Skip to content

Comparative Effects of MIIT With CT In Post-MVR Surgery Patients

Comparative Effects Of Moderate Intensity Interval Training With Continuous Training On Physical Capacity, Pulmonary Functions, Cardiac Efficiency And Quality Of Life In Post Mitral Valve Replacement Surgery Patients

Status
Completed
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT07438717
Enrollment
56
Registered
2026-02-27
Start date
2024-02-10
Completion date
2025-01-05
Last updated
2026-02-27

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Mitral Valve Replacement

Keywords

Cardiac efficiency, continuous training, mitral valve replacement, moderate-intensity interval training, physical capacity, pulmonary function, quality of life

Brief summary

Mitral Valve Replacement (MVR) surgery is commonly performed to treat patients with severe mitral valve diseases, such as mitral stenosis or regurgitation. Patients after mitral valve replacement surgery often experience muscular weakness ,fatigue and reduced functional capacity due to the surgical procedure and the time period of post-operative recovery. A structured exercise program helps rebuild strength and regain mobility, allowing patients to perform daily activities with greater ease and independence. Moderate-intensity interval training (MIIT) with continuous training is crucial for patients after mitral valve replacement (MVR) surgery, as it significantly enhances cardiopulmonary fitness. But the comparative effects of Moderate-intensity interval training (MIIT) with continuous training have not been well documented and practiced in Pakistan. The study aims to determine the comparative effects of Moderate-intensity interval training (MIIT) and moderate continuous training on physical capacity, cardiac efficiency, pulmonary function, and quality of life after mitral valve surgery. The study will be single blinded, randomized clinical trial. Based on inclusion and exclusion criteria patients were divided into two groups. The MIIT group and MICT group. The study was of 12 weeks session, 3 sessions per week (3 months). The data was analyzed through SPSS-23. Outcome measures were pulmonary function tests (spirometery), 6-Minute Walk Test (6MWT) and quality of life assessed through IPAQ. Cardiac efficiencywas measured by evaluating heart rate recovery, exercise tolerance, and cardiac output.

Interventions

Duration: The program lasted 12 weeks with 3 sessions per week. Session Structure: * Each session lasted 20-45 minutes. * Exercise intensity was set at 50-70% of maximum heart rate (MHR). * Intervals consisted of 1-4 minutes of moderate-intensity exercise, followed by shorter rest periods of 1-2 minutes. Exercise Type: * Alternating aerobic activities targeting both upper and lower body, such as treadmill and walking. * A warm-up (5-10 minutes) and cool-down (5-10 minutes) with light stretching and low-intensity walking were included.

Duration: The program lasted 12 weeks with 3 sessions per week. Session Structure: * Each session lasted 30-60 minutes at a steady moderate intensity. * Exercise intensity was maintained at 50-70% of MHR without interruptions. Exercise Type: * Continuous aerobic activity, such as walking on a treadmill. * A warm-up (5-10 minutes) and cool-down (5-10 minutes) were included.

Sponsors

Riphah International University
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
SUPPORTIVE_CARE
Masking
SINGLE (Subject)

Eligibility

Sex/Gender
ALL
Age
40 Years to 60 Years
Healthy volunteers
Yes

Inclusion criteria

* Both male and female age 40-60 years * Hemodynamically stable heart rate and blood pressure * Patients 4-8 weeks post-mitral valve replacement (MVR) surgery * Stable medical condition for MIIT * Able to walk independently for at least 5 minutes without assistance * Stable pulmonary function without severe pulmonary complications (e.g., severe chronic obstructive pulmonary disease). * No ongoing respiratory infections or severe heart failure.

Exclusion criteria

* Presence of unstable angina, severe heart failure (ejection fraction \< 30%), or other significant cardiac arrhythmias that contraindicate exercise. * Conditions that limit mobility or the ability to perform exercises safely (e.g., severe arthritis, recent fractures, or neuromuscular diseases). * Patients with severe respiratory conditions (e.g., severe asthma or COPD exacerbation) that would limit participation in exercise. * Other serious co-morbidities (e.g., uncontrolled diabetes, severe hypertension, renal failure) that may impact safe participation in exercise. * Participation in any other structured exercise program

Design outcomes

Primary

MeasureTime frameDescription
6MWT12 weekThe 6-Minute Walk Test (6MWT) is a functional exercise capacity test which is validated and is able to measure a patient's walking ability for six minutes considering the maximum distance covered. It reflects the capacity for aerobic activity and endurance which is why it is mostly used in cardiac rehabilitation. The test is straightforward, cheap and requires no special equipment in a doctor's office. The reliability of the 6MWT
Digital Spirometer12 weekSpirometry is a common and essential pulmonary function test that measures the volume of air a person can inhale and exhale, as well as how quickly they can do so. It helps in diagnosing and monitoring respiratory diseases, such as asthma, chronic obstructive pulmonary disease (COPD), and other conditions that affect lung function. The reliability is usually good with test results reproducibility generally being above 90%. The validity is also well-defined since spirometry is rated as gold standard of measuring the lung functioning.
VO₂ Peak12 weeksCardiac Efficiency is defined as the heart's capability to pump blood in a manner that requires the least possible effort and still guarantees the tissues receive a good supply of oxygen. The most important indicator of cardiac efficiency is Peak Oxygen Uptake (VO₂ Peak) which comes from a cardiopulmonary exercise test (CPET) that is done under controlled conditions.
IPAQ12 weeksThe IPAQ (International Physical Activity Questionnaire) is the tool that is mostly adopted to evaluate quality of life via physical activity assessment. The IPAQ is made up of 7 queries which ask about the duration of the physical activities, very light to heavy, that happened in the last 7 days

Countries

Pakistan

Contacts

PRINCIPAL_INVESTIGATORHafiza Muriam Ghani, MS-CPPT

Riphah International University

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 28, 2026