Skip to content

Measurement of Expiratory Gas Temperature in Intubated Patients to Estimate Expiratory Absolute Humidity

Measurement of Expiratory Gas Temperature in Intubated Patients to Estimate Expiratory Absolute Humidity

Status
Not yet recruiting
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT07420673
Enrollment
70
Registered
2026-02-19
Start date
2026-04-01
Completion date
2027-06-01
Last updated
2026-02-19

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Mechanical Ventilator Care

Keywords

humidification, Passive humidification

Brief summary

Adequate humidification is essential for intubated patients because dry medical gases can cause thick secretions and dangerous endotracheal tube blockages. A clear correlation exists between exhaled and inhaled humidity delivered by heat and moisture exchanger. The objective of this study is to measure the temperature of exhaled gases in intubated patients in order to accurately calculate the absolute humidity during the expiratory phase. These data will allow for a more accurate reproduction of real clinical conditions during bench testing and will improve the assessment of heat and moisture exchanger performance device evaluation.

Detailed description

Previous clinical studies suggest that real expiratory humidity in intubated patients is close to 35 mg H₂O/L, with expiratory temperatures around 32-33 °C or slightly lower. However, data are limited, heterogeneous, and often derived from anesthetized patients. Therefore, accurate measurement of expiratory temperature in intensive care patients under normothermia and across varying body temperatures is necessary to define realistic simulation standards and ensure reliable heat and moisture exchanger performance evaluation on a bench. A relationship between expiratory gases temperature and expiratory humidity exist.

Interventions

OTHERExpiratory gases temperature

Measure expiratory gas temperature immediately before the passive humidifier in intubated ICU patients and evaluate the relationship between body temperature and expiratory temperature.

Sponsors

Laval University
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Adults (≥18 years) * Intubated and mechanically ventilated in the intensive care unite * Using passive humidification (Heat and Moisture exchanger)

Exclusion criteria

* PEEP set \< 12 cmH₂O * Inhaled nitric oxide therapy * Tracheostomy

Design outcomes

Primary

MeasureTime frameDescription
Expiratory gas temperatureH0, up to 60 minutes after inclusionMeasure expiratory gas temperature immediately before the passive humidifier
Relationship between body temperature and expiratory temperature.H0, up to 60 minutes after inclusionEvaluate the relationship between body temperature and expiratory temperature

Secondary

MeasureTime frame
Estimate expiratory absolute humidity based on measured temperatureH0, up to 60 minutes after inclusion

Countries

Canada

Contacts

CONTACTFrancois Lellouche, MD, PhD
francois.lellouche@criucpq.ulaval.ca1 418-656-8711

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 20, 2026