Validate Smart Breath Analyzer as Screening Tool for Diabetic, Hepatic, Renal, Lung, and Other Metabolic Disorders

Early Identification of Metabolic Function Derangements Such as Diabetes, Liver, Renal Issues by Respyr Smart Breath Analyzer and Its Validation as a Screening Tool Among Diseased and Healthy Controls

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT07646015
Acronym
RESPYR-SBA
Enrollment
3000
Registered
2026-06-12
Start date
2022-10-03
Completion date
2023-10-05
Last updated
2026-06-12

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Diabetes Mellitus, Type 2, Healthy Volunteers, Kidney Diseases, Liver Diseases, Lung Diseases, Metabolic Diseases

Keywords

Breath analyzer, Exhaled breath analysis, Volatile organic compounds, Non-invasive screening, Metabolic disorders, Machine learning, Liver function, Kidney function, IoT health device, Point-of-care diagnostics

Brief summary

This is a prospective, multicentric, non-treatment study to build and validate a portable, non-invasive smart breath analyzer that can screen underlying health issues using exhaled breath. The study will be conducted with healthy participants and participants with known cases of diabetes, kidney related issues, liver related issues, and lung related issues as confirmed by pathology reports. In phase 1, 500 apparently healthy individuals with normal levels of fasting and postprandial blood sugar, renal function test, liver function test, and lung function test will be recruited. In phase 2, 500 patients of type 2 diabetes, liver function, renal function, and lung function derangements each diagnosed by 10% increment above normal values will be enrolled. In phase 3, validation of the breath analyzer as a screening tool for early identification of type 2 diabetes, liver, renal, lung and other metabolic function derangements will be done by randomly assigning healthy and diseased participants for exhaled breath sample analysis. The study is based on the principle of exhaled breath analysis where parts per million and parts per billion level of volatile organic compounds and gases in human breath will be measured. AI based algorithms will be generated to effectively screen unhealthy biomarker levels, enabling timely preventive action.

Detailed description

The smart breath analyzer, Respyr is an IoT and deep-tech enabled portable device developed by Humors Tech Pvt Ltd, Bangalore, India. The device measures volatile organic compounds (VOCs) and gases at parts-per-million and parts-per-billion levels in exhaled breath using AI and ML-based algorithms to identify metabolic derangements non-invasively. Registration Details: The study is registered with CTRI (CTRI/2022/09/045983) and ethics approval has been obtained from the Institutional Ethics Committee of JSS Medical College, Mysore (Ref: JSSMC/IEC/260822/07/CT Final Approval/2022-23, dated 19.12.2022). Protocol number: HTB-PROTOCOL-01, Version 1, dated 07 March 2022. Testing Procedure: Participants will provide an exhaled breath sample under fasting conditions, or with a minimum gap of 1 hour after consuming water and 3-4 hours after consuming food. The breath analyzer readings will be compared against standard laboratory diagnostic values including FBS/RBS, RFT, LFT, spirometry, and lipid profile, all tested within 15 days of participation. Regulatory Compliance: The study follows ICH-GCP guidelines, CDSCO-DCGI and New Drugs and Clinical Trial Rules 2019, and ICMR Ethical Guidelines for Biomedical Research on Human Participants.

Interventions

None listed

Sponsors

Respyr
Lead SponsorINDUSTRY
JSS Medical College Hospital
CollaboratorUNKNOWN

Study design

Observational model
CASE_CONTROL
Time perspective
CROSS_SECTIONAL

Eligibility

Sex/Gender
ALL
Age
18 Years to 75 Years
Healthy volunteers
Yes

Inclusion criteria

* Participant must either be a completely healthy individual as confirmed by blood examination, or a known case of diabetes, kidney disease, liver disease, and lung disease with relevant diagnostic reports tested within 15 days of participation * All genders and ethnicities * Age 18 to 75 years * Participant who has given informed consent * Participant must be fully vaccinated for COVID-19 * Participant must use the smart breath analyzer at fasting condition; if not fasting, minimum gap of 1 hour after water and 3-4 hours after food

