Measurements will be performed in two trials, and the average value will be used for analysis of validity. Anteroposterior center of pressure (COP) displacement was measured during the Functional Reach Test using the two-arm, with a Zebris FDM-S force platform.

Countries

Thailand

Contacts

Public ContactMr Pipat Klamruen

Sirindhorn National Medical Rehabilitation Institute

ptsnmrc22@gmail.com025915455

Outcome results

None listed

Source: TCTR (via WHO ICTRP) · Data processed: Aug 10, 2026