Skip to content

Ultrasonographic Effects of Fascia Correction Kinesiotaping

Investigation of the Physiological Effects of Fascia Correction Kinesiotaping in Healthy Adults: An Ultrasonographic Study

Status
Completed
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT07703943
Enrollment
80
Registered
2026-07-15
Start date
2024-05-01
Completion date
2024-08-30
Last updated
2026-07-15

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Healthy

Brief summary

Single-center, within-subject repeated-measures study The aim of the present study was to investigate the acute effects of kinesiotaping applied using the fascia correction technique with different tension levels on fascial layers and associated musculature in healthy individuals. Outcome measurements. The primary outcome was the ultrasonographically measured thickness of the fascial layers, while secondary outcomes included the thickness of the superficial and deep flexor muscle layers and the subcutaneous tissue.

Detailed description

The fascial system plays an important role in force transmission, movement coordination, and interaction between musculoskeletal structures. Kinesiotaping is a commonly used therapeutic approach in rehabilitation, and the fascia correction technique has been proposed to influence fascial mobility and mechanical properties. However, the acute effects of different kinesiotape tension levels applied with the fascia correction technique on fascial and underlying musculoskeletal structures remain unclear.This single-center, within-subject repeated-measures study aims to investigate the immediate effects of kinesiotaping applied using the fascia correction technique with different tension levels on fascial layers and associated soft tissues in healthy individuals. Healthy volunteers aged 18 years or older will be included. Participants will undergo kinesiotape application with different tension levels according to the study protocol. Ultrasonographic assessments will be performed to evaluate changes in fascial layer thickness as the primary outcome. Secondary outcomes will include ultrasonographic measurements of superficial and deep flexor muscle thickness and subcutaneous tissue thickness. The study is designed to provide objective ultrasonographic measurements of acute tissue responses following kinesiotaping application and to improve understanding of the potential mechanical effects of the fascia correction technique on fascial and musculoskeletal structures.

Interventions

OTHERKinesiotaping

Fascia correction technique kinesiotaping

Sponsors

Haydarpasa Numune Training and Research Hospital
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
SCREENING
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 60 Years
Healthy volunteers
Yes

Inclusion criteria

A total of 80 healthy volunteers aged 18 years or older were included in the study. Participants had no current or previous serious musculoskeletal injury, pain, or neurological disorder affecting the upper extremity within the past six months

Exclusion criteria

Individuals were excluded if they were pregnant; regularly participated in high-level athletic training or competitive sports, had a history of skin allergy to adhesive materials; or had previous kinesiotaping application within the last month.

Design outcomes

Primary

MeasureTime frameDescription
The superficial antebrachial fascia thicknessBaseline and 30 minutes after two different interventions (different tensions). A one-week washout period was implemented between applicationsultrasonographic measurements were obtained from the dominant forearm at the mid-forearm level. the hyperechoic linear structure separating the subcutaneous tissue from the superficial flexor muscles was defined as superficial antebrachial fascia thickness
The deep antebrachial fascia thicknessBaseline and 30 minutes after two different interventions (different tensions). A one-week washout period was implemented between applicationsUltrasonographic measurements were obtained from the dominant forearm at the mid-forearm level. the hyperechoic linear structure separating the superficial and deep flxor muscles was defined as superficial antebrachial fascia thickness

Secondary

MeasureTime frameDescription
the subcutaneous tissue thicknessBaseline and 30 minutes after two different interventions (different tensions). A one-week washout period was implemented between applicationsSubcutaneous tissue thickness measured by B-mode ultrasonography (millimeters)
Forearm Superficial Flexor Muscle ThicknessBaseline and 30 minutes after two different interventions (different tensions). A one-week washout period was implemented between applicationsForearm superficial flexor muscle thickness measured by B-mode ultrasonography (millimeters)
Forearm deep flexor muscle thickness measured by B-mode ultrasonography (millimeters)Baseline and 30 minutes after two different interventions (different tensions). A one-week washout period was implemented between applicationsForearm deep flexor muscle thickness measured by B-mode ultrasonography (millimeters)

Countries

Turkey (Türkiye)

Contacts

STUDY_CHAIRElem Yorulmaz, Prof

Haydarpasa Numune Training and Research Hospital

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Jul 16, 2026