Skip to content

Closed Loop Glucose Control in a Simulated ICU Setting

Demonstration of an Expert Rule-Based Automated Insulin Delivery (AID) System for People With Type 1 and Type 2 Diabetes

Status
Not yet recruiting
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT07646067
Enrollment
6
Registered
2026-06-12
Start date
2026-07-01
Completion date
2027-12-01
Last updated
2026-06-12

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Stress Induced Hyperglycemia, Type 1 Diabetes, Type 2 Diabetes

Keywords

Artificial Pancreas, Intensive Care Unit, ICU, Closed Loop Glucose Control, Stress Induced Hyperglycemia, Type 1 Diabetes, Type 2 Diabetes, Inpatient, Hospital, Hypoglycemia, Hyperglycemia, Glucose Variability, Fully Autonomous

Brief summary

This is a proof of concept safety study of a rule-based closed loop glucose control system designed for use in the intensive care unit setting. The persons with type 1 and type 2 diabetes in this study will have their glucose controlled to a range of 100-140 mg/dL by a fully autonomous novel rule-based closed loop glucose control system for a period of 24 hours. The subjects will consume three standardized meals and receive a continuous intravenous infusion of dextrose (D-glucose) during the 24 hour study period. Meals will not be announced to the glucose control system.

Detailed description

Tight glucose control in the intensive care unit (ICU) setting is difficult to achieve. The investigators hypothesize that a closed loop glucose control system that is rule-based will improve upon the glucose control currently achieved by the current open loop manual methods, and that this improved glucose control may improve the outcomes of critically ill patients. This Earl Feasibility Study will test the ability of a prototype rule-based closed loop glucose control system named FUSION, to provide safe and effective glucose control in subjects with type 1 and type 2 diabetes in a clinical research center (CRC) setting. Subjects with type 1 diabetes have been chosen as safe and effective glucose control is difficult to achieve in these subjects during meal challenges. Subjects with type 2 diabetes have been chosen as they are insulin resistant, which makes their insulin resistance profile similar to that of ICU patients. As this is a safety study of a new medical device, the controlled environment of the CRC is preferable to the less controlled environment of an ICU setting. The prototype FUSION system to be used in this study will consist to two Dexcom G6 continuous glucose monitors (CGM), the rule-based glucose control software run on an all-in-one medical computer, and two syringe pumps. The prototype system is housed on a medical cart. Based on the average glucose value of the two Dexcom G6 CGM's, and the algorithms of the FUSION systems rule-based glucose control software, the FUSION system will make rate adjustments every 5-10 minutes to the intravenous infusion rates of short acting insulin (NovoLog) and dextrose (D10NS) under its control, in an attempt to keep the subjects glucose in the range of 100-140 mg/dL. The FUSION system only requires entry of the subjects study identification number and weight in kilograms to initiate the system. For safety reasons, the subjects will have their blood glucose independently measured every 10-60 minutes on the point of care Nova StatStrip system, throughout the 24 hour study period. The study has halting criteria to avoid recurrent instances of severe hypoglycemia (\< 54 mg/dL). The average of the two CGM's, that is used by the FUSION system for glucose control, will be used for statistical analysis.

Interventions

The FUSION system will be used to control the subjects glucose to a range of 100-140 mg/dL. Data will be collected for up to 24 hours, or upon early termination of the study session.

Sponsors

Ideal Medical Technologies
Lead SponsorINDUSTRY
National Institute of Diabetes and Digestive and Kidney Diseases (NIDDK)
CollaboratorNIH
Emory University
CollaboratorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Intervention model description

Early feasibility safety study

Eligibility

Sex/Gender
ALL
Age
18 Years to 70 Years
Healthy volunteers
No

Inclusion criteria

* Participants with type 1 and type 2 diabetes are eligible to be included in the study only if they meet all the following criteria: 1. Are 18-70 years of age, inclusive. 2. Can understand and sign an informed consent, communicate with the investigator, and understand and comply with the protocol requirements. 3. Have had a diagnosis of type 1 or type 2 diabetes for a period of at least 3 months. 4. Use insulin injections at home for glucose control. 5. Have a hemoglobin A1c (HbA1c) in the range of 7.0 - 10.0%. 6. Have a hemoglobin in the range for sex: 1. Females: 7-15.5 grams/dL. 2. Males: 7-17.5 grams/dl. 7. Have adequate venous access sites in upper extremities. 8. Body weight between 40 - 150 kg.

