Skip to content

An Immediate Implant Will be Placed Using the MiniNaviDent System and Static Guide. A Postoperative CBCT Scan Will Then be Acquired and Superimposed Onto the Preoperative CBCT Scan to Assess and Compare Implant Deviation Relative to the Preoperative Plan

Evaluation of Immediate Implant Placement Accuracy Using a Dynamic Navigation System. "Randomized Clinical Trial"

Status
Completed
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT07380360
Enrollment
20
Registered
2026-02-02
Start date
2024-11-24
Completion date
2025-09-25
Last updated
2026-02-11

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Remaining Root, Tooth Extraction

Keywords

immediate implant, dynamic navigation, static guide, CBCT superimposition, guided implant surgery

Brief summary

This clinical study aims to evaluate implant deviation during immediate implant placement using dynamic navigation. By utilizing implant planning software, two CBCT scans (preoperative and postoperative) will be superimposed to assess the accuracy of dynamic navigation in immediate implant placement, which is considered a more complex procedure compared to delayed implant placement

Detailed description

First, a fiducial marker will be placed in the patient's mouth, followed by a CBCT scan with the marker in position. The implant will then be virtually planned using implant planning software. Using the MiniNaviDent system and the fiducial marker, the implant will be placed. After placement, a postoperative CBCT scan will be obtained. The postoperative scan will be superimposed onto the preoperative scan to measure implant deviation.

Interventions

DEVICEDynamic navigation system-assisted dental implant placement

Dental implant placement performed using a dynamic computer-assisted navigation system with real-time guidance. The implant position is planned pre-operatively using CBCT (and intraoral scan data if applicable). During surgery, the system tracks the patient reference and the drill/handpiece and displays real-time guidance to follow the planned implant trajectory for osteotomy preparation and implant insertion. Device name: mini Navident

DEVICECAD/CAM static surgical guide-assisted dental implant placement

Dental implant placement performed using a patient-specific CAD/CAM static surgical guide. The guide is designed from the digital implant plan (CBCT and, if applicable, intraoral scan) and fabricated (e.g., 3D printed). The static guide (with sleeves) is used to guide osteotomy preparation and implant insertion according to the planned implant position.

Sponsors

Ain Shams University
Lead SponsorOTHER

Study design

Allocation
NON_RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
SINGLE (Outcomes Assessor)

Intervention model description

All participants will receive immediately placed implants following extraction

Eligibility

Sex/Gender
ALL
Age
21 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

1. Healthy patients at least 21 years old. 2. Systemically healthy patients with no effect on the surgery. 3. At least one hopeless maxillary or mandibular tooth to be restored using an implant. 4. At least six residual teeth in the affected jaw.

Exclusion criteria

1. A medical condition or medication that would impair bone healing. 2. Poor oral hygiene 3. Alcohol users. 4. Smoking more than 10 cigarettes per day. 5. History of head and neck radiotherapy. 6. Pregnant females. 7. Uncontrolled hypertensive or diabetic patients.

Design outcomes

Primary

MeasureTime frameDescription
Coronal deviation (mm) Apical deviation (mm)Pre-op CBCT and post-op CBCT within 7 days after surgeryImplant deviation was defined as the discrepancy between the planned implant position (as established in the preoperative planning software) and the actual implant position placed using dynamic navigation and a static surgical guide. To quantify this deviation, the postoperative CBCT was superimposed (registered) onto the preoperative planned CBCT, and the resulting spatial differences between the planned and placed implants were measured and reported in millimeters (mm)
Angular deviation (degrees)Pre-op CBCT and post-op CBCT within 7 days after surgeryImplant deviation was defined as the discrepancy between the planned implant position (as established in the preoperative planning software) and the actual implant position placed using dynamic navigation and a static surgical guide. To quantify this deviation, the postoperative CBCT was superimposed (registered) onto the preoperative planned CBCT, and the resulting spatial differences between the planned and placed implants were measured and reported in and the angular deviation in degrees was measured.

Secondary

MeasureTime frameDescription
Total surgical time (minutes)Intraoperative (day of surgery)Total operative time recorded in minutes from first mucosal incision to completion of final implant insertion (last implant fully seated). Time will be recorded by an independent observer using a stopwatch and compared between the dynamic navigation and Static Guide groups

Countries

Egypt

Outcome results

None listed