Gentle Skin Abrasion and EMG-Based Neuromuscular Blockade Monitoring

Gentle Skin Abrasion and EMG-Based Neuromuscular Blockade Monitoring

Status
Completed
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT07759206
Enrollment
55
Registered
2026-08-12
Start date
2023-10-03
Completion date
2024-02-28
Last updated
2026-08-12

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Electromyography, Intraoperative Monitoring, Neuromuscular Blockade, Skin Preparation

Keywords

Gentle skin abrasion, Skin preparation, EMG monitoring, 3M Red Dot Trace Prep

Brief summary

This study will evaluate whether gentle skin abrasion improves electromyographic signal quality during neuromuscular blockade monitoring in adult surgical patients. Participants will receive standard TwitchView electromyographic neuromuscular blockade monitoring on one wrist and TwitchView monitoring after gentle skin abrasion on the opposite wrist. The study will compare electromyographic response amplitudes and supramaximal stimulus currents between routine electrode application and electrode application after skin preparation. The study procedures will occur during scheduled surgery and will not alter the anesthetic or surgical management of participants.

Detailed description

Neuromuscular blocking agents are commonly used during adult surgical procedures. Quantitative neuromuscular blockade monitoring is used to assess the effects of these drugs and to guide clinical management of neuromuscular blockade and recovery. The TwitchView electromyographic monitor is routinely used for this purpose and uses surface electrodes placed over the ulnar nerve and hand muscles to generate train-of-four measurements. In some patients, the electromyographic signal obtained with routine electrode application may be poor or inadequate for continuous monitoring. This may be related to skin condition, such as callouses, oily skin, or other factors that affect signal quality. Gentle skin abrasion is a technique commonly used in electrophysiology settings to improve the quality of physiologic electrical signals. This study will compare electromyographic signals obtained from routinely applied TwitchView electrodes with signals obtained from TwitchView electrodes placed after gentle skin abrasion using 3M Red Dot Trace Prep abrasive strips. After consent is obtained and the participant is moved into the operating room, TwitchView electrodes will be applied to both wrists. One wrist will receive routine electrode application without skin preparation, while the opposite wrist will undergo gentle skin abrasion before standard TwitchView electrodes are applied. Two TwitchView monitors will be used, one for each electrode strip. After induction of anesthesia, both TwitchView devices will be started. Other than a brief device start-up period, anesthetic and surgical management, including neuromuscular blocking drug dosing and timing, will be determined by the clinical care team and not by the investigators. The devices will record neuromuscular monitoring data during the procedure. The primary outcome is the amplitude of recorded electromyographic responses to train-of-four stimulation after induction of anesthesia but before administration of a paralytic drug. Secondary outcomes include the supramaximal stimulus current determined by the device and electromyographic signal amplitudes after administration of neuromuscular blocking drugs.

Interventions

PROCEDUREGentle Skin Abrasion Before EMG-Based Neuromuscular Blockade Monitoring

Gentle skin abrasion will be performed at the stimulus and recording electrode sites on one wrist using 3M Red Dot Trace Prep abrasive strips before applying standard TwitchView electrodes. The opposite wrist will receive routine electrode application without skin preparation. Two TwitchView monitors will be used to compare EMG signal amplitudes and supramaximal stimulus currents.

Sponsors

University of Minnesota
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Masking description

This is an open-label study. Study staff and clinical providers are aware of which electrode site receives routine application and which site receives gentle skin abrasion.

Intervention model description

All participants will receive standard EMG-based neuromuscular blockade monitoring on one wrist and EMG-based neuromuscular blockade monitoring after gentle skin abrasion on the opposite wrist. EMG signal amplitudes and supramaximal stimulus currents will be compared within participants.

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Adult surgical patient aged 18 years or older * Classified as American Society of Anesthesiologists Physical Status I, II, or III * Scheduled to undergo an elective procedure in which use of a neuromuscular blocking drug is anticipated * Neuromuscular blockade monitoring would be standard care for the planned procedure * Procedure allows access to both wrists * Capable of signing informed consent

Exclusion criteria

* Emergency procedure * Procedure in which neuromuscular blocking drugs are not anticipated * Access to at least one wrist and ankle is not possible * Unable to provide informed consent * Prior stroke * Hemiparesis or hemiplegia * Any other known neuromuscular disorder * Employee or student of the researcher * Pregnant women, fetuses, neonates, prisoners, children, or adults unable to consent

Design outcomes

Primary

MeasureTime frameDescription
EMG Response Amplitude Before Neuromuscular Blocking Drug AdministrationDuring surgery, before paralytic drug administrationAmplitude of recorded EMG responses to train-of-four stimulation will be compared between routine electrode application and electrodes placed after gentle skin abrasion.

Secondary

MeasureTime frameDescription
Supramaximal Stimulus CurrentDuring device startup after anesthesia inductionSupramaximal stimulus current determined by the TwitchView device will be compared between routine electrode application and electrodes placed after gentle skin abrasion.
EMG Response Amplitude After Neuromuscular Blocking Drug AdministrationDuring surgery, after paralytic drug administrationEMG signal amplitudes after administration of neuromuscular blocking drugs will be compared between routine electrode application and electrodes placed after gentle skin abrasion.

Countries

United States

Contacts

PRINCIPAL_INVESTIGATORMichael M Todd, MD

University of Minnesota

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Aug 13, 2026