Radiographic Cortical Thickness of the Humerus in Detecting Post-Stroke Regional Bone Loss

Radiographic Cortical Thickness of the Humerus in Detecting Post-Stroke Regional Bone Loss

Status
Recruiting
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT07651306
Enrollment
65
Registered
2026-06-16
Start date
2026-02-22
Completion date
2026-07-01
Last updated
2026-06-16

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Dual Energy X-ray Absorptiometry, Hemiparesis After Stroke, Osteoporosis

Keywords

Stroke, Cortical Bone Thickness, Osteoporosis, Radiography

Brief summary

Post-stroke immobilization and reduced weight-bearing frequently lead to significant regional bone mineral density loss and asymmetry, particularly in the paretic upper extremity, which increases fracture risks. While Dual-Energy X-ray Absorptiometry (DXA) is the gold standard for evaluating systemic bone loss, it primarily focuses on axial or lower extremity sites and lacks universal accessibility. Since routine shoulder radiographs offer an opportunistic screening tool to evaluate regional bone quality without additional radiation , this study aims to compare proximal humerus cortical bone thickness between the paretic and non-paretic sides in stroke patients and assess its correlation with systemic DXA values to determine its clinical utility. This cross-sectional, observational study involves a retrospective data analysis of patients aged 18 and older who experienced a single unilateral stroke at least 6 months prior and present with clinical hemiparesis. Eligible participants must have concurrent standard anteroposterior shoulder radiographs and DXA measurements available from their routine clinical follow-ups. Patient demographic data, stroke characteristics, Brunnstrom stages, and systemic DXA measurements (femoral neck and lumbar spine T-scores and bone mineral density values) are systematically recorded for analysis. Cortical bone thickness measurements are performed using ImageJ software on standard radiographs at points 10 cm and 12 cm distal to the highest point of the humerus. To ensure reliability, measurements for both the paretic and non-paretic sides are conducted independently by two researchers who are completely blinded to the DXA results. Statistical analyses, including paired t-tests or Wilcoxon tests and Pearson or Spearman correlations, will be used to compare the sides and evaluate the relationship between radiographic cortical thickness and systemic bone density.

Detailed description

Background Post-stroke immobilization and reduced weight-bearing often lead to significant regional bone mineral density (BMD) loss and asymmetry, particularly in the paretic upper extremity, which increases fracture risks. While Dual-Energy X-ray Absorptiometry (DXA) is the gold standard for evaluating systemic bone loss, it primarily targets axial or lower extremity sites and may not be universally accessible in every clinical setting. Routine clinical imaging, such as standard shoulder radiographs, presents a valuable opportunistic screening tool to assess regional cortical bone quality without exposing patients to additional radiation. Objective The primary objective of this cross-sectional, observational study is to compare proximal humerus cortical bone thickness between the paretic and non-paretic sides in patients with stroke. Additionally, the study aims to evaluate the correlation between radiographic cortical thickness measurements and systemic DXA values to determine the clinical utility of standard X-rays in identifying post-stroke regional bone loss. Study Design and Methods This retrospective data analysis will include patients aged 18 and older with a history of a single unilateral stroke occurring at least 6 months prior, and presenting with clinical hemiparesis. Eligible participants must have concurrent standard anteroposterior shoulder radiographs and DXA measurements. Measurement Protocol: Cortical bone thickness (CBT) will be measured at 10 cm and 12 cm distal to the highest point of the humerus using standard radiographs via ImageJ software. Blinding: Measurements will be independently performed by two separate researchers who are completely blinded to the patients' DXA results. Comparison: The radiographic cortical thickness values from both paretic and non-paretic sides will be correlated and compared against femoral neck and lumbar spine (L1-L4) DXA T-scores and BMD values.

Interventions

None listed

Sponsors

Istanbul Physical Medicine Rehabilitation Training and Research Hospital
Lead SponsorOTHER_GOV

Study design

Observational model
CASE_ONLY
Time perspective
RETROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Patients aged 18 years and older. * A documented history of a single unilateral stroke that occurred at least 6 months prior to evaluation. * Presence of clinical hemiparesis. * Availability of concurrent standard anteroposterior (AP) shoulder radiographs taken within 6 months post-stroke alongside systemic DXA measurements.

Exclusion criteria

* History of surgical intervention in either shoulder. History of a proximal humerus fracture. * Co-existing metabolic bone diseases, such as primary hyperparathyroidism or osteomalacia. * History of malignancy. * Documented history of corticosteroid use. * Imaging artifacts that compromise the accuracy of DXA measurements. * History of a secondary stroke.

Design outcomes

Primary

MeasureTime frameDescription
Difference in Proximal Humerus Cortical Bone Thickness Between Paretic and Non-Paretic SidesBaselineThe average cortical bone thickness measured in millimeters on standard anteroposterior shoulder radiographs. Measurements are taken at exact locations 10 cm and 12 cm distal to the highest anatomical peak of the humerus on both the paretic and non-paretic sides to evaluate localized bone loss asymmetry.

Secondary

MeasureTime frameDescription
Correlation Between Radiographic Cortical Bone Thickness and Systemic Bone Mineral DensityBaselineThe correlation between the radiographic proximal humerus cortical thickness and systemic DXA values, specifically the bone mineral density (g/cm\^2) of the femoral neck and the lumbar spine.
Correlation Between Radiographic Cortical Bone Thickness and Systemic T-scoresBaselineThe correlation between the humerus cortical thickness measurements and systemic DXA T-scores to determine the clinical utility of standard X-rays in reflecting systemic osteopenia or osteoporosis classifications.