Skip to content

Effectiveness of Photobiomodulation in Sensitivity to tooth Whitening in adults: randomized clinical trial.

Laser therapy applied for Sensitivity after tooth Whitening

Status
Active, not recruiting
Phases
Unknown
Study type
Interventional
Source
REBEC
Registry ID
RBR-3cbjq9
Enrollment
Unknown
Registered
2020-09-10
Start date
2019-10-07
Completion date
Unknown
Last updated
2025-10-27

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Dental hypersensitivity after office dental bleaching.

Interventions

Low-power laser therapy applied after office tooth whitening. 25 participants are part of the intervention and control groups. Photobiomodulation was done in 2 moments, immediately after bleaching and
Radiation
E02.594.540
E06.420.750

Sponsors

Universidade Federal do Amazonas - UFAM
Lead Sponsor
Universidade Federal do Amazonas - UFAM
Collaborator

Eligibility

Age
18 Years to 40 Years

Inclusion criteria

Inclusion criteria: At least canines with A2 or darker color and six superior anterior teeth free of restorations on the palatine and vestibular faces, healthy enamel and without pathological, physiological and drug alterations.

Exclusion criteria

Exclusion criteria: Volunteers with systemic diseases (metabolic, heart disease and immunological), oral condition with periodontal diseases. with orthodontic appliance, severe crowding, presence of intrinsic stains, using anti-inflammatory drugs, smokers, alcoholics, pregnant women or lactating women. Patients who reported strong or very strong sensitivity (scores from 3 to 4) of the 5-point Numerical Scale (NRS: 0 - no sensitivity, 1 - mild, 2 - moderate, 3 - strong and 4 - very strong) were also excluded.

Design outcomes

Secondary

MeasureTime frame
Effectiveness of office tooth whitening at different times of color evaluation maintained in the 2 research groups.;The results showed no statistically significant difference in relation to the color variation between the groups.

Primary

MeasureTime frame
The photobiomodulation protocol with a wavelength of 808 nm and a focal size of 0.028 cm², with a therapeutic dose activated at 0.10W power for 25 seconds at each point (50 seconds per tooth), with 2.5 J per energy point and 90 J / cm2 per point (180 J / cm2 per tooth), applied immediately and 24h after tooth whitening, did not decrease the intensity of tooth sensitivity after office tooth whitening.;Decreased intensity of tooth sensitivity after tooth whitening after photobiomodulation at different times of application, immediately and 24 hours after tooth whitening.

Countries

Brazil

Contacts

Public ContactGlenda Alencar

Universidade Federal do Amazonas - UFAM

glenda_alencar@hotmail.com+55-092-984420393

Outcome results

None listed