Evaluation of the interference of peripherally placed deep venous access in the total volume of body water in newborns

Evaluation of the interference caused by the presence of a peripherally inserted central venous catheter in the Measurement of Resistance and Reactance with the use of Bioelectrical Impedance in newborns

Status
Active, not recruiting
Phases
Unknown
Study type
Interventional
Source
REBEC
Registry ID
RBR-3ctb9ry
Enrollment
Unknown
Registered
2023-03-30
Start date
2021-02-01
Completion date
Unknown
Last updated
2025-10-27

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Body composition

Interventions

This is a prospective, randomized, before-and-after study, in which resistance and reactance measurements measured before and after insertion of the peripherally inserted central venous catheter, whic
E02148224

Sponsors

Hospital Universitário Antônio Pedro - Universidade Federal Fluminense
Lead Sponsor
Hospital Universitário Antônio Pedro - Universidade Federal Fluminense
Collaborator

Eligibility

Age
No minimum to 28 Days

Inclusion criteria

Inclusion criteria: catheters inserted in the right upper limb

Exclusion criteria

Exclusion criteria: newborns with skin lesions where the electrodes were placed; newborn who inserted the catheter in a place other than the right upper limb

Design outcomes

Primary

MeasureTime frame
Expected outcome 1: Evaluate whether there is interference from the presence of a peripherally inserted central catheter in measuring resistance and reactance using the bioelectrical impedance method in newborns. The n-sample was calculated, taking into account a difference between the 44 averages of 5.0 ohms for reactance and 60.0 ohms for resistance, alpha error of 5%, beta error of 10% and significance of 95%. The calculated n-sample was 55 and research participants.;Outcome found 1: We observed a significant correlation between resistance (0.878) and reactance (0.765) values ??before and after PICC insertion. It is also observed that the higher the R and Xc values, the lower the correlation between the measurements, the clearer in relation to Xc, with greater dispersion between the highest values. It was expected that the values ??of R and Xc after insertion of the PICC would be higher, which was not evidenced.

Secondary

MeasureTime frame
No secondary outcomes expected

Countries

Brazil

Contacts

Public ContactHelen Valmont

Hospital Universitário Antônio Pedro - Universidade Federal Fluminense

helencvalmont@gmail.com+55 (21) 983948720

Outcome results

None listed

Source: REBEC (via WHO ICTRP)