Skip to content

Transfer from a serious game developed to train multi-articulated prosthesis use to actual multi-articulated prosthesis use.

Examining transfer of a skill trained in two virtual environments with different feedback on performance, to actual use of a myoelectrically controlled hand prosthesis with a specific focus on the ability of switching between grip modes and proportional control of the signal.

Status
Recruiting
Phases
Unknown
Study type
Interventional
Source
NL-OMON
Registry ID
NL-OMON24876
Enrollment
40
Registered
2017-03-21
Start date
2017-04-03
Completion date
Unknown
Last updated
2024-02-28

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Healthy volunteers, amputees, upper limb prosthesis

Interventions

This study is set up with a pre- posttest design with a 5 day training period in between. The participants will be divided into four groups. Depending on the group they will train with either a seriou

Sponsors

University Campus Fryslan, Revalidatiefonds Nederland
Lead Sponsor

Eligibility

Inclusion criteria

Inclusion criteria: The subjects included in this study are able bodied and right handed, with normal or corrected to normal vision. Both male and female subject will be included. All subjects included will be between 18 and 50 years of age.

Exclusion criteria

Exclusion criteria: Subjects with (history of) pain or musculoskeletal impairments of the arms or upper body will not be included. The same accounts for subjects with prior experience in the use of myoelectric devices and subjects younger than 18 or older than 50.

Design outcomes

Primary

MeasureTime frame
Primary outcome measure per test part; Serious game: Proportional: the error between required and produced velocity and the difference between the aperture of the virtual gripper and the diameter of three differently sized virtual balls. Discrete: Number of unsuccessful and successful switches, time needed to produce switch, and the type of command signal used to switch (hold-open, co-contraction, double puls). Displayed EMG signal: Proportional: The velocities of the left/right movement of a virtual platform at three different speeds (slow, intermediate and fast). The angle of the regression line through the three velocities will be determined. Discrete: Number of unsuccessful and successful switches. Time needed to produce switch. Prosthesis task: Duration of correctly re-placing a set of 6 clothespins. Primary outcome measure for pre- and posttest; Duration of correctly re-placing a set of 6 clothespins.

Secondary

MeasureTime frame
Secondary outcome measures; Serious game: Proportional: Duration of the plateau phase of the aperture of the gripper in the game. Accuracy of catching. Number of broken/missed/bounced objects. Discrete: x Displayed EMG signal: Proportional: x Discrete: time needed to produce switch. Prosthesis task: Proportional: Plateau time of hand opening Discrete: Number of unsuccessful and successful switches. All the above described measures will be ranked over participants per test. These ranks will be analyzed.

Contacts

Public ContactA. Heerschop

Center for Human Movement Sciences-UMCG, University of Groningen. Building-Room 3216-213

a.heerschop@umcg.nl+31 (0) 50 363 8902 // +31 (0) 6 44103626

Outcome results

None listed

Source: NL-OMON (via WHO ICTRP)