Exclusion criteria

1. Have participated in an interventional medical, surgical, or pharmaceutical study within 30 days of screening. 2. Have a known hypersensitivity to any of the components of study treatment. 3. Have skin disease/injury at Dexcom G6 CGM insertion site(s) that would prevent insertion of the CGM. 4. Currently abuses drugs or alcohol or has a history of abuse that in the investigator's opinion would cause the individual to be noncompliant. 5. Have a medical condition that in the opinion of the investigator could affect study participation and/or personal well-being. 6. Have a clinically significant history or presence of any of the following conditions: 1. Hepatic failure or has alanine aminotransferase (ALT) greater than 3 times the upper limit of normal. 2. Has an estimated GFR \<30 ml/min/1.73 m2 or End Stage Kidney Disease on renal replacement therapy. 3. Have congestive heart failure greater than class 1 on the NYHA classification system. 4. Have a history of seizures. 5. Have a history of cerebrovascular accident. 6. Have a history of ischemic heart disease. 7. For female subjects of potential childbearing age (age 18 to 55) they will be excluded if: 1. Pregnant. 2. Refuse to agree to a pregnancy test at the time of enrollment. 3. Have a positive urine pregnancy test at the time of enrollment. 8. Have a positive Influenza or COVID test within 14 days of visit 3. 9. Have any viral lower respiratory related symptoms (e.g., cough, chest tightness, respiratory distress) in the 14-day period prior to visit 3. 10. Have a known unprotected Influenza or COVID exposure in the 14-day period prior to visit 3. 11. Are currently being treated with Hydroxyurea, a medication which may cause the Dexcom G6 CGM to produce glucose readings that are higher than the actual glucose value.

Design outcomes

Primary

MeasureTime frameDescription
Primary Safety MeasureFrom beginning of use of the FUSION System to end of use of the FUSION System, which will be a period of time up to 24 hoursThe percentage of all glucose values \<70 mg/dL
Primary Efficacy MeasureFrom beginning of use of FUSION System to end of use of FUSION System, which will be a period of time of up to 24 hoursThe percentage of all glucose values within the glucose range of 70-180 mg/dL

