Skip to content

Clinical Validation of an Artificial Intelligence System for De-termining Fetal Lie and Position in 3rd Trimester

Clinical Validation of an Artificial Intelligence System for Determining Fetal Lie and Position in 3rd Trimester

Status
Recruiting
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT07754071
Enrollment
150
Registered
2026-08-10
Start date
2025-09-11
Completion date
2026-10-01
Last updated
2026-08-10

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Breech Fetal Presentation, Cephalic Fetal Presentation, Fetal Presentation, Pregnancy

Keywords

fetal lie, fetal presentation, obstetric ultrasound, artificial intelligence, AI-assisted ultrasound, Navigation system, blind ultrasound sweep, third trimester pregnancy, clinical validation, Diagnostic accuracy, fetal orientation

Brief summary

This prospective clinical validation study aims to evaluate the diagnostic performance of an artificial intelligence (AI)-based navigational support system for determining fetal lie and presentation during third-trimester ultrasound examinations. Following routine clinical assessment by an expert clinician, three blind ultrasound sweeps will be obtained from each participant. The AI system will generate predictions of fetal lie and presentation from each sweep, which will be compared with the expert clinician's assessment as the reference standard. The study will also explore clinician perceptions of the system's usability and potential clinical value.

Detailed description

Accurate assessment of fetal lie and presentation during the third trimester is essential for obstetric management and delivery planning. Ultrasound is the gold standard for determining fetal orientation; however, the examination is highly operator-dependent and requires considerable experience to correctly identify fetal anatomy and orientation. Artificial intelligence (AI)-based navigational support systems have the potential to assist clinicians by providing real-time guidance during ultrasound examinations and improving the consistency of fetal orientation assessment. The purpose of this study is to prospectively validate an AI-based navigational support system for determining fetal lie and presentation during routine third-trimester ultrasound examinations. The system analyzes blind ultrasound sweeps acquired along the maternal midline and automatically predicts fetal lie and presentation. AI-generated predictions will be compared with expert clinician assessment, which serves as the reference standard. Eligible pregnant women attending third-trimester ultrasound examinations at the Fetal Medicine Department, Rigshospitalet, Slagelse - or Hillerød hospital, will be invited to participate. Following written informed consent, an expert clinician will first determine fetal lie and presentation as part of the routine ultrasound examination. The same clinician will subsequently acquire three blind ultrasound sweeps along the maternal midline. The AI navigational support system will analyze each sweep and generate predictions of fetal lie and presentation. All examinations will be completed within 5-10 minutes to minimize changes in fetal orientation between the clinical assessment and AI evaluation. The primary objective is to evaluate the diagnostic performance of the AI system by comparing AI-generated predictions with expert clinician assessment. Primary outcome measures include overall diagnostic accuracy and agreement, These findings will provide additional insight into the feasibility of implementing AI-assisted navigational support in routine obstetric ultrasound practice.

Interventions

None listed

Sponsors

Copenhagen Academy for Medical Education and Simulation
Lead SponsorOTHER
Rigshospitalet, Denmark
CollaboratorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
FEMALE
Age
18 Years to 70 Years
Healthy volunteers
No

Inclusion criteria

* Pregnant women aged ≥18 years. * Singleton pregnancy. * Gestational age ≥28+0 weeks. * Fetus in longitudinal lie (cephalic or breech presentation) as determined by the routine clinical ultrasound examination. * Able to understand Danish or English. * Able and willing to provide written informed consent.

Exclusion criteria

* Multiple pregnancy. * Fetus in transverse lie. * Inability to provide written informed consent.

Design outcomes

Primary

MeasureTime frameDescription
Diagnostic accuracy of the AI navigational support system for determining fetal lie and presentation.During the study ultrasound examination (approximately 5 minutes).Overall proportion of correct AI predictions of fetal lie and presentation compared with expert clinician assessment (reference standard).

Secondary

MeasureTime frameDescription
Agreement between AI predictions and expert clinician assessment.During the study ultrasound examination.Agreement will be evaluated using Cohen's kappa coefficient.

Countries

Denmark

Contacts

CONTACTMary Le Ngo, MD, MD
mary.van.anh.le.ngo.01@regionh.dk+45 20773779

Outcome results

None listed