Skip to content

Supervised Endoscopic Tele-controlled Intelligent Lithotripsy

A Feasibility Trial of a Novel Robotic System for Retrograde Intrarenal Surgery

Status
Recruiting
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT07411391
Acronym
SENTINEL-1
Enrollment
15
Registered
2026-02-13
Start date
2026-02-15
Completion date
2027-03-31
Last updated
2026-04-24

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Renal Stone

Keywords

Renal stone, Urolithiasis, RIRS, Flexible URS, Supervised autonomy

Brief summary

This is a phase I feasibility study to investigate the use of a novel intelligent robotic retrograde intrarenal surgery (RIRS) platform. The TaloStone T1000 RIRS system can manipulate the flexible ureteroscope, with remote control of the instruments (laser fibre or basket) and ureteral access sheath movements. Beyond teleoperation, the TaloStone T1000 RIRS system integrates AI perception models and decision-making algorithms to enable the supervised autonomous execution of critical tasks within the RIRS workflow.

Detailed description

I. Introduction Retrograde intrarenal surgery (RIRS) has become a preferred method for the diagnosis and treatment of urological diseases, such as kidney stone removal. However, the complex urinary and limited visibility of existing endoscope lead to inefficient manipulation of flexible ureteroscopes. Besides, conventional flexible ureteroscopy requires repetitive manual manipulation, which often results in surgeon fatigue, mucosa injury from respiratory motion, and variable stone clearance rates, particularly in complex calyceal anatomies. The research focuses on the development of an novel robotic system for RIRS, currently dubbed "TaloStone T1000". The robotic system platform consists of a surgeon control console, a multi-functional video cart, and patient-side robotic arm with fiber-optic-sensitized flexible ureteroscopy as shown in Fig. 1. The surgeon console with optimized design of ergonomics is equipped with haptic master devices for smooth and precise control of the robotic arm to manipulate the flexible ureteroscope as well as instruments, e.g., stone baskets and laser fibers. The system also supports seamless integration of multiple modalities, including pre-operative CT scans, intra-operative endoscopic videos, and fiber-optic sensing. Besides, the self-developed flexible ureteroscope is embedded with fiber optic sensors for real-time shape sensing, force estimation, and simultaneous intrarenal pressure control and temperature monitoring. Shape sensing enables precise navigation of the ureteroscope within the renal collecting system, and force estimation provides accurate feedback of tip contact interaction to the master devices on the surgeon control. Moreover, AI algorithms are incorporated to assist in diagnostics and higher level of supervised surgical autonomy, thereby improving safety and efficiency. The investigators developed AI-powered diagnostics for stone sensing, laser fiber recognition, depth awareness, and CT-to-endoscopy localization. Based on the sensing results from AI-powered diagnostics, the investigators proposed a supervised framework that can automate repetitive procedures throughout in-sheath and ureter navigation, laser approaching, and laser trajectory planning. The entire operation is under supervision of the surgeon, who can use one trigger on the master device or footswitch to enable or disable the supervised automated features. The foot pedal of laser device remains to trigger laser emission by the surgeon for stone fragmentation, dusting, and pop-corning. The basic safety and essential performance of both hardware and software in the robotic system were developed under clinical standards and medical device regulations. To date, a total of three cadaveric studies have been conducted using the robotic system. In August 2024, the investigators performed the first cadaver study of the robotic system at Prince of Wales Hospital (PWH), where user study of ergonomic manners and tele-operation control of stone treatment was investigated. The second and third cadaver studies, focusing on the AI-powered features of the robotic system, were completed at PWH in June and December 2025. Synthetic renal stones of around 3mm were retrogradely inserted to the renal collecting systems, with successful fragmentation via the robotic RIRS system using Holmium:YAG laser. Over 10 doctors from PWH and the Chinese University of Hong Kong, participated in the cadaver studies. The current system response, motion speed of the robotic system, and operations with ergonomic control console can satisfy the requirements of the doctors. In addition to the cadaver studies, the investigators have conducted a set of laboratory testing and experiments, validating its robustness and stability of the system. Subsequent to successful cadaveric experiments, the investigators planned to further validate of the feasibility of the use of the system in clinical cases. In this study, the investigators aim to evaluate the robotic system's safety and feasibility in RIRS in a stage 1, proof of concept study that follows the concepts outlined in the IDEAL framework (Idea, Development, Exploration, Assessment, Long-term Study). II. Methods Aim The aim of this study is to evaluate the feasibility and safety of performing RIRS using the TaloStone T1000 system. Study Design This is a prospective, single-arm study that will be conducted by investigators from The Chinese University of Hong Kong/Prince of Wales Hospital in the period from November 2025 to June 2026. The investigators are experts in endo-urological surgery and robot-assisted surgery. The study design follows the guidelines for stage 1 of the IDEAL framework. The study will be carried out in accordance with the Declaration of Helsinki of the World Medical Association and the International Conference on Harmonization - Good Clinical Practice. The study information will be provided to subjects during a preoperative consultation by the investigators and the research staff. Subjects will be provided with approved informed consent explaining the study procedure, risks, assessments, and required compliance; and will be given ample time to make their decision regarding participation in the study. Perioperative data and outcomes from all cases of those participating in the study will be reviewed by an independent Data and Safety Monitoring Committee (consisting two senior urologists not involved in this study) for safety and identification of serious perioperative complications (within 30 days after the surgery) as interim to safeguard study subjects. The Committee will make periodic recommendations to the study team on whether to continue, modify, or prematurely terminate the study. Any adverse events will also be immediately reported to the Clinical Research Ethics Committee of the hospital. Reporting of this stage 1 study will follow the IDEAL Reporting Guidelines.

