Skip to content

Rehabilitation with complete fixed prosthesis on implants by digital and conventional flow

Implant-supported fixed prosthesis rehabilitation made by digital and conventional workflow

Status
Recruiting
Phases
Unknown
Study type
Interventional
Source
REBEC
Registry ID
RBR-4kcvpb
Enrollment
Unknown
Registered
2020-01-22
Start date
2019-11-01
Completion date
Unknown
Last updated
2025-10-27

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Total edentulous

Interventions

A total of 17 patients with indication for rehabilitation with mandibular implant-supported fixed total denture will be divided into three groups of 5 or 6 patients each. All patients will receive fix
Device

Sponsors

Universidade Federal do Rio Grande do Norte
Lead Sponsor
Universidade Estadual de São Paulo
Collaborator

Eligibility

Age
18 Years to 85 Years

Inclusion criteria

Inclusion criteria: Edentulous in both arches; Both sexes; All patients should have been rehabilitated with conventional dentures at the Federal University of Rio Grande do Norte; users of new conventional dentures, with at least two (2) months of use and presenting the need for rehabilitation with a fixed implant supported prosthesis retained by four implants

Exclusion criteria

Exclusion criteria: Presence of these conditions: diabetes, smoking, osteoporosis and immunodeficiency; have undergone radiation therapy to the head and neck; be treated with some anticoagulant therapy

Design outcomes

Primary

MeasureTime frame
Passivity of infrastructures in implant-supported fixed total prosthesis made by digital workflow, verified through radiographic analysis and measurement via software.;Passivity of infrastructures for implant-supported fixed total prosthesis observed by means of radiographic analysis and measurement via software, verified by means of radiographic analysis and measurement via software, using the value of 150um as a mismatch parameter to indicate whether there is passivity and the interface between mini-pillar / infrastructure via radiography.

Secondary

MeasureTime frame
Precision and accuracy of intra-oral and extra-oral scanning - In Lab, verified from the measurement of the distance between implants. ;Accuracy and accuracy of intra-oral and extra-oral scanning, measured from the overlapping of the scanned physical models and analyzed for discrepancy in the positioning of the implants.

Countries

Brazil

Contacts

Public ContactAdriana da Fonte Carreiro

Universidade Federal do Rio Grande do Norte

adrianadafonte@hotmail.com+55(84)991284398

Outcome results

None listed

Source: REBEC (via WHO ICTRP)