Hearing Outcomes With the Nucleus® 8 Sound Processor and Nucleus® 7 Sound Processor in Adult Veteran and Non-veteran Cochlear Implant Recipients

A Post-market Interventional, Prospective, Open-label, Multi-center, Clinical Investigation of Hearing Outcomes With the Nucleus 8 Sound Processor and Nucleus 7 Sound Processor in Adult Veteran and Non-veteran Cochlear Implant Recipients

Status
Not yet recruiting
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT07582198
Acronym
SALUTE
Enrollment
26
Registered
2026-05-12
Start date
2026-05-01
Completion date
2026-09-01
Last updated
2026-05-12

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Hearing Loss

Brief summary

The main purpose of this study is to understand how well a noise reduction feature called ForwardFocus works when used with two different sound processors: the Nucleus® 8 Sound Processor and the Nucleus® 7 Sound Processor, in adults with cochlear implants. The study will include two groups of adult cochlear implant recipients: veterans and non-veterans. Comparing these groups will help researchers understand how these sound processors perform in veteran populations as well as the broader adult cochlear implant community. Participants will use each sound processor and then take part in speech understanding tests in background noise. They will also complete questionnaires about their listening experiences with each processor.

Interventions

DEVICENucleus 7 Sound Processor

While the user can turn ForwardFocus on from any program in the Nucleus 7 Sound Processor, for the duration of this study, SCAN will be used as the default program and ForwardFocus will be turned on for testing. This setting will be referred to as SCAN ForwardFocus (SCAN FF).

DEVICENucleus 8 Sound Processor

Nucleus 8 Sound Processor will be used with the SCAN 2 ForwardFocus (SCAN 2 FF) program to evaluate speech performance.

Sponsors

Cochlear
Lead SponsorINDUSTRY

Study design

Allocation
RANDOMIZED
Intervention model
CROSSOVER
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1. Aged 18 years or older, at time of consent. 2. Implanted with the CI600 Series (CI612, CI632, CI622, CI624), CI500 Series (CI512, CI532, CI522) or Freedom Series (CI24R(CA), CI24R(ST) CI24R(CS), CI24M, CI24RE(CA), CI24RE(ST), CI422) in the test ear. 3. At least 18 active electrodes in the test ear. 4. At least 6 months experience with a cochlear implant in the test ear. 5. Able to score 20% or more at +10 dB SNR with CI alone on an S0N0 sentence in-noise test in the test ear. 6. Pure-tone average unaided threshold (500 through 4000 Hz) ≥ 30 dB HL, in the contralateral ear. 7. Candidate is a fluent speaker in the language used to assess speech perception performance. 8. Direct access to a compatible smartphone. 9. Willing and able to provide written informed consent.

Exclusion criteria

1. Recipients with single-sided deafness as determined by the Investigator. 2. Additional disabilities that would prevent participation in evaluations. 3. Unrealistic expectations on the part of the subject, regarding the possible benefits, risks and limitations that are inherent to the procedures. 4. Unable or unwilling to comply with the requirements of the clinical investigation as determined by the Investigator. 5. Investigator site personnel directly affiliated with this study and/or their immediate families; immediate family is defined as a spouse, parent, child, or sibling. 6. Cochlear employees or employees of Contract Research Organizations or contractors engaged by Cochlear for the purposes of this investigation. 7. Current participation, or participation in another interventional clinical study/trial in the past 30 days, involving an investigational drug or device (unless Cochlear sponsored and determined by Investigator or Sponsor to not impact this investigation).

Design outcomes

Primary

MeasureTime frameDescription
Paired difference in AzBio percent correct in noise between the Nucleus 8 Sound Processor using the SCAN 2 FF program and the Nucleus 7 Sound Processor using the SCAN FF program at a fixed signal-to-noise ratio in the S0N90 spatial configurationWeek 2 and week 4The AzBio sentence test is a validated test used to assess open-set sentence recognition. AzBio sentences are spoken in a conversational style with limited contextual cues that the listener can use to predict unintelligible words.

