Skip to content

Evaluation of the Outcome of Osseodensification by Using Densah Burs and Bone Expanders in Cases of Posterior Mandibular Bone Atrophy A Randomized Controlled Study

Evaluation of the Outcome of Osseodensification by Using Densah Burs and Bone Expanders in Cases of Posterior Mandibular Bone Atrophy A Randomized Controlled Study

Status
Active, not recruiting
Phases
Phase 3
Study type
Interventional
Source
PACTR
Registry ID
PACTR202608673426442
Enrollment
8
Registered
2026-08-04
Start date
2021-05-01
Completion date
Unknown
Last updated
2026-09-14

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Oral Health

Interventions

Bone expander

Sponsors

Faculty Of Dentistry Suez Canal University
Lead Sponsor

Eligibility

Sex/Gender
All

Inclusion criteria

Inclusion criteria: Edentulous posterior mandibular ridge with alveolar buccolingual atrophy with a minimum dimension of 4-5.5 mm. Height of minimum 8mm. Bone quality of D2 or D3. Good oral hygiene Patients seeking fixed prostheses in the posterior mandibular region. Patients willing to have a surgical procedure follow-up with informed consent.

Exclusion criteria

Exclusion criteria: Medically compromised patients. Heavy smoker. Patients with local pathosis at the surgical site. Patients who received or lost implants at the surgical site.

Design outcomes

Primary

MeasureTime frame
CBCT was done immediately after placing the implant. Using Scanora 3Dx scanner CBCT machine. And for measurements were using OnDemand3D application immediately following implant placement for measuring the buccal bone thickness to the implant. ;initial stability were assessed immediately after implant placement with an Osstell® Mentor magnetic resonance device.;CBCT was done immediately after placing the implant. Using Scanora 3Dx scanner CBCT machine. And for measurements were using OnDemand3D application immediately following implant placement for measuring the bone density around the implant.;CBCT was done immediately after placing the implant. Using Scanora 3Dx scanner CBCT machine. And for measurements were using OnDemand3D application immediately following implant placement for measuring the crestal height to the implant.—

Secondary

MeasureTime frame
Stability was assessed after 4 months of implant placement with an Osstell® Mentor magnetic resonance device.;CBCT was done after 4 months. Using the Scanora 3Dx scanner CBCT machine. And for measurements, we were using the OnDemand3D application for measuring the bone density around the implant.;CBCT was done after 4 months. Using the Scanora 3Dx scanner CBCT machine. And for measurements, we were using the OnDemand3D application for measuring the crestal height to the implant.;CBCT was done after 4 months. Using the Scanora 3Dx scanner CBCT machine. And for measurements, we were using the OnDemand3D application for measuring the buccal bone thickness to the implant.—

Countries

Egypt

Contacts

Public ContactAsmaa Yousry

Assistant Professor of Oral and Maxillofacial Radiology at Suez Canal University

asmaa_yousry@dent.suez.edu.eg00201001974278

Outcome results

None listed

Source: PACTR (via WHO ICTRP) · Data processed: Sep 19, 2026