Skip to content

Effect of Dental Implant Design on Stability During Early Healing: A Randomised Controlled Trial.

Effect of Dental Implant Design on Stability During Early Healing: A Randomised Controlled Trial

Status
Active, not recruiting
Phases
Phase 2
Study type
Interventional
Source
TCTR
Registry ID
TCTR20230826014
Enrollment
70
Registered
2023-08-26
Start date
2023-09-10
Completion date
Unknown
Last updated
2026-08-03

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Patient with at least one lost tooth who requires an implant for dental replacement. Implant thread, implant designs, secondary stability, BLX implant, BL implant

Interventions

The operation will be performed. After BLX implant insertion, the insertion torque will be noted. The implant stability quotient (ISQ) and implant stability test (IST) values will be measured. ,The o
Experimental Device,Experimental Device
BLX implant,BL implant

Sponsors

Chulalongkorn University
Lead Sponsor

Eligibility

Sex/Gender
All
Age
20 Years to No maximum

Inclusion criteria

Inclusion criteria: 1. Healthy patients aged more than 20 years (ASA class I, II) 2. Patients have edentulous that was extracted/lost more than 2 months before operation day. 3. Adequate bone quality and quantity to place an implant and no history of acute infection at implant site. 4. Adequate good oral hygiene and can follow up post-op instruction.

Exclusion criteria

Exclusion criteria: 1. Patients who have jaw pathology. 2. Patients who wear orthodontic appliances. 3. Patients who have parafunctional habits (bruxism and clenching) 4. Patients who are smoking > 5 cigarettes per day or chewing tobacco. 5. Patients who have uncontrolled systemic diseases which compromise the bone healing process including Diabetes Mellitus and Osteoporosis. 6. Patients who have history of antiresorptive drug use and irradiation in head and neck area.

Design outcomes

Primary

MeasureTime frame
Implant stability intraoperative, 2 days, 1-6 weeks, 8 weeks, 12 weeks after surgery Implant Stability Quotient (ISQ) values

Secondary

MeasureTime frame
Implant stability intraoperative, 2 days, 1-6 weeks, 8 weeks, 12 weeks after surgery Implant stability test (IST) values

Countries

Thailand

Contacts

Public ContactRujira Charoenniwassakul

Faculty of Dentistry, Chulalongkorn University

vavavhanna@gmail.com0873509075

Outcome results

None listed

Source: TCTR (via WHO ICTRP) · Data processed: Aug 9, 2026