Skip to content

Effect of electric and magnetic brain stimulation on physical performance

Effect of transcranial direct current stimulation and transcranial magnetic stimulation on physical performance

Status
Active, not recruiting
Phases
Unknown
Study type
Interventional
Source
REBEC
Registry ID
RBR-4jvybh
Enrollment
Unknown
Registered
2020-09-01
Start date
2017-11-23
Completion date
Unknown
Last updated
2025-10-27

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Exercise

Interventions

Transcranial direct current stimulation Before the constant load TTE test, individuals will receive either anodal HD-tDCS, anodal simulated conventional tDCS, or sham tDCS for 20 minutes. Participant
Brain Products, Munich, Germany). Each plastic casing will be filled with approximately 2 ml of HD-tDCS gel (Soterix Medical, New York, NY) to make contact between the electrode and the scalp. tDCS wi
Device
E02.331.750
E05.723.402

Sponsors

Universidade Federal do Rio Grande do Norte
Lead Sponsor
Universidade Federal do Rio Grande do Norte
Collaborator

Eligibility

Sex/Gender
Male
Age
18 Years to 50 Years

Inclusion criteria

Inclusion criteria: Aged from 18 to 50 years; take part in physical training with competitive purposes during the last six months; participate in endurance competitions; free from any cardiovascular, musculoskeletal, neurological or psychiatric disease; not taking any medication that could affect the central nervous system (citalopram, amphetamines, L-dopa, sulpiride, pergolide, lorazepam, rivastigmine, flunarizine and carbamazepine); not having contraindications for tDCS (not having metal implanted in the head, pacemaker, medical bumps, seizures, lesions on the scalp or head)

Exclusion criteria

Exclusion criteria: Impossibility to analyze the data due to data loss; injury; voluntary abandonment

Design outcomes

Primary

MeasureTime frame
Expected outcome 1 - It is expected to find an increase in physical performance with conventional and HD tDCS, evaluated by the time to exhaustion in a test in the cycle ergometer with fixed load at 80% of the maximum power reached in a progressive test of maximum effort, with a longer time compared to placebo condition;Outcome found 1 - There was no difference in time to exhaustion in a test on the cycle ergometer with a fixed load at 80% of the maximum power achieved in a progressive test of maximum effort between conventional and HD tDCS compared to placebo;Expected outcome 2 - It is expected to find an increase in physical performance with HD-tDCS, evaluated by the time to exhaustion in a test in the cycle ergometer with fixed load at 80% of the maximum power reached in a progressive test of maximum effort, with a longer time compared to conventional tDCS condition;Outcome found 1 - There was no difference in time to exhaustion in a test on the cycle ergometer with a fixed load at 80% of the maximum power achieved in a progressive test of maximum effort between conventional and HD tDCS

Secondary

MeasureTime frame
Expected outcome 4 - It is expected to find changes in the spectral power of the brain electrical activity, assessed using a 64-channel electroencephalogram, with increase in the spectral power of the frequency bands at rest in conventional and HD tDCS conditions as compared to the placebo condition ;Outcome found 4 - this outcome is still under analysis;Expected outcome 1 - It is expected to find a lower heart rate during exercise, assessed using a digital heart rate monitor, with lower values in submaximal intensities in conventional and HD tDCS conditions as compared to the placebo condition;Outcome found 1 - There was no difference in heart rate during exercise, assessed using a digital heart rate monitor, in any exercise intensity between conventional and HD tDCS compared to placebo;Expected outcome 2 - It is expected to find a lower ratings of perceived exertion, assessed using the Borg (6-20) perceived exertion scale, with lowed overall and for the legs perceived exertion in submaximal intensities in conventional and HD tDCS conditions as compared to the placebo condition;Outcome found 2 - There was no difference in ratings of perceived exertion, assessed using the Borg (6-20) perceived exertion scale, in any exercise intensity between conventional and HD tDCS compared to placebo;Expected outcome 3 - It is expected to find a lower percentage of associative thoughts during exercise, assessed using the Associative/dissociative thoughts scale (0-100%), with lower percentages of associative thoughts in submaximal intensities in conventional and HD tDCS conditions as compared to the placebo condition;Outcome found 3 - There was no difference in percentage of associative thoughts during exercise, assessed using the Associative/dissociative thoughts scale (0-100%), in any exercise intensity between conventional and HD tDCS compared to placebo

Countries

Brazil

Contacts

Public ContactDaniel Machado

Universidade Federal do Rio Grande do Norte

profdmachado@gmail.com+55 (84) 98160-5169

Outcome results

None listed

Source: REBEC (via WHO ICTRP)