Skip to content

Gait performance evaluation using smart watch, smart band and smart phone comparing with wearable inertial system device in stroke patient

Gait performance evaluation using smart watch, smart band and smart phone comparing with wearable inertial system device in stroke patient

Status
Unknown
Phases
Unknown
Study type
Observational
Source
TCTR
Registry ID
TCTR20230404005
Enrollment
180
Registered
2023-04-04
Start date
2023-01-26
Completion date
Unknown
Last updated
2026-08-03

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Unilateral hemispherical stroke (ischemic or hemorrhagic) Stroke, Smart phone, Smart watch, Smart band, Step count, Gait velocity, Gait aid

Interventions

Group of patients who can ambulate with gait velocity less than 0.40 m/s with gait aid using,Group of patients who can ambulate with gait velocity less than 0.40 m/s without using gait aid,Group of pa
Device Feasibility,Device Feasibility,Device Feasibility,Device Feasibility,Device Feasibility,Device Feasibility
Household ambulator with gait aid patients,Household ambulator without gait aid patients,Limited community ambulator with gait aid patients,Limited community ambulator without gait aid patients,Commun

Sponsors

Individual fund
Lead Sponsor

Eligibility

Sex/Gender
All
Age
18 Years to No maximum

Inclusion criteria

Inclusion criteria: 1.Aged 18 or older 2.Diagnosed for unilateral hemispheric stroke (ischemic or hemorrhagic) at any onset (acute, subacute or chronic) 3.Ability to walk with FAC 3-5, with or without gait aid and/or ankle-foot orthoses 4.Ability to follow verbal instruction 5.Stable medical condition 6.Willing to join the study

Exclusion criteria

Exclusion criteria: 1.Additional neurological or psychiatric condition that affect ambulation 2.Additional orthopedic impairment in ambulation 3.Cerebellar ataxia 4.History of fall equal or more than 2 times in year 5.Adverse effects from walking test (eg. Fall, Clinical dyspnea)

Design outcomes

Primary

MeasureTime frame
Step count at enrollment smart watch, smart band, smart phone and wearable inertial system device

Secondary

MeasureTime frame
gait velocity at enrollment smart watch, smart band, smart phone and wearable inertial system device

Countries

Thailand

Contacts

Public Contactthanawat prugmahachaikul

Faculty of medicine, Chulalongkorn university

Premtham3@hotmail.com022564000

Outcome results

None listed

Source: TCTR (via WHO ICTRP) · Data processed: Aug 9, 2026