Digital vs Conventional Stabilizing Splints in Temporomandibular Disorders

A Randomized Controlled Trial Comparing Digitally Fabricated and Conventional Stabilizing Splints in the Management of Temporomandibular Disorders

Status
Enrolling by invitation
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT07566936
Enrollment
120
Registered
2026-05-05
Start date
2026-01-01
Completion date
2026-10-26
Last updated
2026-05-05

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Temporomandibular Disorders (TMD)

Keywords

Occlusal splints, stabilizing splints, Three dimensional Printing, Temporomandibular joint Disorder, Temporomandibular Disorders (TMD)

Brief summary

This randomized controlled trial aims to compare the clinical effectiveness of digitally fabricated and conventionally fabricated maxillary stabilization splints in patients diagnosed with Temporomandibular Disorders (TMD) according to Diagnostic Criteria for Temporomandibular Disorders (DC/TMD). Participants will be randomly allocated in a 1:1 ratio to receive either a Digitally fabricated splint produced using computer-aided design and three-dimensional printing technology or a conventionally fabricated splint using standard impression and laboratory techniques. The primary outcome is Change in Pain Intensity measured using the Characteristic Pain Intensity component of the Graded Chronic Pain Scale (GCPS), 0-100 scale. Higher scores indicate greater pain severity from baseline to 3 months as primary end point. Secondary outcomes include change in pain-related disability assessed using the Graded Chronic Pain Scale (GCPS) disability score, change in maximum mouth opening measured in millimeters (mm), change in jaw functional limitation assessed using the Jaw Functional Limitation Scale (JFLS), resolution of temporomandibular joint (TMJ) clicking (present/absent), change in oral health-related quality of life assessed using the Oral Health Impact Profile-14 (OHIP-14), and compliance with splint use measured as average nightly wear time (hours per night). Assessments will be conducted at baseline and 3 months post-intervention. Outcome assessment will be performed by a blinded examiner.

Detailed description

This study is a parallel-group randomized controlled clinical trial designed to evaluate the effect of fabrication technique on the clinical performance of stabilization splints in patients with temporomandibular disorders (TMD). Eligible participants will be diagnosed according to Diagnostic Criteria for Temporomandibular Disorders (DC/TMD) Axis I criteria. Following informed consent, participants will be randomly assigned in a 1:1 ratio to either the digitally fabricated splint group or the conventionally fabricated splint group using a computer-generated randomization sequence. Allocation concealment will be ensured by sequentially generated numbered, opaque, sealed envelopes prepared by an independent investigator. For the digital workflow, maxillary and mandibular arches will be captured using an intra oral scanner. Splints will be designed using computer-aided design software and fabricated using additive manufacturing (three-dimensional printing) with biocompatible resin materials via digital light processing (DLP) technology. Post-processing will include cleaning and light curing according to standardized protocols. For the conventional workflow, impressions will be obtained using elastomeric materials, followed by cast fabrication and articulation. Stabilization splints will be fabricated using heat-cured acrylic resin according to standardized laboratory procedures. To ensure comparability between groups, splint design parameters will be standardized. All appliances will be maxillary full-coverage stabilization splints with even and simultaneous bilateral contacts in centric relation and canine-guided occlusion during excursive movements. Splint thickness will be standardized (approximately 2-3 mm), and all appliances will be adjusted intraorally at delivery to achieve uniform occlusal contacts. Participants will be instructed to wear the splints nightly for a minimum of 8 hours. Clinical evaluations will be conducted at baseline and 3 months post-intervention. Outcome assessment will be performed by an examiner blinded to group allocation. Data will be analyzed using IBM SPSS Statistics (version 26.0; IBM Corp., Armonk, NY, USA). A two-sided p-value \< 0.05 will be considered statistically significant.. Normality will be assessed using the Shapiro-Wilk test. Between-group comparisons will be performed using independent t-tests or Mann-Whitney U tests, as appropriate. Within-group comparisons will be conducted using paired t-tests or Wilcoxon signed-rank tests. Repeated measures will be analyzed using repeated measures ANOVA or mixed-effects models. This study is designed to isolate the effect of fabrication technique by controlling splint design variables while employing clinically relevant material systems, thereby providing evidence on the comparative effectiveness of digitally fabricated and conventionally fabricated stabilization splints in the management of temporomandibular disorders.

Interventions

A conventional stabilizing splint is a removable dental appliance that fits over the upper or lower teeth. It is made using traditional laboratory methods from heat cure acrylic material based on a standard impression of the patient's teeth.

A digital stabilizing splint is a removable appliance that fits over the teeth and is made using digital scanning and three dimensional printing technology. A digital scan of the patient's teeth is used to design the splint on a computer, and it is then fabricated using three dimensional printing technology using a biocompatible material.

Sponsors

Shifa Tameer-e-Millat University
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
SINGLE (Outcomes Assessor)

Intervention model description

Participants will be randomized in a 1:1 ratio to one of two parallel groups receiving either digitally fabricated or conventionally fabricated maxillary stabilization splints. Both groups will be managed under standardized clinical protocols, with identical follow-up schedules and outcome assessment procedures. Clinical evaluations will be conducted at baseline, and 3 months post-intervention. Allocation will remain fixed throughout the study period, with no crossover between interventions. Outcome assessment will be performed by a blinded examiner.

