Skip to content

Medeliver Intracranial Drug Coated Balloon Catheter for Symptomatic Intracranial Atherosclerotic Stenosis

Safety and Efficacy of Medeliver Intracranial Drug Coated Balloon Catheter for Symptomatic Intracranial Atherosclerotic Stenosis(Prospective, Multicenter, Randomized Controlled, Superiority Trial)

Status
Recruiting
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT07542938
Enrollment
264
Registered
2026-04-21
Start date
2026-04-15
Completion date
2027-11-30
Last updated
2026-09-10

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Symptomatic Intracranial Atherosclerotic Stenosis

Brief summary

To evaluate the safety and efficacy of the Medeliver® Intracranial Drug-Coated Balloon Catheter (developed by Beijing Jiu Shi Shen Kang Medical Technology Co., Ltd.) in the endovascular treatment of symptomatic intracranial atherosclerotic stenosis.

Interventions

DEVICEIntracranial Drug-Coated Balloon Catheter (Medeliver®)

The Medeliver® intracranial drug-coated balloon dilatation catheter is indicated for interventional treatment of symptomatic intracranial atherosclerotic stenosis lesions. It restores the original vascular lumen through balloon dilatation of the stenotic segment while simultaneously delivering an anti-proliferative agent (sirolimus/rapamycin) coated on the balloon surface to the lesion site.

DEVICEIntracranial Balloon Dilatation Catheter (Diveroad®)

The Diveroad® intracranial balloon dilatation catheter is indicated for interventional treatment of symptomatic intracranial atherosclerotic stenosis lesions. It restores the original vascular lumen through balloon dilatation of the stenotic segment.

Sponsors

Xuanwu Hospital, Beijing
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
SINGLE (Outcomes Assessor)

Eligibility

Sex/Gender
ALL
Age
18 Years to 80 Years
Healthy volunteers
No

Inclusion criteria

1. Age 18-80 years; 2. Symptomatic intracranial arterial stenosis within the past 6 months, with 70%-99% diameter stenosis on angiography (per WASID criteria); 3. Target lesion located in: intracranial segment of the internal carotid artery (C3 or above), M1/M2 segment of the middle cerebral artery, basilar artery, or intracranial segment of the vertebral artery; 4. At least one atherosclerotic risk factor (history or current hypertension, diabetes mellitus, hyperlipidemia, hyperhomocysteinemia, smoking, or alcohol consumption); 5. Reference vessel diameter adjacent to the target lesion ≥ 2 mm; 6. Baseline mRS score ≤ 2; 7. Patient or legally authorized representative understands the study purpose, voluntarily agrees to participate, provides written informed consent, and is willing and able to comply with follow-up visits.

Exclusion criteria

1. Acute ischemic stroke within 2 weeks prior to screening; 2. Major surgery or acute myocardial infarction within 30 days prior to screening; 3. Intracranial hemorrhage (parenchymal, subarachnoid, subdural, or extradural) within 3 months prior to screening; 4. Uncontrolled hypertension despite medical therapy (systolic BP ≥ 180 mmHg or diastolic BP ≥ 110 mmHg); 5. Coexisting intracranial tumor, intracranial aneurysm requiring treatment, or arteriovenous malformation; 6. Previous stenting of the target lesion or any intracranial stenting/endovascular procedure within the past 3 months; 7. Cardioembolic stroke; 8. Stroke caused solely by perforator artery occlusion; 9. Two or more consecutive lesions with ≥ 70% stenosis in the target vessel; 10. Additional de novo or in-stent restenosis lesions (\> 70% diameter stenosis);in other intracranial arteries requiring treatment during the same session; 11. Severe calcification, extreme angulation, severe tortuosity, or other anatomical features in the target vessel that may prevent safe device delivery or retrieval; 12. Known allergy or contraindication to heparin, sirolimus (rapamycin), iodinated contrast, aspirin, clopidogrel, or local anesthetics; 13. Gastrointestinal bleeding within 6 months prior to informed consent, rendering antiplatelet therapy unsafe; 14. Platelet count \< 90 × 10⁹/L; 15. INR \> 1.5; 16. Pregnant, breastfeeding, or planning pregnancy within 1 year; 17. Life expectancy \< 1 year; 18. Participation in another drug or device clinical trial currently or planned during the study period; 19. Intracranial stenosis due to non-atherosclerotic etiology (e.g., arterial dissection, moyamoya disease, vasculitis, active arteritis, thrombosis); 20. Severe or unstable comorbidities (e.g., severe heart failure, respiratory failure, renal failure \[serum creatinine \> 3.0 mg/dL or 264 µmol/L\], severe hepatic impairment \[ALT/AST \> 3 × ULN\], active malignancy); 21. Flow-limiting dissection or residual stenosis \> 50% after pre-dilatation; 22. Any other condition that, in the investigator's judgment, makes the patient unsuitable for enrollment;

Design outcomes

Primary

MeasureTime frame
The 12-month post-procedural rates of target lesion restenosis, stroke recurrence or mortality in the territory of the target vessel.From enrollment to the end of follow-up at 12 months

Countries

China

Contacts

CONTACTZhen Li Beijing Highland Med-Tech Development Co.,Ltd
jason.lee@hld-cro.com18611537116

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Sep 11, 2026