Skip to content

Ambulatory monitoring of postural instability and gait disorder in Parkinson's Disease.

Ambulatory monitoring of postural instability and gait disorder in Parkinson's Disease.

Status
Active, not recruiting
Phases
Unknown
Study type
Observational
Source
NL-OMON
Registry ID
NL-OMON23798
Enrollment
25
Registered
2009-10-17
Start date
2009-12-01
Completion date
Unknown
Last updated
2024-02-28

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Ambulatory moniotring Parkinson's Disease Kinematics PIGD

Interventions

None listed

Sponsors

Dr. J.P.P. van Vugt j.vanvugt@mst.nl Medisch Spectrum Twente Afdeling neurologie Postbus 50000 7500 KA Enschede +31 (0)53-487 2841 Dr. Ir. T. Heida Function: Assistant professor Biomedical Signals and Systems University of Twente Drienerlolaan 5 7522 NB Enschede Building: Zuidhorst 226 +31 (0)53 489 2759 S. Sharifi s.sharifi@student.utwente.nl MSc. Student Technical Medicine Medical Signalling +31 (0)53 4873064
Lead Sponsor

Eligibility

Inclusion criteria

Inclusion criteria: Parkinson patients, which are confirmed idiopathic PD diagnosis according to the UK Parkinson’s disease society criteria, in stages 1 to 4 in Hoehn and Yahr scale are recruited for the study. The patients must be able to walk independently without walking aids. The age-matched controle group will be able to walk without any visible gait problems.

Exclusion criteria

Exclusion criteria: 1. Impairments or diseases other than PD that affect gait or balance (e.g. orthopedic, neurological other than PD); 2. Inability to walk multiple short distances, together totaling approximately half an hour; 3. Dependent on walking aids; 4. Severe dyskinesia; 5. Uncorrected visual disturbance.

Design outcomes

Primary

MeasureTime frame
The subjects walk in a defined environment with six sensors and all activities will be filmed in order to correlate postural disability and gait disorders with the signals registrated by the sensors. The characteristics in gait are to be detected that cause PIGD and the corresponding signal. From this data several features are extracted that would be able to detect and classify PIGD. Furthermore, with the appointed features an optimal and minimal sensor configuration (amount and position of sensors) will be determined in which these features are still effective in detection and classification.

Secondary

MeasureTime frame
During the measurements also clinical tests are conducted (UPDRS 10 meter timed walking test + Timed-Up-and-Go), which give a clinical assessment of the stadium of the disease. The features that are derived from the sensors are correlated with the clinical scales.

Contacts

Public ContactJ.P.P. Vugt, van

Postbus 50000

j.vanvugt@mst.nl+31 (0)53-487 2841

Outcome results

None listed

Source: NL-OMON (via WHO ICTRP)