Skip to content

Radiographic and Retention Evaluation Over Seven Years for Four Implant Retained Overdenture

Marginal Bone Loss and Retention of Four-Implant Locator-Retained Mandibular Overdentures: 7 Years Follow up

Status
Completed
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT07536776
Enrollment
27
Registered
2026-04-17
Start date
2018-01-12
Completion date
2026-02-20
Last updated
2026-08-13

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Marginal Bone Loss Around Implants

Brief summary

ABSTRACT Statement of the problem: Insufficient long-term retrospective data is evaluating marginal bone loss and retention of four-implant Locator-retained mandibular overdentures. Purpose: To assess marginal bone loss and retention of four-implant Locator-retained mandibular overdentures over seven years at the time of overdenture insertion (T0), 1 year (T1), and 7 years (T7) after insertion. Material and methods: This retrospective study included 27 completely edentulous patients with maxillary single denture, and four parallel implants were placed interforaminal, and they already have a mandibular four-implant retained overdenture with LOCATOR attachments.

Interventions

OTHERimplant retained overdenture

4 implants retained prosthesis by locators

DEVICEfour dental implant with locator attachment

A mandibular overdenture retained by four dental implants using Locator attachments. The implants are positioned in the anterior and premolar regions of the mandible, and the prosthesis is retained by four Locator attachments. Patients are followed clinically and radiographically over the follow-up period.

Sponsors

Mansoura University
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Healthy volunteers
No

Inclusion criteria

Patients rehabilitated with a mandibular overdenture retained by four dental implants. Four implants positioned in the anterior and premolar regions of the mandible. Four Locator attachments used to retain the mandibular overdenture. Availability of baseline clinical and radiographic records at the time of prosthesis insertion. Availability of clinical and radiographic records at 1-year and 7-year follow-up.

Exclusion criteria

Patients with incomplete clinical or radiographic records. Patients without the required 1-year or 7-year follow-up records. Patients with radiographs that were inadequate for reliable assessment of peri-implant marginal bone levels. Patients whose records did not allow assessment of prosthetic retention at the specified follow-up periods.

Design outcomes

Primary

MeasureTime frameDescription
Marginal Bone Loss by periapical radiographyFrom the time of implant loading (Baseline), 1year and 7 years.Marginal bone loss will be assessed using standardized intraoral periapical radiographs. The vertical distance from the implant reference point to the alveolar bone crest will be measured on the mesial and distal surfaces of each implant. Measurements will be recorded at implant insertion (baseline), 1 year, and 7 years, and the mean value of the four implants will be calculated for each patient.

Secondary

MeasureTime frameDescription
Prosthetic Retention by a digital force gaugebaseline, 1year and 7 years.Prosthetic retention will be assessed by measuring the dislodging force required to remove the mandibular overdenture using a digital force gauge. The retention force will be recorded in Newtons (N) at baseline and at 7 years after insertion.

Countries

Egypt

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Aug 14, 2026