Pupillary Dilation Reflex in Healthy Volunteers

The Relationship Between Neurostimulation Intensity and Pupillary Dilation Reflex (PRD) in Healthy Volunteers

Status
Recruiting
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT07746167
Enrollment
60
Registered
2026-08-04
Start date
2026-04-29
Completion date
2027-06-01
Last updated
2026-08-04

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Healthy Participants

Brief summary

This a single site, observational study that will examine how the pupil responds to neurostimulation under different conditions in healthy adults. The objective is to measure pupillary dilation reflex (PRD) in response to increasing neurostimulation intensities using the AlgometRx device.

Interventions

OTHERNo intervention (observational study)

No intervention

Sponsors

Children's National Research Institute
Lead SponsorOTHER

Study design

Observational model
CASE_ONLY
Time perspective
CROSS_SECTIONAL

Eligibility

Sex/Gender
ALL
Age
18 Years to 60 Years
Healthy volunteers
Yes

Inclusion criteria

* Age 18-60 years. * In good general health (self-reported). * Able and willing to provide written informed consent.

Exclusion criteria

* Eye pathology that prevents accurate pupillometry. * Pregnancy (Self-Report) * Diagnosis of autoimmune disorders. * Diagnosis of any neuropathic disorder * Inability to complete questionnaires.

Design outcomes

Primary

MeasureTime frameDescription
Pupillary Dilation Amplitude in Response to Increasing Neurostimulation Intensity Measured by AlgometRx Infrared PupillometerDay 1Pupillary dilation amplitude is defined as the maximum increase in pupil diameter from the pre-stimulus baseline, measured in millimeters (mm) using the AlgometRx infrared pupillometer. Pupil diameter is recorded before, during, and for 10 seconds following each 1-second stimulus. Amplitude is assessed at each stimulation intensity, beginning at 1.0 mA and increasing in 1 mA steps until participant perception, followed by measurements at 2 mA and 4 mA above the perception threshold, at each of three frequencies (5 Hz, 250 Hz, and 2000 Hz). Reported as the mean pupillary dilation amplitude in millimeters at each intensity and frequency combination.

Secondary

MeasureTime frameDescription
Baseline Pupil Diameter Variability During the Pre-Stimulation Period Measured by AlgometRx Infrared PupillometerDay 1Variability of pupil diameter recorded by the AlgometRx infrared pupillometer during the pre-stimulation baseline period, while participants fixate on a visual marker in a quiet room under controlled lighting for up to 5 minutes. Variability is calculated as the standard deviation of pupil diameter, in millimeters (mm), across the final 30 seconds of the baseline recording. Reported as the mean standard deviation in millimeters.
Area Under the Pupillary Dilation Curve (AUC) Measured by AlgometRx Infrared PupillometerDay 1Area under the curve (AUC) is calculated from the pupil diameter-time curve recorded over the 10-second period following each 1-second stimulus, using the AlgometRx infrared pupillometer, and is expressed in millimeter-seconds (mm\*s). AUC is assessed at each stimulation intensity, beginning at 1.0 mA and increasing in 1 mA steps until participant perception, followed by measurements at 2 mA and 4 mA above the perception threshold, at each of three frequencies (5 Hz, 250 Hz, and 2000 Hz). Reported as the mean AUC in millimeter-seconds at each intensity and frequency combination.
Difference in Pupillary Dilation Amplitude Between Ambient Lighting Conditions Measured by AlgometRx Infrared PupillometerDay 1Within-participant difference in pupillary dilation amplitude, measured in millimeters (mm) by the AlgometRx infrared pupillometer, between testing under approximately 100 lux and approximately 400 lux ambient lighting. Amplitude is defined as the maximum increase in pupil diameter from the pre-stimulus baseline. Reported as the mean within-participant difference in millimeters.
Inter-Ocular Agreement in Pupillary Dilation Amplitude Measured by AlgometRx Binocular Handheld AttachmentDay 1Agreement between left-eye and right-eye pupillary dilation amplitude recorded simultaneously using the AlgometRx binocular handheld attachment under identical stimulation and lighting conditions. Amplitude is defined as the maximum increase in pupil diameter from the pre-stimulus baseline, measured in millimeters. Agreement is expressed as an intraclass correlation coefficient (ICC) ranging from 0 to 1, where higher values indicate greater agreement between eyes. Reported as the ICC with a 95% confidence interval.
Percentage of Participants With Successful Simultaneous Binocular Pupillary Recording Using the AlgometRx Binocular Handheld AttachmentDay 1The percentage of participants in whom the AlgometRx binocular handheld attachment successfully captures interpretable simultaneous pupillary recordings from both eyes. A recording is considered successful if both pupils are tracked continuously throughout the stimulus and post-stimulus recording period. Reported as the percentage of participants with successful binocular recording.