Skip to content

Robotic Transjugular Transcatheter Tricuspid Valve Replacement

Robotic Transjugular Transcatheter Tricuspid Valve Replacement

Status
Recruiting
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT07516145
Acronym
Robotic Lux
Enrollment
10
Registered
2026-04-07
Start date
2026-03-12
Completion date
2028-03-31
Last updated
2026-04-07

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Transcatheter Valve Replacement, Tricuspid Regurgitation (TR), Valvular Heart Diseases

Keywords

Tricuspid Regurgitation, Valvular heart diseases, Transcatheter Valve Replacement

Brief summary

Valvular heart disease (VHD), caused by abnormalities in heart valves, can lead to severe complications such as heart failure and death, with approximately 220 million affected patients worldwide. The prevalence of VHD continues to grow alongside the aging global population. Transcatheter heart valve interventions have emerged as minimally invasive alternatives, offering benefits like shorter recovery times and reduced discomfort. However, current manual catheter-based techniques are complex, highly dependent on clinicians' expertise, and involve significant physical risk due to prolonged exposure to X-ray radiation and cumbersome protective gear. To address these challenges, a novel, universal intracardiac robotic system is proposed to improve precision, safety, and procedural efficiency. This system integrates a high-dexterity, load-capacity catheter instrument, a modular concentric robotic platform, and an augmented reality (AR) navigation interface. The catheter's design balances flexibility for navigating complex intracardiac paths with the rigidity needed for device deployment. The robotic platform's modular architecture enhances versatility, enabling control across various procedures and anatomical variations, while the AR system facilitates intuitive preoperative planning and real-time intraoperative guidance through multimodal image fusion. The core innovation lies in overcoming existing limitations: balancing catheter flexibility and load capacity, expanding robotic system adaptability for different valve procedures, and improving integration with imaging modalities like computed tomography, transesophageal echocardiogram, and fluoroscopy. The project aims to develop sophisticated models for instrument design, control strategies for multi-instrument coordination, and advanced navigation tools. These technological advancements are intended to elevate the clinical utility of robotic intracardiac interventions, making them safer, more efficient, and easier to adopt widely. By establishing a systematic approach for intelligent, multimodal, robotic-assisted valvular procedures, this work promises significant contributions to minimally invasive cardiology and holds substantial potential for clinical translation.

Interventions

Recent advancements in transcatheter therapies have demonstrated promising outcomes for patients with tricuspid valve disease, with transcatheter tricuspid valve replacement (TTVR) emerging as a viable alternative to surgical intervention. The Lux Valve Plus system represents a novel transjugular transcatheter tricuspid valve replacement platform designed to address the unique anatomical challenges of the tricuspid valve. Its transjugular design is advantageous for valve alignment; however, this access route is ergonomically unfavourable for the implanter, increasing radiation exposure compared to a transfemoral approach. Integrating robotic-assisted technology into this platform could potentially reduce radiation exposure, improve ergonomics for operators, and facilitate accurate valve delivery. This research aims to explore the feasibility of robotic transjugular TTVR using the Lux Valve Plus system.

Sponsors

Prince of Wales Hospital, Shatin, Hong Kong
Lead SponsorOTHER
Jenscare Scientific
CollaboratorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 90 Years
Healthy volunteers
No

Inclusion criteria

* Age 18-90 * Severe symptomatic TR * Deem high risk for tricuspid valve surgery determined by a multidisciplinary heart team (including cardiologists, cardiac surgeons and cardiac anesthetists) and * Anatomically feasible for transjugular transcatheter tricuspid valve replacement using the Lux-valve plus system * Able to consent

