Skip to content

Iodine Starch Test Use in Pleuroperitoneal Leak

Practical Use of the Iodine Starch Test to Aid Diagnosis of Pleuroperitoneal Leak in Patients on Peritoneal Dialysis Using Icodextrin

Status
Not yet recruiting
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT07857564
Acronym
PIT-PLPD
Enrollment
30
Registered
2026-10-05
Start date
2026-12-01
Completion date
2027-12-01
Last updated
2026-10-26

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Peritoneal Dialysis, Peritoneal Dialysis (PD), Pleural Cavity Effusion, Hydrothorax

Keywords

Peritoneal dialysis, Icodextrin, Pleuroperitoneal leak, Pleural effusion, Hydrothorax

Brief summary

This is a study to see how a simple test can be used to check if fluid in the chest cavity contains starch. Some people with kidney failure have dialysis treatment by putting fluid in the tummy cavity, and sometimes the fluid can leak into the chest cavity. Iodine can change the colour of starch based dialysis fluid, so this test could be used to diagnose fluid leaking from the tummy cavity into the chest cavity. The investigators are doing this study to ensure the fluid doesn't change colour for other reasons.

Detailed description

This is a study involving adult patients who are already undergoing a pleural fluid drainage procedure as part of their routine clinical care. The study is based on the results of a laboratory proof of principle experiment which the investigators performed in the NUH BioResource and Research & Innovation Laboratory in November 2025, using non-clinical samples of standard peritoneal dialysis fluid to determine how much and what type of iodine is able to differentiate icodextrin from glucose or amino acid based peritoneal dialysis fluids. This has allowed the investigators to determine a clinical test in order to undertake an study of both non-dialysis patients who present to the pleural clinic (controls) and patients on peritoneal dialysis presenting with effusions to the renal unit, to ensure the iodine starch can be used in practice and that the test does not produce false positive results in patients with pleural effusions of other causes. The investigators will perform a control study in order to ensure that false positive results do not occur in pleural effusions of other causes. The investigators will consent 15 patients undergoing diagnostic or therapeutic pleural aspiration in the NUH pleural clinic. The sample size is an estimate based on the typical incidence of different pleural fluid types obtained in the NUH pleural clinic, and is expected to be sufficient to ensure we obtain samples of transudative, exudative and blood-stained effusion samples. The investigators will concurrently perform an study of patients on peritoneal dialysis who undergo diagnostic pleural aspiration (usually to investigate a possible pleuroperitoneal leak). The investigators will recruit five patients on peritoneal dialysis who present with pleural effusion to the Renal Home Therapies Unit. Up to five patients on peritoneal dialysis will also be recruited from two other UK centres. Potential participants will be identified by their usual clinical team when they attend the pleural clinic or renal service for a planned diagnostic or therapeutic pleural aspiration. Participants will consent for the investigators to collect 20mL of pleural fluid that is surplus to that required for clinical purposes. This will not require any changes to practice as it is standard clinical practice to remove larger volumes of fluid to relieve patients symptoms, and discard the waste fluid. The investigators add the pre-determined volume of Iodine and potassium iodide 2% (0.1mL) to 10mL of pleural fluid. The investigators will photograph the samples in the BioResource and Research & Innovation Laboratory using a standard iPhone camera on an NUH provided work iPhone, and then discard the samples. The remaining 10mL will be frozen at -80oCin the BioResource and Research & Innovation Laboratory to allow comparison of samples taken at different times, and reproducibility verification or collaborative validation with the other two renal units in the UK. Frozen samples will be kept for 2 years. Following consent patients will be allocated a study number and pseudonomysed for completion of CRF. The investigators will collect demographic data (age, sex) and relevant past medical history (chronic kidney disease, chronic obstructive pulmonary disease, diabetes, heart failure, ischaemic heart disease, hypertension)from each recruit, results of biochemical tests conducted in NUH laboratories as part of their standard care, and diagnostic information. Based on the outcome of the clinical study and the background laboratory studies the investigators will be able to validate recommendations about the volume and type of iodine needed to identify the presence of icodextrin in a pleural aspiration sample, which were demonstrated in the laboratory experiment.

Interventions

DIAGNOSTIC_TESTIodine tincture

Iodine and potassium iodide 2% (0.1mL)

Sponsors

Nottingham University Hospitals NHS Trust
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Adults (aged ≥18 years) attending for diagnostic or therapeutic pleural aspiration. * Able and willing to provide written informed consent for use of a small surplus pleural fluid sample for research purposes. * Sufficient pleural fluid volume (demonstrated on routine pre-procedure thoracic ultrasound scan) available to allow safe collection of at least an additional 10 mL sample without affecting routine clinical testing (clinical samples would require a minimum of 10mLs but common clinical practice is to remove larger volumes in in order to allow symptomatic relief).

Exclusion criteria

* Under 18 years of age. * Unable to give informed consent (e.g. due to cognitive impairment or lack of capacity).

Design outcomes

Primary

MeasureTime frameDescription
False positive results of iodine-starch test (blue-black colour change) when applied to pleural fluid samples from non-dialysis patients on a single sample at baselineBaselineTo assess whether the iodine-starch test produces any false positive results when applied to pleural fluid samples from non-dialysis patients on a single sample at baseline.
Positive Iodine-starch test (blue black colour change) in the pleural fluid of patients with a pleuroperitoneal leak using Icodextrin, on single baseline pleural fluid sampleBaselineTo assess whether the iodine-starch test can be used in practice to positively identify icodextrin in the pleural fluid of patients with a pleuroperitoneal leak on a single baseline pleural fluid sample.

Contacts

CONTACTJennifer C Allen, BMBS PHD
jennifer.allen36@nhs.net+44 01159627678

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Oct 27, 2026