Skip to content

Intraoperative Assessment of Renal Tissue Oxygenation Using NIRS

Intraoperative Assessment of Renal Tissue Oxygenation Using Near-Infrared Spectroscopy During Liver Transplantation and Its Relationship With Hemodynamic Parameters: A Prospective Observational Study

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT07409532
Enrollment
41
Registered
2026-02-13
Start date
2022-12-01
Completion date
2025-08-07
Last updated
2026-02-13

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Liver Transplant, Complications, Renal Failure Acute Chronic

Keywords

NIRS, Liver Transplantation, Renal Function

Brief summary

The kidney is one of the most vital organs in the human body. Renal perfusion is primarily supplied by the renal artery, while the removal of metabolites and venous drainage are provided by the renal vein. Although anatomical variations may exist, the renal artery typically originates from the abdominal aorta. In patients undergoing liver transplantation, renal function may be affected by multiple factors. Impairment of renal function significantly influences postoperative mortality, morbidity, graft survival, and length of hospital stay. Intraoperative assessment of renal perfusion has traditionally relied on monitoring hourly urine output and serum renal function tests. However, these methods may be insufficient and delayed in evaluating renal function, particularly during clamping of the inferior vena cava for hepatic graft venous anastomosis. Although Doppler ultrasonography can provide information regarding blood flow, it does not offer direct insight into the adequacy of tissue perfusion. Near-infrared spectroscopy (NIRS) is a non-invasive technique that has gained increasing attention in recent years due to its ability to accurately assess tissue oxygenation. Based on the Beer-Lambert law, NIRS enables the measurement of tissue oxygen saturation without the need for invasive procedures. The technique requires no intervention and is not associated with known complications or adverse effects. NIRS is most commonly used in clinical practice to assess cerebral oxygenation via measurements obtained from the frontal region. The aim of the present study is to evaluate renal oxygenation using near-infrared spectroscopy and to determine whether this technique provides clinically useful information during the liver transplantation procedure.

Detailed description

Near-infrared spectroscopy (NIRS) is a non-invasive and user-friendly technique that enables real-time monitoring of tissue oxygen content. It is most commonly used in clinical practice to assess cerebral tissue oxygenation, particularly in cardiac surgery, where significant hemodynamic fluctuations are frequently encountered. NIRS measures cerebral tissue oxygen saturation from the frontal region and reflects the balance between local cerebral oxygen supply and demand. Light applied to the forehead is emitted within the near-infrared spectrum and detected by sensors positioned at specific distances from the light source. Using a modified version of the Beer-Lambert law, NIRS provides a measurement of oxygenated hemoglobin concentration relative to total hemoglobin concentration. Algorithms are subsequently applied to the raw data to generate a quantitative estimate of tissue oxygen saturation. Numerous studies have demonstrated a correlation between cerebral desaturation and postoperative neurological complications. Consequently, specific management algorithms have been developed for the use of NIRS in cardiac surgery. In the presence of cerebral desaturation, recommended interventions include correction of cannula positioning, elevation of mean arterial pressure, increasing the inspired oxygen concentration, normalization of PaCO₂ levels, correction of hemoglobin concentration, augmentation of cardiac output, and reduction of cerebral metabolic rate. Renal oxygen supply is primarily provided via the renal artery, while venous drainage occurs through the renal veins into the inferior vena cava. Adequate renal perfusion during liver transplantation is essential to minimize postoperative renal complications. For vascular anastomosis of the liver graft, clamping of the inferior vena cava is required, a process that results in significant hemodynamic alterations and impaired renal venous drainage. These changes may substantially affect renal oxygenation and perfusion. Although renal blood flow adequacy can be indirectly assessed by monitoring urine output after reperfusion, this method does not allow for objective evaluation of renal tissue oxygenation. We hypothesize that intraoperative monitoring of renal tissue oxygenation using NIRS may provide valuable real-time information and contribute to the early identification of postoperative acute kidney injury.

Interventions

None listed

Sponsors

Inonu University
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to 65 Years
Healthy volunteers
No

Inclusion criteria

This prospective observational study was conducted at the Inönü University Liver Transplant Institute between 2022 and 2023, following approval by the Malatya Clinical Research Ethics Committee (Approval No. 2022/118). Inclusion Criteria: * Patients aged 18-65 scheduled for elective liver transplantation. * American Society of Anesthesiologists (ASA) physical status III-IV were enrolled.

Exclusion criteria

* Patients undergoing emergency liver transplantation, * Advanced preexisting renal dysfunction * İndividuals with significant cardiovascular instability

Design outcomes

Primary

MeasureTime frameDescription
Renal O3Measurements were recorded at three predefined surgical phases: • T0: Pre-anhepatic phase (beginning of dissection) • T1: Anhepatic phase (after clamping of the inferior vena cava and portal vein) • T2: Neohepatic phase (after graft reperfusion and complRenal parenchymal oxygen saturation was measured using a Masimo™ NIRS probe enclosed in a sterile sheath. During surgical dissection, the probe was positioned vertically on the Gerota's fascia overlying the kidney.
CrRenal function was evaluated using serum creatinine levels measured preoperatively, at postoperative 24 hours, and at postoperative week 1.Renal function was evaluated using serum creatinine levels

Secondary

MeasureTime frameDescription
HRDuring surgery: • T0: Pre-anhepatic phase (beginning of dissection) • T1: Anhepatic phase (after clamping of the inferior vena cava and portal vein) • T2: Neohepatic phase (after graft reperfusion and completion of vascular anastomoses)Heart Rate
MAPDuring surgery: • T0: Pre-anhepatic phase (beginning of dissection) • T1: Anhepatic phase (after clamping of the inferior vena cava and portal vein) • T2: Neohepatic phase (after graft reperfusion and completion of vascular anastomoses)mean arterial pressure (mmHg) (via invasive arterial pressure monitoring from the radial artery)
CIDuring surgery: • T0: Pre-anhepatic phase (beginning of dissection) • T1: Anhepatic phase (after clamping of the inferior vena cava and portal vein) • T2: Neohepatic phase (after graft reperfusion and completion of vascular anastomoses)Cardiac Index (L/min/m²) (via PICCO flotrac monitoring platform)
SVVDuring surgery: • T0: Pre-anhepatic phase (beginning of dissection) • T1: Anhepatic phase (after clamping of the inferior vena cava and portal vein) • T2: Neohepatic phase (after graft reperfusion and completion of vascular anastomoses)Stroke volume variation (%) (via PICCO flotrac monitoring platform)

Countries

Turkey (Türkiye)

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 14, 2026