Exclusion criteria

* Prior TV repair or replacement that would interfere with Lux-valve plus implantation * severe pulmonary hypertension (pulmonary artery systolic pressure \>70 mm Hg or \>2/3 systemic with pulmonary vascular resistance \>5 WU after vasodilator challenge) * Pregnant or nursing patients and those who plan pregnancy during the study period. Female patients of childbearing potential must have a negative pregnancy * Left Ventricular Ejection Fraction (LVEF) \<40% or; * Evidence of intracardiac mass, thrombus or vegetation or; * Anatomical structures precluding proper device deployment or device vascular access, evaluated by echo or CT or; * Surgical correction is indicated for other concomitant valvular disease (e.g., severe aortic, mitral and/or pulmonic valve stenosis and/or regurgitation); Subjects with concomitant valvular disease may treat their respective valve first and wait 2 months before being reassessed for the trial. * Sepsis or active endocarditis within 3 months, or infections requiring antibiotic therapy within 2 weeks prior to the planned procedure or; * Active peptic ulcer or active gastrointestinal (GI) bleeding precluding anticoagulation or antiplatelet therapy or; * Underwent any cardiac or non-cardiac interventional or surgical procedure within 30 days prior to the procedure or planned to have the interventional or surgical procedure within 60 days after implant procedure (e.g., cardioversion, ablation, percutaneous coronary intervention, etc); * Recent (within 90 days prior to procedure) stroke, transient ischemic attack, or myocardial infarction; * Life expectancy is less than 1 year; * Current participation in another investigational drug or device study.

Design outcomes

Primary

MeasureTime frameDescription
Rate of Intraprocedural success according to TVARCIntra-operationTVARC intra-procedural success is defined as: 1. Absence of intraprocedural mortality or stroke; and 2. Successful access, delivery, and retrieval of the device delivery system; and 3. Successful deployment and correct positioning of the intended device(s) without requiring implantation of unplanned additional devices; and 4. Adequate performance of the transcatheter device. Performance of devices whose purpose is a reduction in TR, should include the absence of tricuspid stenosis (TVA \>1.5 cm 2 and mean gradient \<5 mm Hg); reduction of total tricuspid regurgitation to optimal (\<= mild) or acceptable (\<=moderate). 5. Absence of device-related obstruction of forward flow 6. Absence of device-related pulmonary embolism 7. Freedom from emergency surgery or reintervention during the first 24 h related to the device or access procedure
Rate of major adverse events: cardiovascular mortality30 day post-operationrate of cardiovascular mortality at 30 days post-operation
Rate of major adverse events: myocardial infarction30 day post-operationrate of myocardial infarction at 30 days post-operation
Rate of major adverse events: stroke30 day post-operationrate of stroke at 30 days post-operation
Rate of major adverse events: renal complication30 day post-operationRate of renal complications requiring unplanned dialysis or renal replacement therapy at 30 days post-operation
Rate of major adverse events: severe bleeding30 day post-operationrate of severe bleeding at 30 days post-operation
Rate of major adverse events: nonelective Tricuspid Valve reintervention30 day post-operationrate of nonelective Tricuspid Valve reintervention at 30 days post-operation
Rate of major adverse events: major vascular complications30 day post-operationrate of major vascular complications at 30 days post-operation
Rate of major adverse events: major cardiac structural complications30 day post-operationrate of major cardiac structural complications at 30 days post-operation
Rate of major adverse events: device-related pulmonary embolism30 day post-operationrate of device-related pulmonary embolism at 30 days post-operation

Secondary

MeasureTime frameDescription
Device success rateintra-operationRate of Device success defined as device deployed and delivery system retrieved as intended intra-operation
Operation durationintra-operationOperation duration defined as Device at RA to Delivery system recaptured to sheath during operation
Overall Procedural Timeintra-operationOverall Procedural Time defined as time used from obtaining Vascular Access to Closure
Fluoroscopy Timeintra-operationFluoroscopy Time of primary TV implantation
Radiation Dose to Primary Operatorimmediately post-operationRadiation Dose to Primary Operator during index valve implant procedure
Rate of 30-day Clinical Success30-day post-operationRate of 30-day Clinical Success according to TVARC definition at 30-day post-operation
NYHA functional classification30-day post-operationNYHA functional classification at 30-day post-operation
6-minute walk distance30-day post-operation6-minute walk distance at 30-day post-operation
Result of Kansas City Cardiomyopathy Questionnaire30-day post-operationResult of Kansas City Cardiomyopathy Questionnaire at 30-day post-operation
Clinical success according to TVARC criteria at 1 year1-year post-operation1-year Clinical success according to TVARC criteria

Countries

Hong Kong

Contacts

CONTACTDaniel Xu
xjldaniel@gmail.com852 35051518

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Apr 8, 2026