Skip to content

Radio-frequency (RF) Bladder Monitor

Radio-frequency (RF) Bladder Monitor

Status
Not yet recruiting
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT07639541
Enrollment
40
Registered
2026-06-10
Start date
2026-07-01
Completion date
2027-03-31
Last updated
2026-06-10

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Neurogenic Bladder (NB), Neurogenic Lower Urinary Tract Dysfunction, Spinal Cord Injuries (SCI)

Keywords

Spinal Cord Injury, Neurogenic Bladder, Neurogenic Lower Urinary Tract Dysfunction, Bladder Monitoring, Bladder Management, Microwave Sensing, Radio-Frequency Sensing, Wearable Medical Device, Bladder Fullness Detection, Bladder Volume Estimation, Non-Invasive Monitoring, Assistive Technology, Pilot Feasibility Study, Urology

Brief summary

The goal of this pilot feasibility study is to evaluate a wearable microwave (MW)-based bladder monitoring system in adult volunteers and those with spinal cord injury (SCI) who use self-catheterization for bladder management. The study aims to learn whether the device can monitor bladder filling and estimate bladder volume non-invasively. The main questions the study aims to answer are: 1. Can the MW-based monitoring system distinguish between non-full and full bladder states? 2. How accurately do MW-based bladder volume estimates agree with ultrasound bladder scans and voided urine volumes? 3. Is the wearable monitoring system feasible, comfortable, and usable for individuals with SCI? Participants will: 1. Complete questionnaires about bladder symptoms and quality of life 2. Wear up to six non-invasive MW sensors on the lower pelvic region 3. Undergo two bladder filling and voiding cycles during the study visit 4. Have MW measurements collected approximately every five minutes during bladder filling 5. Undergo ultrasound bladder scans and bladder volume measurements for comparison 6. Complete a post-study usability and comfort survey

Detailed description

Spinal cord injury (SCI) presents significant long-term challenges for affected individuals, among which bladder dysfunction is a leading concern. Neurogenic lower urinary tract dysfunction (NLUTD), commonly referred to as neurogenic bladder dysfunction, may result in urinary retention, incomplete bladder emptying, urinary incontinence, urinary tract infections (UTIs), bladder distension, urinary reflux, renal complications, and reduced quality of life. Current bladder management approaches, including clean intermittent catheterization (CIC), indwelling catheterization, and external collection methods, may be associated with substantial time burden, complications, excessive bladder filling or incomplete emptying, and poor adherence. Studies have also shown that improving bladder function remains one of the highest rehabilitation priorities among individuals with SCI. This study investigates the feasibility of a wearable radio-frequency (RF)-based bladder monitor operating in the microwave (MW) frequency range for non-invasive bladder monitoring and bladder volume estimation. The proposed system is intended to measure and track bladder volume and may ultimately support future development of discreet alerts indicating when the bladder is appropriately full and it is time to void. RF/MW sensing approaches provide several potential advantages for bladder monitoring applications because they are non-invasive, low-cost, safe for repeated use within established exposure limits, and compatible with wearable device designs. Previous computational and experimental studies investigating RF/MW approaches for bladder-state detection have demonstrated proof-of-concept feasibility; however, many earlier studies relied on simplified anatomical models and limited experimental conditions. More recent work by the investigators demonstrated bladder-state discrimination using realistic anatomical pelvic models and preliminary measurements in healthy volunteers. This study includes measurements in both healthy volunteers and individuals with SCI who self-catheterize. The objectives of the study are: i) to provide a clinical proof-of-concept demonstration of MW bladder monitoring and bladder volume quantification; and ii) to provide data regarding the short-term functionality, utility, and comfort of the wearable MW bladder monitoring prototype. The study will enroll adult healthy volunteers and adult participants with SCI who use self-catheterization for bladder management. Following informed consent, participants with SCI may complete questionnaires related to bladder dysfunction and bladder-related quality of life, including the Neurogenic Bladder Symptom Score Short Form (NBSS-SF). Participants will undergo bladder filling and voiding cycles during the study visit. At the beginning of the session, participants will be asked to void their bladder using their usual voiding or catheterization method. For participants in whom pregnancy is possible, urine pregnancy testing may be performed prior to RF measurements. Ultrasound bladder scans will be performed at empty and full bladder states and will serve as reference measurements for bladder volume estimation. Voided urine volumes will also be collected during voiding phases. The MW bladder monitoring prototype will be placed externally on the lower pelvic region by study personnel. Up to six sensors may be used. Sensors will be secured using adhesive bandages or wrap-style fixation methods. No skin preparation, gels, or invasive procedures are required. MW measurements will be collected automatically approximately every five minutes while the bladder fills naturally. Participants may rest or perform sedentary activities during the measurement period. Measurements will continue until bladder fullness is reached or the participant requests to void. The bladder filling and emptying process may then be repeated for a second cycle during the same study visit. Collected MW measurement data will be analyzed to investigate signal trends and the feasibility of the technology. Planned analyses include: * Bladder fullness classification through comparison of MW signal trends between non-full and full bladder states; * Bladder volume quantification using raw measurement data and reconstructed radar image data; * Comparison of MW-based bladder volume estimates with ultrasound-estimated bladder volumes and voided urine volumes. Exploratory analyses will evaluate signal trends across the measured frequency range to select optimal frequency points, measurement variability, and sex-based differences in MW measurements. Participant and clinician feedback surveys will additionally be used to assess device comfort, usability, and utility for bladder monitoring applications. As a final remark, this pilot feasibility study is intended to generate preliminary clinical data supporting further development and optimization of wearable MW bladder monitoring technology and may support future larger clinical investigations aimed at improving bladder management for individuals living with bladder dysfunction, including neurogenic bladder associated with SCI. The investigational device is considered low risk. The device is non-invasive and uses low-power RF/MW signals for sensing and monitoring purposes only.

