Ankle Osteoarthritis, Foot Osteoarthritis, Joint Diseases, Osteoarthritis
Conditions
Keywords
SPECT/CT, Triphasic bone scan, Diagnostic accuracy
Brief summary
This cross-sectional study aims to assess the diagnostic accuracy of triphasic bone scintigraphy and SPECT/CT in evaluating foot and ankle osteoarthritis, using magnetic resonance imaging (MRI) as the reference standard, and to determine the affected joints.
Detailed description
Osteoarthritis of the foot and ankle is a significant cause of chronic pain and functional impairment. Conventional radiography has limited sensitivity for early changes, while magnetic resonance imaging (MRI) is considered the reference standard for evaluating cartilage, bone marrow edema, and soft tissue structures. Nuclear medicine techniques provide functional information about bone metabolism. Triphasic bone scan using technetium-99m methylene diphosphonate (99mTc-MDP) assesses perfusion, blood pool, and delayed skeletal uptake. However, planar imaging has limited spatial resolution and anatomical localization in the complex anatomy of the foot and ankle. Hybrid SPECT/CT combines the functional data of SPECT with the precise anatomical localization of CT, improving diagnostic confidence and specificity. This study will evaluate the diagnostic accuracy of triphasic bone scan and SPECT/CT compared with MRI in patients with suspected foot and ankle osteoarthritis.
Interventions
None listed
Sponsors
Study design
Eligibility
Inclusion criteria
Age ≥ 18 years * Patients presenting with chronic foot and/or ankle pain suspected to be due to osteoarthritis * Clinical and/or radiographic suspicion of foot or ankle osteoarthritis
Exclusion criteria
* Age \< 18 years * Previous surgery or joint replacement of the affected foot or ankle * Bone tumors or metastatic bone disease * Active osteomyelitis or septic arthritis * Inflammatory arthropathies (e.g., rheumatoid arthritis, psoriatic arthritis, gout)
Design outcomes
Primary
| Measure | Time frame | Description |
|---|---|---|
| Diagnostic accuracy of triphasic bone scan and SPECT/CT | Baseline | Sensitivity, specificity, positive predictive value, and negative predictive value of triphasic bone scintigraphy and SPECT/CT for detecting foot and ankle osteoarthritis, using MRI as the reference standard. |
Secondary
| Measure | Time frame | Description |
|---|---|---|
| Identification of affected joints | Baseline | Determination of the specific joints affected by osteoarthritis in the foot and ankle based on SPECT/CT and MRI findings. |
Contacts
assiut