Skip to content

Low-Dose Rocuronium Maintenance During Spine Surgery With Intraoperative Neurophysiological Monitoring

A Randomized Controlled Trial Comparing Low-Dose Rocuronium Maintenance Versus Discontinuation After Induction on Motor Evoked Potential Quality During Spine Surgery With Intraoperative Neurophysiological Monitoring

Status
Not yet recruiting
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT07627750
Acronym
ROC-IONM
Enrollment
62
Registered
2026-06-04
Start date
2026-06-01
Completion date
2028-12-01
Last updated
2026-06-04

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Intraoperative Neurophysiological Monitoring, Neuromuscular Blockade, Spine Surgery

Keywords

Rocuronium, Motor Evoked Potentials, Somatosensory Evoked Potentials, Train-of-Four Ratio, Spine Surgery, Intraoperative Neurophysiological Monitoring, Total Intravenous Anesthesia

Brief summary

This randomized controlled trial will compare two strategies for rocuronium use during general anesthesia for spine surgery with intraoperative neurophysiological monitoring. Participants undergoing spine surgery under general anesthesia with motor evoked potential and/or somatosensory evoked potential monitoring will be randomized to either low-dose rocuronium maintenance targeting a train-of-four ratio of 0.60 to less than 0.90, or no rocuronium maintenance after induction. The main objective is to compare the effects of these two strategies on the quality of intraoperative neurophysiological monitoring, especially motor evoked potential signals. Secondary objectives include comparing surgical field conditions, unwanted patient movement, emergence and extubation times, early respiratory events, and new postoperative neurological deficits. The study will be conducted at the Center for Anesthesia and Surgical Intensive Care, Bach Mai Hospital, Hanoi, Vietnam. The planned sample size is 62 participants, with 31 participants in each group.

Detailed description

Intraoperative neurophysiological monitoring is commonly used during complex spine surgery to help detect early neurological injury. Motor evoked potentials are particularly sensitive to neuromuscular blockade. Avoiding maintenance neuromuscular blockade may improve motor evoked potential signal quality, but may increase the risk of unwanted patient movement and suboptimal surgical field conditions. Conversely, low-dose rocuronium maintenance may improve surgical conditions, but may reduce motor evoked potential amplitude if neuromuscular blockade is excessive. This trial will evaluate whether low-dose rocuronium maintenance, titrated by quantitative neuromuscular monitoring, can preserve intraoperative neurophysiological monitoring quality while improving surgical field conditions compared with discontinuation of rocuronium after induction. All participants will receive standardized total intravenous anesthesia with propofol-based maintenance, bispectral index monitoring, quantitative train-of-four monitoring, and intraoperative neurophysiological monitoring. Rocuronium will be administered for tracheal intubation in both groups. In the low-dose maintenance group, rocuronium will be titrated to maintain a train-of-four ratio from 0.60 to less than 0.90. In the no-maintenance group, no additional rocuronium will be given after induction unless predefined safety rescue is required. The primary outcome will be intraoperative motor evoked potential signal quality, including mean motor evoked potential amplitude. Secondary outcomes will include successful motor evoked potential recording, motor evoked potential warning events, somatosensory evoked potential stability, surgical field condition, unwanted patient movement, time to emergence, time to extubation, early postoperative respiratory events, and new postoperative neurological deficits.

Interventions

DRUGLow-Dose Rocuronium Maintenance

Rocuronium will be administered for tracheal intubation and then maintained at a low dose during surgery. The infusion will be titrated according to quantitative train-of-four monitoring to maintain a train-of-four ratio from 0.60 to less than 0.90.

DRUGRocuronium

Rocuronium will be administered only for tracheal intubation during induction of anesthesia. No maintenance rocuronium will be administered after induction, except for predefined safety rescue if clinically necessary.

Sponsors

Bach Mai Hospital
Lead SponsorOTHER
Hanoi Medical University
CollaboratorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
SINGLE (Outcomes Assessor)

Masking description

The anesthesia team will not be masked because they administer and titrate rocuronium according to group assignment. The intraoperative neurophysiological monitoring assessor and the data analyst will be masked to group allocation when feasible.

