Skip to content

Comparative Study of Denture Fabrication Techniques

Comparative Study of Traditional Complete Denture Fabrication Technique and the Easdent Digital Complete Denture Fabrication Technique in a Predoctoral Dental Clinic

Status
Not yet recruiting
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT07525011
Enrollment
20
Registered
2026-04-13
Start date
2026-04-30
Completion date
2028-05-30
Last updated
2026-04-13

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Complete Edentulism

Keywords

Complete Denture, Conventional Complete Denture, Digital Complete Denture, Edentulous Patients, Dental Education, Denture Workflow, Removable Prosthodontics

Brief summary

This study is a randomized, single-blinded clinical study conducted in the predoctoral clinic at Rutgers School of Dental Medicine. The purpose of this study is to compare a traditional complete denture fabrication technique with the Easdent digital complete denture workflow. The Easdent technique is a modification of the conventional method and utilizes FDA-approved materials and 3D-printed trays designed to record teeth position, jaw relations and impression information. Participants who require new dual-arch complete dentures will receive dentures fabricated using both techniques. The order of fabrication and delivery will be randomized. Clinical chair time, number of appointments, and total treatment time will be recorded. Patient-reported outcomes will be assessed using a modified OHIP-EDENT survey and preference questions after completion of both dentures. Student participants will also complete surveys evaluating learning experience and clinical usability. The study does not evaluate the safety or effectiveness of a drug or investigational device. All materials used are FDA-cleared and routinely used in clinical practice. The overall aim is to evaluate efficiency, patient satisfaction, and educational usability of the two denture fabrication workflows.

Detailed description

Complete dentures remain a common treatment for fully edentulous patients. The traditional complete denture fabrication workflow requires multiple clinical visits, including preliminary impressions, custom tray fabrication, border molding, final impressions, record base and wax rim fabrication, jaw relation records, tooth try-in, and final delivery. This process is technique-sensitive, time-intensive, and may require numerous patient appointments. In predoctoral dental education settings, the complexity of the workflow can also contribute to variability in clinical efficiency and student learning experience. The Easdent digital complete denture workflow is a modification of the conventional technique. It incorporates 3D-printed trays fabricated from FDA-cleared medical-grade denture tray or try-in denture materials. These trays are designed with features similar to try-in dentures, including standardized tooth positioning and idealized intercuspation between maxillary and mandibular arches. Retention holes are incorporated to allow the use of conventional impression materials in a manner similar to traditional stock trays. The trays are produced in multiple standardized sizes to accommodate variation in jaw dimensions. The workflow is intended to streamline the recording of esthetics (such as midline and horizontal reference lines), occlusal vertical dimension, and maxillomandibular relationships while maintaining compatibility with conventional denture processing techniques. This study is designed to compare the traditional complete denture workflow with the Easdent digital complete denture workflow in a predoctoral clinical environment. The investigation focuses on efficiency, patient-reported outcomes, and educational usability rather than safety or effectiveness of a drug or investigational device. All materials used in this study are FDA-cleared and routinely used in standard dental practice. Participants who require new dual-arch complete dentures will receive dentures fabricated using both workflows. The order of fabrication and delivery will be randomized to reduce sequencing bias. The study uses a single-blinded design in which participants are not informed which denture corresponds to which fabrication method at the time of evaluation. After completion and adjustment of both dentures, participants will complete standardized patient-reported surveys and indicate their preference. Clinical efficiency metrics include the number of appointments required, chair time per visit, and total treatment duration associated with each workflow. These data are recorded prospectively by trained student researchers under faculty supervision. Standardization procedures, including calibration sessions and training lectures, are implemented to reduce inter-operator variability. Patient-reported outcomes are assessed using a modified OHIP-EDENT 19 questionnaire, supplemented with additional items evaluating esthetic satisfaction and overall satisfaction. Surveys are administered after an adaptation period following delivery of both dentures to allow patients to assess comfort, function, and esthetics. Preference data are collected after participants have experienced both prostheses. In addition to patient outcomes, the study evaluates the educational impact of the two workflows. Student researchers complete structured surveys assessing perceived learning difficulty, procedural complexity, and overall workflow usability. This component is intended to evaluate feasibility and integration of the modified workflow within a predoctoral dental curriculum. The anticipated risks are consistent with routine complete denture treatment and include temporary mucosal soreness, minor discomfort during impression procedures, temporary speech adaptation, and the potential need for post-insertion adjustments. No additional risks beyond standard denture treatment are introduced by study participation. The study is considered minimal risk. The findings of this study may provide data regarding clinical efficiency, patient-centered outcomes, and educational feasibility of a modified denture fabrication workflow in an academic clinical setting. Results may inform decisions regarding curriculum design and clinical workflow optimization in complete denture therapy.