Secondary

MeasureTime frameDescription
Paired difference in AzBio percent correct in noise between the Nucleus 8 Sound Processor using the SCAN 2 FF program and the Nucleus 7 Sound Processor using the SCAN FF program at a fixed signal-to-noise ratio in the S90N180 spatial configurationWeek 2 and week 4The AzBio sentence test is a validated test used to assess open-set sentence recognition. AzBio sentences are spoken in a conversational style with limited contextual cues that the listener can use to predict unintelligible words.
Paired difference in AzBio percent correct in noise between the Nucleus 8 Sound Processor using the SCAN 2 FF program and the Nucleus 7 Sound Processor using the SCAN FF program at a fixed signal-to-noise ratio in the S0N180 spatial configurationWeek 2 and week 4The AzBio sentence test is a validated test used to assess open-set sentence recognition. AzBio sentences are spoken in a conversational style with limited contextual cues that the listener can use to predict unintelligible words.
Paired difference in AzBio improvement (percentage-point change) for the Nucleus 8 Sound Processor (SCAN 2 FF minus SCAN 2) compared to the Nucleus 7 Sound Processor (SCAN FF minus SCAN) in the S0N180 spatial configurationWeek 2 and week 4The AzBio sentence test is a validated test used to assess open-set sentence recognition. AzBio sentences are spoken in a conversational style with limited contextual cues that the listener can use to predict unintelligible words.
Paired difference in CNC percent correct in quiet between the Nucleus 8 Sound Processor using the SCAN 2 FF program and the Nucleus 7 Sound Processor using the SCAN FF program in the S0 spatial configurationWeek 2 and week 4The consonant-nucleus-consonant (CNC) monosyllabic word test will be used to assess speech perception of words in quiet. The test consists of 10 recorded lists of 50 monosyllabic words, produced by a male talker.
Paired difference in AzBio percent correct in quiet between the Nucleus 8 Sound Processor using the SCAN 2 FF program and the Nucleus 7 Sound Processor using the SCAN FF program in the S0 spatial configurationWeek 2 and week 4The AzBio sentence test is a validated test used to assess open-set sentence recognition. AzBio sentences are spoken in a conversational style with limited contextual cues that the listener can use to predict unintelligible words.
Paired difference in AzBio percent correct in noise between the Nucleus 8 Sound Processor using the SCAN 2 FF program and the Nucleus 7 Sound Processor using the SCAN FF program at a fixed signal-to-noise ratio in the S0N0 spatial configurationWeek 2 and week 4The AzBio sentence test is a validated test used to assess open-set sentence recognition. AzBio sentences are spoken in a conversational style with limited contextual cues that the listener can use to predict unintelligible words.
Proportion of participants preferring each sound processor in various listening domainsWeek 4The Device Preference Questionnaire is a custom self-assessment to evaluate participants' preference between the Nucleus 8 and Nucleus 7 Sound Processors, or "no preference".
Mean difference in SSQ-12 total scores between the Nucleus 8 Sound Processor and the Nucleus 7 Sound ProcessorWeek 2 and Week 4The SSQ-12 is a validated 12-item abbreviated form of the Speech, Spatial, and Qualities of Hearing scale that measures self-reported hearing ability across speech, spatial, and sound quality domains, with each item rated from 0 (poor) to 10 (excellent). Total scores are calculated by averaging responses across relevant items.
Mean difference in VFS-A-10 total scores between the Nucleus 8 Sound Processor and the Nucleus 7 Sound ProcessorWeek 2 and Week 4The Vanderbilt Fatigue Scale-10-Item Adult (VFS-A-10) is a validated 10-item subjective scale designed to assess listening-related fatigue in adults with hearing loss. The scale provides a total score based on all 10 questions rated on a Likert scale from 0 (no listening-related fatigue) to 4 (severe listening-related fatigue).