Exclusion criteria

* Individual less than 18 or above 75 years of age * Pregnant and lactating females * Known case of ongoing illness such as Cancer, AIDS, COVID-19, Cough, Fever, TB, Chickenpox, Influenza, Mumps, or Tonsillitis * Individual who has not given informed consent

Design outcomes

Primary

MeasureTime frameDescription
Validation of Smart Breath Analyzer for Screening of Metabolic DisordersBaselineDevelopment and validation of an IoT and deep-tech enabled smart breath analyzer for accurate and early screening of metabolic derangements including diabetes, kidney disease, liver disease, lung disease, AI and ML-based algorithms will be generated to provide an affordable, non-invasive screening option enabling timely preventive healthcare action

Secondary

MeasureTime frameDescription
TriglyceridesbaselineMeasured in mg/dl. Normal range: \<150 mg/dl. Compared with smart breath analyzer readings.
HDLbaselineMeasured in mg/dl. Normal range: 40-60 mg/dl. Compared with smart breath analyzer readings.
VLDLBaselineMeasured in mg/dl. Normal range: 2-30 mg/dl. Compared with smart breath analyzer readings.
LDLBaselineMeasured in mg/dl. Normal range: 100-129 mg/dl. Compared with smart breath analyzer readings.
Cholesterol/ HDL RatioBaselineRatio with no unit. Normal range: \<4.5. Compared with smart breath analyzer readings.
LDL/HDL RatioBaselineRatio with no unit. Normal range: \<3. Compared with smart breath analyzer readings.
Serum Protein Level (Total Protein, Albumin, Globulin) assessed by Liver Function Test (LFT)BaselineMeasured in g/dl. Normal ranges: Total Protein 6.4-8.3 g/dl, Albumin 3.4-4.8 g/dl, Globulin 2-3.5 g/dl. Compared with smart breath analyzer readings.
Serum Creatinine Level assessed by Renal Function Test (RFT)BaselineMeasured in mg/dl. Normal range: 0.7-1.3 mg/dl. Compared with smart breath analyzer readings.
Fasting Blood Glucose Level assessed by Fasting Blood Sugar Test (FBS)BaselineMeasured in mg/dl. Normal range: 75-110 mg/dl. Compared with smart breath analyzer readings.
HBA1C (4.0-5.6)BaselineHbA1c Level assessed by Glycated Hemoglobin Test
Post Prandial (<140)BaselinePostprandial Blood Glucose Level assessed by Post Prandial Blood Sugar Test (PPBS)
Total/Direct/Indirect BilirubinBaselineSerum Bilirubin Level (Total, Direct, Indirect) assessed by Liver Function Test (LFT)
SGOT/AST (<37 U/L)BaselineSGOT/AST Level assessed by Liver Function Test (LFT
ALP (30-90 U/L)BaselineAlkaline Phosphatase (ALP) Level assessed by Liver Function Test (LFT)
Total Protein, Albumin, Globulin, A/G ratioBaselineSerum Protein Level (Total Protein, Albumin, Globulin, A/G Ratio) assessed by Liver Function Test (LFT)
Serum urea (13-43 mg/dl)BaselineSerum Urea Level assessed by Renal Function Test (RFT)
Uric acid (3.5-7.2 mg/dl)BaselineSerum Uric Acid Level assessed by Renal Function Test (RFT)
Calcium, PhosphorusBaselineSerum Calcium and Phosphorus Level assessed by Renal Function Test (RFT)
Sodium, Potassium, ChlorideBaselineSerum Electrolytes (Sodium, Potassium, Chloride) assessed by Renal Function Test (RFT)

Countries

India

Contacts

PRINCIPAL_INVESTIGATORNayanabai Shabadi, M.D

JSS Medical College, Mysore

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Jun 13, 2026