Interventions

DEVICEWearable microwave Bladder Monitoring System

The investigational device is a non-invasive wearable microwave (MW) bladder monitoring system designed to monitor bladder filling and estimate bladder volume. The system uses low-power radio-frequency (RF) signals and externally applied sensors positioned over the lower pelvic region to collect electromagnetic measurements associated with bladder filling. Measurements will be collected approximately every five minutes during natural bladder filling cycles. The device is intended for investigational use only and does not provide therapeutic intervention or automated clinical decision-making.

Sponsors

McGill University Health Centre/Research Institute of the McGill University Health Centre
Lead SponsorOTHER
Congressionally Directed Medical Research Programs
CollaboratorFED

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
OTHER
Masking
NONE

Intervention model description

The study will include 40 participants: 20 healthy volunteers and 20 patients. All participants will undergo the same protocol.

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

* Age \> 18 * Able/willing to sit (or stand) in place for the time it takes for bladder to fill once. * No implanted devices * Able to toilet/void independently * No pregnancy

Exclusion criteria

* Age \< 18 * Implanted devices (e.g., pacemakers) * Unable to toilet without assistance * Unable to stay relatively still for the time it takes bladder to fill once * Pregnancy

Design outcomes

Primary

MeasureTime frameDescription
Mean difference in microwave S-parameter magnitude between full and empty bladder states (dB)Through study completion, an average of 4-8 hoursMicrowave S-parameter measurements collected during bladder filling and voiding cycles will be compared between empty and full bladder states. The outcome will be reported as the mean difference and standard deviation in S-parameter magnitude between full and empty bladder states across the measured frequency range, expressed in decibels (dB).
Mean error of microwave-based bladder volume estimation (mL) relative to ultrasound bladder volume estimates and voided urine volumeThrough study completion, an average of 4-8 hoursBladder volume estimates derived from microwave S-parameter measurements will be compared with ultrasound bladder volume estimates and voided urine volumes obtained during bladder filling and voiding cycles. The outcome will be reported as the mean difference and standard deviation between microwave-based bladder volume estimates and the corresponding reference measurements (mL).

Secondary

MeasureTime frameDescription
Total score on the investigator-developed post-participation bladder monitor questionnaireDay 1Participant perceptions of comfort, usability, and utility of the wearable microwave-based bladder monitoring system will be assessed using an investigator-developed post-participation questionnaire. Total scores range from 1 to 10, with higher scores indicating greater comfort, usability, and perceived utility of the device.
Frequency points exhibiting the greatest difference in microwave S-parameter magnitude between full and empty bladder states (MHz)Through study completion, an average of 4-8 hoursFor each participant, differences in microwave S-parameter magnitude between full and empty bladder states will be calculated across the 500-3000 MHz frequency range. The outcome will identify the frequency points and frequency ranges exhibiting the largest bladder-state-dependent signal differences. Analyses will be performed for the overall cohort and separately for male and female participants to assess sex-based differences in optimal frequency selection.

Countries

Canada

Contacts

CONTACTEmily Porter, Ph.D.
emily.porter@mcgill.ca514-934-1934
CONTACTLysanne Campeau, Ph.D.
lysanne.campeau@mcgill.ca514-340-8222
PRINCIPAL_INVESTIGATOREmily Porter, Ph.D.

McGill University

PRINCIPAL_INVESTIGATORLysanne Campeau, Ph.D.

McGill University

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Jun 11, 2026