Skip to content

Gait patterns in patients with COPD during the 6-minute walk test

Gait patterns in patients with COPD during the 6-minute walk test - Gait patterns in COPD patients

Status
Active, not recruiting
Phases
Unknown
Study type
Observational
Source
NL-OMON
Registry ID
NL-OMON41654
Enrollment
300
Registered
2014-02-03
Start date
2014-02-21
Completion date
Unknown
Last updated
2024-06-11

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

chronic bronchitis Chronic Obstructive Pulmonary Disease (COPD) emphysema

Interventions

None listed

Sponsors

CIRO+, expertisecentrum voor chronisch orgaanfalen
Lead Sponsor

Eligibility

Age
18 Years to 99 Years

Inclusion criteria

Inclusion criteria: 1. Aged 40-85 years (COPD patiënts en controls age group 1) and aged 20-39 (controls age group 2). 2. Diagnosis of COPD according to GOLD guidelines (stage I-IV), only applicable for COPD patients. 3. Referral for assessment in CIRO+, and pulmonary rehabilitation in CIRO+ or CIRO+ rehabilitation network. 4. Subject is able to walk without walking aids. 5. Clinically stable evaluated by the physician.

Exclusion criteria

Exclusion criteria: 1. Neuromuscular co-morbidities 2. Subject is unable to walk without walking aids 3. Subject with open wounds 4. Medical history of asthma, lung cancer, sarcoidosis, tubercolosis, long fibrosis, or any other significant respiratory disease; having undergone lung surgery (e.g. lung volume reduction, lung transplantation); any clinical relevant disease which in the opinion of the investigator may influence the results of the study. 5. Other significant respiratory disease or chronic heart failure in controls.

Design outcomes

Primary

MeasureTime frame
- 6MWD - variability of Centre of Mass in medio-lateral direction

Secondary

MeasureTime frame
- Variability of Centre of Mass (COM) in anterior-posterior (COMAP) and vertical (COMV) direction - Centre of Pressure (COP) in medio-lateral, anterior-posterior and vertical direction, respectively COPML, COPAP, COPV - Average walking speed - Step length - Stride length - Cadence - Number of stops (assessed by D-flow software) - Lower-limb muscle strength and endurance (Biodex, Biodex Medical Systems Inc., New York, US) - Transcutaneous oxygen saturation during each 6MWT in hallway and on treadmill using a handheld pulse oximeter. - Borg scores of all 6MWT - Lung function using post-bronchospirometry - Resting ECG, evaluated by the physician - Body composition using DEXA - Balance using the TUG-test - 6MWD in hallway - While performing the 6MWT in the hallway and on the treadmill, the Minimod accelerometer (McRoberts, the Hague, the Netherlands; size 8.5x5.0x1.0 cm; weight 70 g) will be attached to the trunk at the height of the sacrum using an elastic belt. Matlab software (MathWorks, Eindhoven, the Netherlands) will be used to calculate step time, step length, acceleration intensity, cadence and acceleration amplitude variability.

Countries

Netherlands

Outcome results

None listed

Source: NL-OMON (via WHO ICTRP)