Intervention model description

Participants will be randomized in a 1:1 ratio to one of two parallel groups: low-dose rocuronium maintenance targeting a train-of-four ratio of 0.60 to less than 0.90, or no rocuronium maintenance after induction.

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

\- 1. Patients aged 18 years or older. 2. Patients scheduled for spine surgery under general anesthesia. 3. Patients undergoing spine surgery with intraoperative neurophysiological monitoring, including motor evoked potentials and/or somatosensory evoked potentials. 4\. Patients who agree to participate in the study and provide written informed consent.

Exclusion criteria

* 1\. Pre-existing central or peripheral neurological disease that may affect intraoperative neurophysiological monitoring, such as quadriplegia, persistent sensory disorder, sequelae of stroke, or polyneuropathy. 2\. History of epilepsy or electroencephalographic disorder. 3. Use of neuropsychiatric drugs, strong sedatives, or drugs affecting neuromuscular or neurological conduction within 48 hours before surgery. 4\. Decompensated cardiovascular disease or severe respiratory disease that may affect emergence or anesthetic drug metabolism. 5\. Contraindication to intraoperative neurophysiological monitoring. 6. Contraindication to rocuronium. 7. Refusal to participate or withdrawal of consent at any time..

Design outcomes

Primary

MeasureTime frameDescription
Mean Intraoperative Motor Evoked Potential AmplitudeFrom baseline intraoperative neurophysiological monitoring after patient positioning to the final intraoperative neurophysiological monitoring recording before wound closureMean intraoperative motor evoked potential amplitude, measured in microvolts, recorded from predefined target muscles during spine surgery. The mean of three consecutive technically acceptable responses will be used at standardized intraoperative time points after stabilization of anesthesia and physiologic parameters.

Secondary

MeasureTime frameDescription
Successful Motor Evoked Potential RecordingDuring surgeryProportion of participants with successful intraoperative motor evoked potential recording from at least one predefined target muscle.
Motor Evoked Potential Warning EventsDuring surgeryNumber of intraoperative motor evoked potential warning events, defined as a decrease of 50 percent or more in amplitude from baseline lasting more than 5 minutes and not attributable to surgical manipulation after correction of physiologic and technical factors.
Surgical Field ConditionDuring surgerySurgical field condition assessed using the Leiden-Surgical Rating Scale, ranging from 1 to 5, with higher scores indicating better surgical conditions.
Unwanted Patient MovementDuring surgeryOccurrence and number of unwanted patient movement events that affect surgical manipulation or require anesthetic or neuromuscular blockade adjustment.
Time to ExtubationFrom discontinuation of maintenance anesthesia to tracheal extubationTime from discontinuation of maintenance anesthetic infusion to safe tracheal extubation, measured in minutes.
New Postoperative Neurological DeficitPost-anesthesia care unit and 24 to 48 hours after surgeryOccurrence of new postoperative motor or sensory neurological deficit assessed in the post-anesthesia care unit and within 24 to 48 hours after surgery.
Somatosensory Evoked Potential StabilityDuring surgeryProportion of intraoperative monitoring time without significant somatosensory evoked potential changes, defined as latency increase of 10 percent or more or amplitude decrease of 50 percent or more from baseline lasting more than 5 minutes and not attributable to surgical manipulation.
Time to EmergenceFrom discontinuation of maintenance anesthesia to eye opening on verbal commandTime from discontinuation of maintenance anesthetic infusion to eye opening on verbal command, measured in minutes.
Early Postoperative Respiratory EventsDuring emergence and within 60 minutes after arrival in the post-anesthesia care unitOccurrence of early respiratory events, including oxygen desaturation below 92 percent, laryngospasm, bronchospasm, sputum obstruction, or delayed extubation due to respiratory muscle weakness.

Contacts

CONTACTDuc Minh Tran, MD
tdminh1312@gmail.com84869319291
PRINCIPAL_INVESTIGATORToan Thang Nguyen, MD, PhD, Associate Professor

Hanoi Medical University

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Jun 5, 2026