Interventions

PROCEDURETraditional Complete Denture Fabrication

Conventional complete denture fabrication performed using standard clinical procedures, including preliminary impressions, custom tray fabrication, border molding, final impressions, record base and wax rim fabrication for recording occlusal vertical dimension and maxillomandibular relationship, tooth try-in appointment, denture processing, delivery, and post-insertion adjustments. All materials used are FDA-cleared and routinely utilized in standard dental practice.

PROCEDUREEasdent Digital Complete Denture Fabrication

Complete denture fabrication performed using the Easdent digital complete denture workflow. This technique incorporates 3D-printed trays fabricated from FDA-cleared medical-grade denture tray or try-in denture materials. The trays are designed with standardized tooth positioning and retention features to facilitate recording of esthetics, occlusal vertical dimension, and maxillomandibular relationships using conventional impression materials. Subsequent clinical and laboratory procedures follow standard denture processing methods, including denture fabrication, delivery, and post-insertion adjustments.

Sponsors

Rutgers, The State University of New Jersey
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
CROSSOVER
Primary purpose
OTHER
Masking
SINGLE (Subject)

Masking description

Participants will not be informed which denture corresponds to the traditional fabrication workflow or the Easdent digital workflow at the time of evaluation. Student providers, supervising faculty, and investigators will be aware of the fabrication method used. No other parties are masked.

Intervention model description

This study uses a randomized crossover design. Each enrolled participant will receive two sets of complete dentures fabricated using two different workflows: the conventional complete denture technique and the Easdent digital complete denture workflow. The order in which the dentures are fabricated and delivered will be randomized to minimize sequence effects. After both dentures are completed and delivered, participants will evaluate each prosthesis following an adaptation period. Outcomes related to clinical efficiency and participant-reported measures will be collected for both workflows within the same individual, allowing each participant to serve as their own control.

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Adults aged 18 years or older. * Requiring new dual-arch complete dentures. * Willing and able to attend for all required study appointments, including delivery and follow-up visits.

Exclusion criteria

* Requiring only single-arch complete dentures. * Presence of severe medical conditions that would preclude attendance at multiple prosthodontic appointments. * Active, untreated oral mucosal disease that would prevent impression making or denture fabrication. * Severely resorbed edentulous ridges. * Unable or unwilling to attend for all scheduled study visits or follow-up appointments. * Unable to comply with instructions necessary for denture treatment or study procedures.

Design outcomes

Primary

MeasureTime frameDescription
Total Clinical Chair Time per Denture Fabrication MethodFrom initial impression appointment to final denture delivery (approximately 1-4 months)Total accumulated clinical chair time (in minutes) required to complete denture fabrication for each workflow, measured from initial impression appointment through final delivery and necessary adjustments.

Secondary

MeasureTime frameDescription
Patient-Reported Oral Health-Related Quality of Life (Modified Oral Health Impact Profile for Edentulous Adults Score)From enrollment to the end of treatment, an average of 4 monthsPatient-reported outcomes will be measured using a modified version of the Oral Health Impact Profile for Edentulous Adults 19 questionnaire. This modified instrument consists of 22 items: the original 19 OHIP-EDENT questions plus 3 additional items assessing esthetic and overall satisfaction. Each item is rated on a 5-point Likert scale, where 1 represents the minimum (poorest) score and 5 represents the maximum (best) score. Total scores are calculated by summing the responses to all 22 items, resulting in a possible score range from 22 (minimum) to 110 (maximum). A higher score indicates a better outcome (higher quality of life). Domain-specific subscores will also be calculated and reported.

Countries

United States

Contacts

CONTACTHeba Elkassaby, DMD, MDSc, FACP
hte9@sdm.rutgers.edu973-972-6997
CONTACTHua Zhu, DMD, PhD, MD
zhuhu1@sdm.rutgers.edu973-972-4615
PRINCIPAL_INVESTIGATORHeba Elkassaby, DMD, MDSc, FACP

Rutgers, The State University of New Jersey

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Apr 14, 2026