Skip to content

CLIKX® Tympanostomy Tube Delivery System for the Placement of Tympanostomy Tubes

A Prospective Clinical Study of the Clikx Tympanostomy Tube Delivery System for Patients Requiring the Placement of Tympanostomy Tubes

Status
Recruiting
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT07625657
Enrollment
80
Registered
2026-06-04
Start date
2026-07-07
Completion date
2027-08-01
Last updated
2026-09-11

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Otitis Media, Otitis Media Chronic, Otitis Media Effusion, Otitis Media in Children, Otitis Media Recurrent

Keywords

otitis media, Tympanostomy tube, NousQ, CLiKX, myringotomy

Brief summary

This study looks at the safety and performance of the CLiKX device. The device is used to place ear tubes (also called ventilation tubes) in children and adults. These tubes help treat chronic ear fluid (otitis media with effusion) and other conditions where a doctor decides an ear tube is needed. In this study, surgeons will use the CLiKX device to place an ear tube in the patient's ear. The study will check if the surgeon can place the tube correctly in the right position. The procedure will first be attempted with no anesthesia or with local anesthesia. If needed, the surgeon may then use mild sedation or general anesthesia. The study will also look at how well patients tolerate the procedure by checking for side affects during the procedure. Finally, the study will look at how the device affects the procedure and patient safety. Researchers will review how the procedure is performed and will follow patients for up to 30 days after the procedure to continue to check for any side effects..

Detailed description

This is a prospective, single-arm, multicenter study designed to evaluate the safety and effectiveness of the CLiKX device for the placement of tympanostomy tubes in pediatric and adult patients undergoing tympanostomy tube insertion for the treatment of chronic otitis media or other conditions requiring tympanostomy tube placement. Eligible participants include children and adults ≥6 months of age who are scheduled to undergo tympanostomy tube insertion and have an ear canal diameter ≥4 mm. The primary objective of the study is to evaluate procedural success (effectiveness), defined as successful incision of the tympanic membrane (myringotomy) and delivery of the tympanostomy tube into the intended position, while minimizing device-related adverse events during the procedure (safety). Secondary objectives include the assessment of safety through 30 days post-procedure, as well as evaluation of procedural workflow and device performance. Participants will complete study visits at the following time points: Baseline, Tympanostomy Procedure Visit, Post-Tympanostomy Procedure Visit (at discharge), and a 30-day Follow-Up Visit. Adverse events, concomitant medications, and procedural tolerability will be monitored throughout the study period. This study is designed to support the intended use of the CLiKX device for performing myringotomy and facilitating delivery of tympanostomy tubes through the tympanic membrane in a clinical setting.

Interventions

DEVICECLiKX® Tympanostomy Tube Delivery System

The CLiKX device is an automated, sensor-optimized, partially reusable handheld surgical device used for tympanostomy tube placement. It consists of multiple components assembled before use and disassembled after the procedure. The device includes integrated, pre-programmed software that controls its mechanical actions. The software is locked, cannot be modified by users, and does not perform diagnostic or therapeutic decision-making. Instead, it provides visual cues and applies controlled force to assist the procedure. Compared to manual techniques, the CLiKX device automates key steps, including creating a precise slit incision using regulated force. This approach is designed to reduce operator variability, minimize trauma to the tympanic membrane, and improve accuracy of tube placement. Clinicians retain full control over targeting throughout the procedure.

Sponsors

ClinQure, Inc.
Lead SponsorNETWORK
NousQ Pte Ltd
CollaboratorUNKNOWN

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
6 Months to No maximum
Healthy volunteers
No

Inclusion criteria

1. Subject is scheduled to undergo tympanostomy tube insertion. 2. Subject is ≥ 6 months old at the time of informed consent. 3. Subject has an ear canal diameter of ≥ 4 mm. 4. Subject is able and willing to provide informed consent or subject's parent/guardian is able and willing to provide informed consent and subject is able and willing to provide assent as age appropriate (age 7 years to 21 years old).

Exclusion criteria

1. Subjects who are pregnant as confirmed by the institution's standard pre- surgery practice. 2. Subjects with known adverse reaction to anesthesia. 3. Subjects with atrophic, dimeric, severely thinned and scarred, severely thickened, severely retracted, atelectatic or perforated tympanic membrane. 4. Subjects with otitis externa. 5. Subjects with active acute otitis media. 6. Subjects with an ear canal diameter \< 4 mm. 7. Ear drums that are overly vertical or horizontal 8. Subjects with an anatomy that precludes visualization and access to the tympanic membrane, in the opinion of the investigator. 9. Subjects with any condition that, in the opinion of the investigator, may place the subject at greater risk. 10. Subjects with suspected middle ear tumors or vascular lesions. 11. Subjects diagnosed with acute sensorial hearing loss 12. Subjects with a history of surgery involving the ear drum. 13. Subjects with hemotympanum. 14. Subject is not able or willing to comply with study procedures and follow-up requirements, in the opinion of the investigator.

Design outcomes

Primary

MeasureTime frameDescription
Effectiveness of C-TTDS for tympanostomy tube placementAt time of procedure (first or second attempt)Effectiveness will be determined by success at the end of each ear tube procedure. Effectiveness is defined as the successful incision in the tympanic membrane and delivery of tympanostomy tube across the tympanic membrane in the proper position after a maximum of 2 insertion attempts per indicated ear. An insertion attempt is defined as an incision in the tympanic membrane by the C-TTDS
Safety of C-TTDS for tympanostomy tube placementAt time of procedure (first or second attempt)Safety will be assessed by incidence, severity and relatedness of device related adverse events occurring during the overall procedure.

Secondary

MeasureTime frameDescription
FLACC Pain Scale≤ 1.0 hour after completion of the tympanostomy procedure at the Post-Tympanostomy Procedure VisitFace, Legs, Activity, Cry, and Consolability observational pain rating scalle for Infants and children less greater than or equal to 6 months to 5 years of age.
FPS-R≤ 1.0 hour after completion of the tympanostomy procedure at the Post-Tympanostomy Procedure VisitFaces Pain Rating Scale - Revised self-reporting pain rating scale for children greater than or equal to 5 to 7 years of age
NRS Pain Scale≤ 1.0 hour after completion of the tympanostomy procedure at the Post-Tympanostomy Procedure Visit11-point Number Rating Scale for Pain. Provided to children, adolescents, and adults greater than or equal to 7 years of age
Caregiver Satisfaction Survey≤ 1.0 hour after completion of the tympanostomy procedureProcedure satisfaction and acceptability will be assessed using a subject-, parent-, guardian-, and/or caregiver-reported satisfaction survey evaluating procedure tolerability, satisfaction, perceived importance of alternatives to general anesthesia, perceived reduction in cost and procedure time, and willingness to recommend the procedure to others. Survey responses will be assessed using a 5-point Likert scale: 1. = Strongly Disagree 2. = Disagree 3. = Neutral 4. = Agree 5. = Strongly Agree Higher scores indicate greater procedure satisfaction and acceptability.
Physician Procedure Tolerability Evaluation≤ 1.0 hour after completion of the tympanostomy procedurePerforming surgeon and anesthesiologist acceptability of subject tolerability of the procedure. Binary 'Yes' or 'No' response

Countries

United States

Contacts

CONTACTCrystal George
crystal@clinqure.com972-999-2070

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Sep 12, 2026