Skip to content

Impact of various implant designs to early stability of dental implant

Impact of various implant designs to early stability of dental implant

Status
Unknown
Phases
Phase 4
Study type
Interventional
Source
TCTR
Registry ID
TCTR20210628006
Enrollment
60
Registered
2021-06-28
Start date
2021-07-01
Completion date
Unknown
Last updated
2026-08-03

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Missing posterior tooth in healed site without need for bone augmentation (Type 4C by Gallucci et al 2018 ) BLX, Stability

Interventions

Bone level X implant with SLA surface,Bone level implant, SLA surface
Experimental Other,No Intervention Other
BLX implant SLA,Bone level implant

Sponsors

The International Team for Implantology (ITI)
Lead Sponsor

Eligibility

Sex/Gender
All
Age
20 Years to No maximum

Inclusion criteria

Inclusion criteria: 1. Subjects in need of dental implant placement for replacement of missing teeth. 2. Medically healthy (American Society of Anesthesiologists Classification I-II). 3. Age over 20 years old. 4. Healed implantation site grater than equal 2months 5. Adequate bone quality and quantity (including simultaneous bone augmentation) 6. Adequate bone height for implant length at least 8 millimeters 7. The insertion torque is equal to or more than 25 Ncm after implant placement.

Exclusion criteria

Exclusion criteria: 1. Medically compromised subjects (ASA classification III-V). 2. General contraindications against dentoalveolar surgery or augmentation procedures 3, Active drug therapy with drugs that may significantly affect bone metabolism or host-inflammatory responses, e.g. anti-resorptive agents, corticosteroid or immunosuppressive medications and non-steroidal anti-inflammatory drugs. 4. Medium and Heavy smoker (> 10 cigarettes per day) or recent heavy smoker (history of > 20 cigarettes/day within last 5 years) 5. Pregnant or intending to conceive 6. Subjects are not able/willing to consent for participation in the study.

Design outcomes

Primary

MeasureTime frame
Implant Stability Quotient values Implant placement day, 2 days, 1,2,3,4,5,6,8 week after implant placement Resonance frequency analysis

Secondary

MeasureTime frame
Implant stability test values Implant placement day, 2 days, 1,2,3,4,5,6,8 week after implant placement Anycheck

Countries

Thailand

Contacts

Public ContactAtiphan Pimkhaokham

Head of Department of Oral and Maxillofacial Surgery (OMFS) Faculty of Dentistry, Chulalongkorn University

atiphan.p@chula.ac.th08913080460

Outcome results

None listed

Source: TCTR (via WHO ICTRP) · Data processed: Aug 9, 2026