Eligibility

Sex/Gender
ALL
Age
18 Years to 40 Years
Healthy volunteers
No

Inclusion criteria

* Adults aged 18-40 years * Diagnosis of Temporomandibular Disorder (TMD) according to standardized Diagnostic Criteria for Temporomandibular disorders Axis I * Maximum unassisted mouth opening between 20-30 mm * Symptoms present for ≥3 months (to exclude transient/self-limiting cases) * Willingness to comply with study protocol and provide informed consent

Exclusion criteria

* Diagnosis of temporomandibular joint myalgia or Myofascial pain as the primary condition * History of trauma to the temporomandibular joint or mandible * Presence of degenerative joint diseases (e.g., osteoarthritis, rheumatoid arthritis) * Congenital or developmental craniofacial anomalies affecting temporomandibular joint * Prior temporomandibular joint surgery or ongoing orthodontic treatment * Current use of: Analgesics, muscle relaxants, or anti-inflammatory drugs affecting temporomandibular joint symptoms * Prior Occlusal splint therapy within the last 3 months * Systemic conditions affecting joint function (e.g., connective tissue disorders) * Pregnancy or lactation (if intervention may influence compliance or physiology

Design outcomes

Primary

MeasureTime frameDescription
Change in Pain IntensityBaseline to 3 months post-interventionChange in Pain intensity will be assessed using the Characteristic Pain Intensity (CPI) component of the Graded Chronic Pain Scale (GCPS). The CPI is calculated based on patient-reported current, worst, and average pain scores and is expressed on a 0-100 scale, where higher scores indicate greater pain intensity. The outcome measure is the mean change in CPI score from baseline to 3 months post-intervention.

Secondary

MeasureTime frameDescription
Change in Pain-Related DisabilityBaseline to 3 months post-interventionChange in Pain-related disability will be assessed using the disability component of the Graded Chronic Pain Scale (GCPS), which includes three items evaluating interference with daily activities, social activities, and work, each scored on a 0-10 scale. The mean of these items is multiplied by 10 to generate a disability score ranging from 0 to 100, where higher scores indicate greater disability. The outcome measure is the mean change in disability score from baseline to 3 months post-intervention.
Change in maximum mouth opening (MMO)Baseline to 3 months post-interventionMaximum mouth opening will be measured as the maximum unassisted inter-incisal distance (in millimeters) using a calibrated ruler or digital caliper. Measurements will be obtained under standardized conditions at each assessment visit. The outcome measure is the mean change in MMO (mm) from baseline to 3 months post-intervention, where higher values indicate improved mandibular function.
Change in Jaw Functional LimitationBaseline to 3 months post-interventionFunctional limitation will be assessed using the Jaw Functional Limitation Scale (JFLS-20), a validated patient-reported outcome measure consisting of 20 items evaluating mastication, vertical jaw mobility, and emotional and verbal expression. Each item is scored on a 0-10 scale, and the total score is calculated as the mean of all items, resulting in a score ranging from 0 to 10, where higher scores indicate greater functional limitation. The outcome measure is the mean change in JFLS-20 score from baseline to 3 months post-intervention.
Resolution of Temporomandibular joint (TMJ) clickingBaseline and 3 months post interventionResolution of TMJ clicking will be assessed clinically during mandibular opening and closing movements by a trained examiner under standardized conditions. Clicking will be recorded as a dichotomous variable (present/absent) based on the presence of an audible or palpable click during at least one of three consecutive mandibular opening-closing cycles. The outcome measure is the proportion of participants demonstrating resolution of TMJ clicking (present at baseline and absent at 3 months post-intervention).
Change in oral health-related quality of lifeBaseline to 3 months post-interventionOral health-related quality of life will be assessed using the Oral Health Impact Profile-14 (OHIP-14), a validated questionnaire consisting of 14 items evaluating functional limitation, physical pain, psychological discomfort, physical disability, psychological disability, social disability, and handicap. Each item is scored on a 5-point Likert scale (0 = never to 4 = very often), with total scores ranging from 0 to 56, where higher scores indicate worse oral health-related quality of life. The outcome measure is the mean change in OHIP-14 total score from baseline to 3 months post-intervention.
Compliance with splint useFrom intervention (day of splint delivery) to 3 months post-intervention, with compliance recorded continuously and summarized as average nightly wear time at 3 months.Compliance with splint use will be assessed based on patient-reported average nightly wear time (hours per night), recorded using a standardized daily log. Participants will document the number of hours the splint is worn each night throughout the study period. The outcome measure is the mean average nightly wear time (hours/night) over the 3-month follow-up period.

Countries

Pakistan

Contacts

STUDY_DIRECTORProf Anwar Ali Shah, BDS, PhD, M-Orth, FDSRCS

Shifa Tameer-e-Millat University

Outcome results

None listed