Interventions

PROCEDURERIRS using the TaloStone T1000 RIRS platform

Retrograde intrarenal surgery (RIRS) will be performed using the TaloStone T1000 RIRS system. Beyond teleoperation, the TaloStone T1000 RIRS system integrates advanced AI perception models and decision-making algorithms to enable the autonomous execution of critical tasks within the RIRS workflow. The AI-based vision models coupled with sensors in the fURS allow real-time scene understanding, depth perception, stone size estimation, pressure and temperature feedback, and object tracking - thus establishing a robust foundation for higher level of surgical autonomy. Under supervision by the surgeon, the TaloStone T1000 RIRS system can perform supervised navigation into the collecting system, actively track a target stone, dynamically target the laser fibre tip towards a stone, plan the laser fragmentation route, and perform scope withdrawal for stone suction with re-entry.

Sponsors

Chinese University of Hong Kong
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
19 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1. Adult patients \>18 years old 2. Renal stone(s) less than 1cm 2cm in maximal length 3. Clinically indicated for RIRS 4. Willingness to participate as demonstrated by giving informed consent

Exclusion criteria

1. Patients with no preoperative CT imaging available 2. Patients who are not recommended to receive RIRS 3. Severe concomitant illness that drastically shortens life expectancy or increases risk of therapeutic intervention 4. Untreated active infection 5. Un-corrected coagulopathy 6. Presence of another malignancy or distant metastasis 7. Emergency surgery 8. Vulnerable population (e.g. mentally disabled, pregnant)

Design outcomes

Primary

MeasureTime frameDescription
Success rateIntra-operativeSuccessful RIRS by the robotic system, i.e. without conversion to conventional manual RIRS

Secondary

MeasureTime frameDescription
Stone free rateWithin post-operative 1 month* by non-contrast computer tomography (NCCT) performed within 1 month of surgery * without residual stone fragments, or residual stone fragments \<2mm
Operative timeIntra-operative* total operative time (time from start of operation to the end of operation) * console time (from start of control of robotic system to end of control of robotic system) * robotic control time (defined as time spent manipulating the control for navigation) * robotic set-up time (from the moment the robot is pushed into the operating room to the moment the flexible ureteroscope is attached to the robot) * procedure time (total operative time - The robot set-up time) * lasing time
Total laser energy usedIntra-operativeLaser energy in terms of kJ
Total radiation dose during operationIntra-operativeRadiation dose based on fluoroscopy readings
Surgeon radiation exposureIntra-operative\- by radiation dosimeter
Length of hospital stayDuring admission period (up to 30 days)\- days of stay as in-patient
Post-operative painFrom immediately post-operatively to discharge (day 0 to day 1)\- by visual analogue scale, from 0-10 with 10 being the most pain
Post-operative complicationsWithin post-operative 30 daysBy "Clavien-Dindo Classification"
Surgeon questionnairesImmediately post-operative, day 0Completed the Subjective Mental Effort Questionnaire (SMEQ) to assess subjective during RIRS surgery.

Countries

Hong Kong

Contacts

CONTACTAlex Qinyang Liu, MBBS, MSc, FRCSEd
alexliu@surgery.cuhk.edu.hk852+35052625
CONTACTChi Fai Ng, MBChB, MD, FRCSEd
ngcf@surgery.cuhk.edu.hk852+35052625

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Apr 25, 2026