Feasibility Study of the Flash-Sole: A Wearable Midsole With Soft Actuators for Walking Assistance

Feasibility of Flash-Sole in Human Trials: An Active Midsole Powered by Stacked Dielectric Elastomer Actuators for Push-Off Assistance

Status
Not yet recruiting
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT07507006
Acronym
Flash-Sole
Enrollment
10
Registered
2026-04-02
Start date
2026-07-15
Completion date
2026-09-30
Last updated
2026-04-02

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Motor Function

Keywords

Assistive Walking Device, Robotic Footwear, Gait Support, Wearable Technology

Brief summary

The goal of this clinical trial is to test a new shoe device called Flash-Sole. The Flash-Sole is designed to help support the ankle while walking. It was developed by researchers at the University of Nebraska at Omaha. The device uses soft materials and electrical signals to gently assist with foot movement. The main questions this study aims to answer are: * Is the Flash-Sole safe to wear? * Is it comfortable for users? * Does it work as intended to assist walking? This study will include up to 15 healthy adults between the ages of 19 and 45. The Flash-Sole is considered investigational and is not approved by the U.S. Food and Drug Administration (FDA). Participants will: * Complete one visit at the Biomechanics Research Building that lasts about 2 hours * Answer a few health questions to make sure they can join the study * Do short walking trials wearing their own shoes * Wear special shoes with the Flash-Sole device * Walk short distances on a treadmill at a comfortable speed while the device is turned on and off * Wear small, sticky sensors on their legs to measure movement and muscle activity * Wear a safety harness to prevent falls * Complete a short survey about how the shoes felt and how easy they were to use The purpose of this early study is to learn how the device performs and how people feel about wearing it. The results may help guide improvements to the device and inform future studies. This research is not testing whether the device helps people with walking problems yet, but it may lead to that kind of research in the future.

Detailed description

This study evaluates the feasibility, usability, and functional performance of the Flash-Sole, a novel wearable robotic midsole developed at the University of Nebraska at Omaha (UNO). The Flash-Sole is powered by stacked dielectric elastomer actuators and designed to provide gentle push-off assistance during walking. This early-stage trial focuses on determining whether the Flash-Sole system can be safely and comfortably worn by healthy adults and whether it functions as intended in a laboratory environment. The study uses a single-session, within-subject design with up to 15 participants. Each participant will complete walking trials in both baseline conditions (standard shoes) and experimental conditions (Flash-Sole shoes with the system either active or inactive). The research will compare gait parameters and user feedback across these conditions. No control group or randomization is used, as this study is exploratory and not powered to assess clinical outcomes. During the single session (\ 2 hours), participants will: * Complete screening for eligibility * Perform short walking tasks in standard shoes and Flash-Sole shoes * Walk on a treadmill at a self-selected comfortable speed * Wear surface EMG and IMU sensors to measure muscle activity and movement * Provide subjective feedback via standardized usability questionnaires (e.g., System Usability Scale and QUEST 2.0) The primary outcomes of interest include system functionality (e.g., successful actuator activation), usability (System Usability Scale score), and user-reported comfort and ease of use (QUEST 2.0). Secondary outcomes include basic gait characteristics (e.g., cadence, step length) and participant-reported adverse effects, if any. All walking trials will be short (approximately one minute per trial), conducted with rest breaks between trials as needed. A fall-prevention safety harness will be worn at all times. No investigational drugs or implanted devices are used. The Flash-Sole system is investigational and not approved by the U.S. FDA. The study is not conducted under an IDE. Data will be analyzed using descriptive statistics to characterize usability, comfort, and functional performance metrics. Due to the small sample size and feasibility nature of the study, inferential statistics will be limited and exploratory only. This study is intended to inform future device refinements and guide the development of subsequent clinical trials involving individuals with walking impairments, such as stroke survivors or children with cerebral palsy.

Interventions

DEVICEFlash-Sole midsole device

The Flash-Sole is a wearable robotic midsole powered by dielectric elastomer actuators (DEAs). It is embedded in custom footwear and designed to provide ankle push-off assistance during walking. The device operates in two modes: powered (assistance on) and unpowered (assistance off), allowing researchers to assess its mechanical support and user comfort in both states.

Sponsors

University of Nebraska
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DEVICE_FEASIBILITY
Masking
NONE

Masking description

This study is not masked. Both the participant and study team are aware of the intervention being used (Flash-Sole device on or off). The nature of the device and walking protocol makes blinding impractical.

Intervention model description

All participants will complete the same walking trials with and without the Flash-Sole device in a single study session. There is no control or comparison group.

Eligibility

Sex/Gender
ALL
Age
19 Years to 45 Years
Healthy volunteers
Yes

Inclusion criteria

1. Age: 19 to 45 years old at the time of consent 2. Able to understand study procedures and provide informed consent 3. Able to walk independently without assistive devices 4. Willing to wear the Flash-Sole device and complete gait trials during a single session 5. Body weight under 80 kg to comply with device safety specifications

Exclusion criteria

1. Current or recent (within 6 months) lower-limb injury, surgery, or fracture 2. History of neurologic, musculoskeletal, or cardiovascular conditions affecting gait 3. Skin conditions, open wounds, or known allergies at the foot/ankle that interfere with device wear 4. Use of implanted electronic medical devices (e.g., pacemakers, neurostimulators) 5. Cognitive or language impairments that preclude informed consent or task participation 6. no medication related to musculoskeletal condition (e.g., pain relief medications or similar treatments) .

Design outcomes

Primary

MeasureTime frameDescription
Successful Activation of Flash-Sole Device Across Timing ConditionsDay 1 (single-session, during each 1-minute walking trial)This measure assesses whether the Flash-Sole device can reliably detect late-stance gait phases and trigger actuator activation without malfunction. Gait-phase detection and actuation success will be quantified as the percentage of walking trials with accurate and timely device triggering during treadmill walking. Unit of Measure: Percentage of successful trials (%)

Secondary

MeasureTime frameDescription
Adverse Events and Device-Related DiscomfortThroughout the 2-hour study session on Day 1Incidence of any device-related adverse events, including physical discomfort, perceived instability, tripping risk, or device malfunction. Events will be monitored throughout the session using observation and participant verbal reports. Unit of Measure: Number of events
Perceived Usability (System Usability Scale)Immediately following the final walking trial on Day 1Participant-perceived usability of the Flash-Sole will be assessed using the System Usability Scale (SUS), a standardized 10-item instrument. Each item is scored on a 5-point Likert scale, producing a total score from 0 to 100. Higher scores reflect greater perceived usability. Unit of Measure: SUS Score (0-100; higher = better usability)
Comfort and Satisfaction (QUEST 2.0)Immediately following the final walking trial on Day 1Participant-perceived comfort and satisfaction with the Flash-Sole device will be evaluated using the Quebec User Evaluation of Satisfaction with Assistive Technology (QUEST 2.0). Items are rated on a 5-point scale from 1 (not satisfied at all) to 5 (very satisfied), with higher scores indicating greater satisfaction. Unit of Measure: QUEST 2.0 score (1-5 per item; higher = more satisfied)

Countries

United States

Contacts

CONTACTResearch Coordinator, PhD
smohammadi@unomaha.edu402-554-3228
PRINCIPAL_INVESTIGATORAhad Behboo

University of Nebraska

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Apr 3, 2026