Skip to content

Real-World Performance and Safety of Apneal Dx for Sleep Apnea Screening

Real-world Evaluation of the Clinical Performance and Safety of Apneal Dx for the Screening and Aid in the Diagnosis of Obstructive Sleep Apnea-hypopnea Syndrome in Adults: a Post-market Clinical Follow-up Study

Status
Not yet recruiting
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT07809633
Acronym
APNEAL-PMCF
Enrollment
400
Registered
2026-09-09
Start date
2026-09-01
Completion date
2031-06-01
Last updated
2026-09-09

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Obstructive Sleep Apnea, Sleep Apnea, Obstructive, Sleep Apnea Syndromes

Keywords

post-market clinical follow-up, real-world evidence, smartphone, software as a medical device, screening, apnea-hypopnea index, digital health

Brief summary

Sleep apnea-hypopnea syndrome (SAHS) is a frequent and largely under-diagnosed sleep-related breathing disorder. Adult prevalence is estimated between 9% and 38%. Untreated SAHS increases cardiometabolic and neurocognitive risk. Reference diagnostic methods (in-lab polysomnography and ambulatory ventilatory polygraphy) have limited capacity, which delays care. Apneal Dx is a Class IIa software as a medical device (CE-marked 10 June 2026). It measures cardiorespiratory sleep activity using the sensors of a standard smartphone worn on the chest, with no additional sensor, to screen for and aid in the diagnosis of adult obstructive sleep apnea-hypopnea syndrome at home. This study is a non-interventional, prospective, real-world post-market clinical follow-up (PMCF) of Apneal Dx used within its intended purpose in routine care. It does not add any examination, visit, randomisation or change to patient management. Data are collected from automatic device logs and optional in-app questionnaires completed by patients and healthcare professionals. The study covers France, Spain, Italy, the United Kingdom and Germany. There is no investigational site and no principal investigator.

Detailed description

OBJECTIVES This PMCF study addresses residual evidence gaps after CE marking of Apneal Dx, under MDR Articles 61(11), 83, 84 and 86 and Annex XIV Part B, in support of a strategy based on Article 61(10). Primary objectives: (A) Demonstrate end-to-end technical performance in the unsupervised home environment and detect safety-relevant failure modes. (B) Confirm concordance between the Apneal Dx AHI severity category and the healthcare professional's final clinical diagnosis obtained through the routine care pathway. (C) Quantify real-world false positive and false negative rates at AHI thresholds of 5, 15 and 30 events per hour. Secondary objectives: (D) Care-pathway time indicators (time to consultation, diagnosis and treatment). (E) How device outputs are used in clinical decisions. (F) Diagnostic performance against polysomnography (PSG) and ventilatory polygraphy (PG), when those tests have already been performed in routine care. (G) Real-world screening utility, conditions of use and usability. METHODS Design: observational, prospective, single-cohort, longitudinal real-world data collection. Non-comparative; no randomisation; no blinding; no imposed follow-up visit. Target enrolment: 400 evaluable patients (estimated). Individual participation lasts up to 24 months (questionnaires at 6, 12 and 24 months after the first recording). Study period: 04 September 2026 to 10 June 2031 (57 months, aligned with the CE certificate cycle). No intervention is assigned by the protocol. Apneal Dx is used under normal conditions of use and within its intended purpose. A PSG or PG result is collected only if the test has already been performed in the usual care pathway; the study never prescribes, prompts, schedules or funds a confirmatory test. Data sources: (1) automatic technical metadata from the device (session duration, signal quality, processing events, error codes, software version); (2) healthcare professional questionnaire (H01-H14) on the HCP web platform; (3) patient questionnaire (P01-P12) in the mobile application. No medical records, no SNDS, no biospecimens, no linkage with an external database. Setting: home and routine clinical practice. Decentralised collection with no investigational site, no participating institution and no principal investigator. The sponsor headquarters (Mitral SAS, Charenton-le-Pont, France) is declared as the single administrative location. Participants may reside in France, Spain, Italy, the United Kingdom or Germany. Ethics: no ethics committee is territorially or institutionally competent in the absence of a site. Human subjects protection review is therefore recorded as not required. Participation follows a dedicated in-app information notice, distinct from the terms of use, and a voluntary in-app agreement. A permanent right to object applies. Analysis: descriptive (point estimates and 95% Wilson confidence intervals, distributions, weighted Cohen kappa for concordance, sensitivity and specificity by AHI threshold, median delays). No superiority or non-inferiority hypothesis test. No multiplicity adjustment. Missing data are not imputed.

Interventions

None listed

Sponsors

Mitral
Lead SponsorINDUSTRY

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Aged 18 years or over * Uses Apneal Dx within its intended purpose in France, Spain, Italy, the United Kingdom or Germany * Has completed at least one recording generating a night report * Has received the study information notice * Has given the in-app agreement to take part

Exclusion criteria

* Under 18 years of age * Adult under legal protection Both

Design outcomes

Primary

MeasureTime frameDescription
Patient recording success rateContinuous, from study start through study completion (up to 57 months)Proportion of interpretable nights among all attempted recordings, derived from automatic device logging.
Concordance between Apneal Dx severity category and the physician's final clinical diagnosisUp to 24 months after the first recording, per participantWeighted Cohen's kappa and proportion of exact agreement between the AHI severity category produced by Apneal Dx (normal, mild, moderate, severe) and the final clinical diagnosis reported by the healthcare professional, in participants with a documented reference test (PSG or PG) obtained through routine care.
Real-world false positive and false negative rates by AHI thresholdUp to 24 months after the first recording, per participantFalse positive and false negative rates at AHI thresholds of 5, 15 and 30 events per hour, against the documented reference test result, with 95% Wilson confidence intervals.

Secondary

MeasureTime frameDescription
Time to consultationUp to 24 months after the first recordingMedian number of days between the Apneal Dx night report and the first consultation with a healthcare professional.
Time to diagnosisUp to 24 months after the first recordingMedian number of days between the Apneal Dx night report and the reference sleep test (PSG or PG) performed in routine care.
Time to treatmentUp to 24 months after the first recordingMedian number of days between the reference sleep test and treatment initiation.
Distribution of clinical decisions following the Apneal reportUp to 24 months after the first recordingDistribution of clinical decisions taken following the Apneal Dx report, by Apneal severity category.
Agreement with PSG and with ventilatory polygraphyUp to 24 months after the first recordingAgreement of Apneal Dx with PSG and with ventilatory polygraphy, stratified by reference test type and severity, in participants with a documented routine-care reference test.
Healthcare professional rating of Apneal Dx reliabilityUp to 24 months after the first recordingProportion of healthcare professionals rating Apneal Dx as reliable (score 4 or 5 on a 1-5 Likert scale).
Usability: navigation ease and instruction clarity6 months after the first recordingDistribution of navigation ease and instruction clarity scores (1-5 Likert scales) reported by patients.

Countries

France

Contacts

CONTACTGuillaume Cathelain
guillaume.cathelain@apneal.ai+33672448711
STUDY_DIRECTORGuillaume Cathelain

Mitral SAS

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Sep 10, 2026