Bloodvessel deviations
Conditions
Interventions
30 Patients are randomly assigned to either standard or multiphasic protocol.
15 Patients undergo standard protocol, 15 patients undergo the multiphasic
protocol. The multiphasic protocol injects co
the total volume of contrast medium is injected is less (89 ml instead
of 100 ml). For research purposes low-dose scans will be made for an additional
20 seconds after the diagnostic scan is finishe
Sponsors
Jeroen Bosch Ziekenhuis
Eligibility
Age
18 Years to 99 Years
Inclusion criteria
Inclusion criteria: - Referred for CTA of the abdominal aorta according to clinical indications - Signed informed consent - > 18 years - Mentally competent - Kidney function > 60 GFR
Exclusion criteria
Exclusion criteria: - Kidney function
Design outcomes
Primary
| Measure | Time frame |
|---|---|
| - The amount of HU measured in the aorta at 30 positions from the celiac trunk to the iliac arteries in both groups. | — |
Secondary
| Measure | Time frame |
|---|---|
| - The contrast enhancement curve over time in the aorta in the multiphasic protocol. - The uniformity of the attenuation values of both protocols. - The volume of contrast medium that is used. - The clinical usefulness of the scans determined by 3 blinded radiologists (of whom one is not connected to the Jeroen Bosch Ziekenhuis) and scored at a scale from 1 to 3. | — |
Countries
Netherlands
Outcome results
None listed