Secondary

MeasureTime frameDescription
Percent of All Glucose Values Within Glucose Range <54 mg/dLFrom beginning of use of the FUSION System to end of use of the FUSION System, which will be a period of time of up to 24 hoursThe percentage of all glucose values that are less than 54 mg/dL
Percent of All Glucose Values Within Glucose Range 54-69 mg/dLFrom beginning of use of the FUSION System to end of use of the FUSION System, which will be a period of up to 24 hours.The percentage of all glucose values that are within the glucose range of 54-69 mg/dL
Number of Hypoglycemic Events (<70 mg/dL)From beginning of use of the FUSION System until end of use of the FUSION System, which will be a period of time of up to 24 hours.The total number of hypoglycemic events less than 70 mg/dL as measured by a continuous series of glucose values less than 70 mg/dL for at least 15 minutes duration.
Percent of All Glucose Values Within Glucose Range 70-100 mg/dLFrom beginning of use of FUSION System to end of use of FUSION System, which will be a period of time of up to 24 hoursThe percentage of all glucose values within the glucose range of 70-100 mg/dL
Percent of All Glucose Values Within Glucose Range 70-140 mg/dLFrom beginning of use of FUSION System to end of use of FUSION System, which will be a period of time of up to 24 hoursThe percentage of all glucose values within the glucose range of 70-140 mg/dL
Percent of All Glucose Values Within Glucose Range 100-140 mg/dLFrom beginning of use of FUSION System to end of use of FUSION System, which will be a period of time of up to 24 hoursThe percentage of all glucose values within the glucose range of 100-140 mg/dL
Percent of All Glucose Values Within Glucose Range >140 mg/dLFrom beginning of use of FUSION System to end of use of FUSION System, which will be a period of time of up to 24 hoursThe percentage of all glucose values greater than 140 mg/dL
Percent of All Glucose Values Within Glucose Range >180 mg/dLFrom beginning of use of the FUSION System to end of use of the FUSION System, which will be a period of time of up to 24 hoursThe percentage of all glucose values that are greater than 180 mg/dL
Percent of All Glucose Values Within Glucose Range >250 mg/dLFrom beginning of use of the FUSION System to end of use of the FUSION System, which will be a period of time of up to 24 hoursThe percentage of all glucose values that are greater than 250 mg/dL
Average glucose value in mg/dLFrom beginning of use of the FUSION System to end of use of the FUSION System, which will be a period of time of up to 24 hoursThe average of all measured glucose values in mg/dL
Measure of dispersion - Coefficient of VariationFrom beginning of use of FUSION System to end of use of FUSION System, which will be a period of time of up to 24 hoursThe Coefficient of variation of glucose will be calculated by dividing the standard deviation of the average glucose value by the average glucose value, then multiplying this value by 100.
Clarke Error Grid Analysis of Continuous Glucose Monitor DataFrom beginning of use of FUSION System to end of use of FUSION System, which will be a period of time of up to 24 hoursThe study data will be used to determine the percentage of the two Dexcom G6 CGM's glucose values in each zone using a Clarke error grid analysis. This same calculation will be performed on the average of the two Dexcom G6 CGM systems used by the FUSION system for purposes of glucose control.
FDA integrated Continuous Glucose Monitor StandardsFrom beginning of use of FUSION System to end of use of FUSION System, which will be a period of time of up to 24 hoursThe study data will be used to determine if each individual Dexcom G6 CGM system, and their average value meet FDA criteria for integrated Continuous Glucose Monitor (iCGM) accuracy for the glucose zones \<70 mg/dL, 70-180 mg/dL, and \>180 mg/dL.
Hemoglobin A1c Percentage LevelAs measured from a blood draw within two weeks prior to the start of the 24-hour closed loop glucose control sessionThe subjects hemoglobin A1c measurement from a blood draw taken within 2 weeks of the start of the closed loop glucose control session
C-Peptide LevelAs measured from a blood draw within two weeks prior to the start of the 24-hour closed loop glucose control sessionThe subjects C-peptide level will be measured prior to the start of the closed loop glucose control session.
Total Daily Dose of Insulin in Units/KilogramAs documented within two weeks prior to the start of the 24-hour closed loop glucose control sessionThe subjects total daily dose of insulin used prior to the start of the closed loop glucose control session was calculated by adding up all of the insulin doses used by the subjects (both short and long acting insulin) in units and dividing this value by the subjects weight in Kilograms
Weight in KilogramsAs measured just prior to the start of the 24-hour closed loop glucose control sessionAverage weight in kilograms of the subjects
Body Mass IndexAs measured just prior to the start of the 24-hour closed loop glucose control sessionThe body mass index will be calculated by dividing the subjects weight in kilograms by the square of their height in meters

Contacts

CONTACTLeon M DeJournett, MD
leondej@idealmedtech.com1-828-337-9960
CONTACTJeremy DeJournett, EE
jeremy@idealmedtech.com1-828-545-9110
STUDY_DIRECTORLeon M DeJournett, MD

Ideal Medical Technologies

PRINCIPAL_INVESTIGATORFrancisco Pasquel, MD, MPH

Emory School of Medicine

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Jun 13, 2026