Skip to content

Prediction of Post-Induction Hypotension Using Plethysmographic Variability Index During Diagnostic Laryngoscopy

Prediction of Post-Induction Hypotension Using the Plethysmographic Variability Index in Patients Undergoing Diagnostic Laryngoscopy Under General Anesthesia

Status
Not yet recruiting
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT07458893
Enrollment
110
Registered
2026-03-09
Start date
2026-08-15
Completion date
2027-02-10
Last updated
2026-08-03

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Post-Induction Hypotension

Brief summary

This prospective observational study aims to evaluate whether non-invasive hemodynamic parameters, including the plethysmographic variability index (PVI) and perfusion index (PI), can predict post-induction hypotension in patients undergoing diagnostic direct laryngoscopy under general anesthesia. Patients aged 18-75 years with ASA physical status I-III scheduled for elective direct laryngoscopy will be included. PVI and PI values will be recorded before anesthesia induction and in the early post-induction period. The relationship between these indices and the decrease in mean arterial pressure after induction will be analyzed to determine their predictive value for hypotension.

Detailed description

Post-induction hypotension is a common hemodynamic complication during the early phase of general anesthesia and may lead to adverse perioperative outcomes, particularly in patients with limited physiological reserve. Early identification of patients at risk for hypotension may allow clinicians to implement preventive strategies and optimize perioperative hemodynamic management. Recently, non-invasive perfusion-related parameters derived from pulse oximetry have gained attention as potential indicators of intravascular volume status and cardiovascular responsiveness. The plethysmographic variability index (PVI) is a dynamic parameter reflecting respiratory variations in the perfusion index and is considered a non-invasive surrogate marker of fluid responsiveness. The perfusion index (PI), which represents the ratio of pulsatile to non-pulsatile blood flow in peripheral tissues, provides information about peripheral perfusion and vascular tone. These indices are continuously and non-invasively obtained using pulse oximetry and may offer clinically useful information regarding hemodynamic status during anesthesia induction. Direct laryngoscopy performed under general anesthesia may be associated with significant hemodynamic fluctuations during both the induction phase and airway manipulation. Identifying reliable non-invasive predictors of blood pressure reduction during this period may improve intraoperative monitoring and facilitate early intervention.

Interventions

DEVICEPlethysmographic Variability Index (PVI) and Perfusion Index (PI) Monitoring

Non-invasive monitoring of plethysmographic variability index (PVI) and perfusion index (PI) will be performed using pulse oximetry during the peri-induction period in patients undergoing diagnostic direct laryngoscopy under general anesthesia. These parameters will be recorded before anesthesia induction and during the early post-induction phase to evaluate their association with changes in mean arterial pressure and their predictive value for post-induction hypotension.

Sponsors

University of Gaziantep
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to 75 Years
Healthy volunteers
No

Inclusion criteria

* Scheduled to undergo elective direct laryngoscopy under general anesthesia Body mass index (BMI) between 18 and 40 kg/m² ASA physical status classification I-III Provision of written informed consent after being informed about the study

Exclusion criteria

* Severe arrhythmias Advanced heart failure Severe valvular heart disease Preoperative shock or hemodynamic instability requirement for continuous vasopressor or inotropic infusion Significant peripheral vascular disease affecting peripheral circulation

Design outcomes

Primary

MeasureTime frameDescription
Change in Mean Arterial Pressure (ΔMAP) After Anesthesia Induction and Its Association With Plethysmographic Variability Index (PVI) and Perfusion Index (PI)From baseline before induction to 5 minutes after anesthesia induction.The relationship between plethysmographic variability index (PVI) and perfusion index (PI) values measured during the peri-induction period and the change in mean arterial pressure (ΔMAP) after anesthesia induction will be evaluated.

Contacts

CONTACTElzem Sen, Assoc Prof
drelzemsen@gmail.com+905327842151
CONTACTMerve D Yılmaz, Dr
mervedeniztkmn@hotmail.com+905454253505
PRINCIPAL_INVESTIGATORElzem Sen, Assoc Prof

University of Gaziantep

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Aug 4, 2026