Leica Microsystems Sponsored PMCF Study to Collect and Confirm Clinical Data on the Performance of the GLOW400 Device When Used in Accordance With Its Intended Use

Fluorescence Visualization and Image Quality Evaluation of Digital Visualization of Suspected Grade III and/or IV Gliomas During Neurosurgery (Leica GLOW400)

Status
Not yet recruiting
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT07366892
Acronym
IMED-GLOW400
Enrollment
37
Registered
2026-01-26
Start date
2026-02-01
Completion date
2027-05-31
Last updated
2026-01-26

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Glioblastoma (GBM), Glioma, Neurosurgical Procedure, Suspected Grade III and IV Gliomas Requiring Surgical Intervention

Keywords

GLOW400, ARveo8x, Digital surgical microscope, 5-ALA fluorescence, Image quality assessment, Grade III gliomas, Grade IV gliomas, High-grade glioma, fluorescence-guided surgery

Brief summary

This post-market clinical follow-up (PMCF) study aims to confirm the safety and performance of the GLOW400 surgical microscope accessory when used in conjunction with the ARveo8x surgical microscope. The study evaluates fluorescence visualization and image quality during standard surgical procedures in neurosurgery. It is a non-interventional, observational study conducted in routine care settings across multiple European sites.

Detailed description

The IMED-GLOW400 study is a prospective, observational, non-interventional clinical investigation conducted in the European Economic Area and Switzerland. It involves the use of the GLOW400 accessory, which digitally enhances fluorescence signals during neurosurgery, providing improved anatomical visualization and contrast. The study compares GLOW400 with the benchmark FL400 optical filter system. The primary objective is to confirm the image quality and fluorescence visualization performance of GLOW400. Secondary objectives include validating product claims and assessing user experience and safety. An exploratory objective evaluates the extent of tumor resection using volumetric analysis of pre- and post-operative MRI scans. Data will be collected through structured questionnaires, histopathology confirmation, optional resection forms, and intraoperative video recordings. The study will enroll 37 patients, with at least 29 complete datasets required for analysis. The duration of the study is estimated at 5 to 6 months, with each patient participating only during the surgical procedure. The study complies with ISO 14155:2020, GDPR, and the Declaration of Helsinki. Ethics Committee approval and informed consent are mandatory prior to enrollment. No additional procedures beyond standard of care are introduced, and risks are limited to those associated with routine surgical practice.

Interventions

DEVICEGLOW400 is a digital surgical microscope accessory used in fluorescent visualization of suspected grade III or IV gliomas during neurosurgery.

The digital surgical microscope accessory GLOW400 is using the optical excitation and emission filtering of the FL400. The FL400 provides an illumination filter (380nm - 430nm) which when engaged into the light source path of the surgical operating microscope provides, via a light guide, a fluorescence excitation light system used in conjunction with an approved tumor-selective substance (fluorophore) (e.g. Protoporphyrin IX (PpIX) which is resulting of the metabolization of 5-ALA (5 - aminolaevulinic acid)) for tissue characterization in the open neurosurgery field. PpIX is strongly fluorescent with a peak at λ=635 nm as red-violet after excitation with blue light (λ=380-410 nm). The digital surgical microscope accessory GLOW400 is using the optical excitation and emission filtering of the FL400. The fluorescence signal visualized depicts the distribution of the dye in the patient's tissues during the surgical procedure.

Sponsors

Leica Microsystems (Schweiz) AG
Lead SponsorINDUSTRY

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

Candidates for the for the IMED-GLOW400 Study must be appropriate patients for surgical interventions with suspected intracranial high-grade glioma evidenced by preoperative imaging modalities and have to fulfil all of the following inclusion criteria to be eligible for the recruitment of the study. Inclusion Criteria 1. Participants must be 18 years of age or older at the time of signing the informed consent. 2. Participants must have suspected high-grade glioma (WHO grade III-IV) as evidenced by preoperative imaging modalities, which require surgical intervention. 3. The active substance 5-aminolevulinic acid (5-ALA) fluorescence dye is administered according to the 5-ALA instructions for use. 4. The participant or their legal representative must understand the study and have voluntarily signed and dated the Informed Consent Form, which has been approved by the Sponsor and the Ethics Committee for this study. Note for Switzerland only: Enrollment via legal representative is not permitted. Therefore, only patients who are capable of providing informed consent themselves will be eligible for inclusion in Switzerland.

Exclusion criteria

1. Known allergy to 5-ALA hydrochloride or protoporphyrin. 2. Patients with porphyria (a condition characterized by the inability to break down protoporphyrin). 3. Any uncontrolled systemic condition that may adversely affect the surgical outcome. 4. Patients holding United States citizenship.

Design outcomes

Primary

MeasureTime frameDescription
Flourescence visibilityPeriproceduralPerformance will be evaluated using Questionnaire, a structured Likert-scale survey completed by the operating surgeon during and after surgery. The questionnaire assesses: 1. perceived intensity of fluorescence 2. perceived volume/ shape and relative location 3. perceived distribution of fluorescence 4. anatomical and fluorescence observation (GLOW400 Anatomy only) Each item is rated on a 5-point Likert scale: 1. = Not available 2. = Insufficient 3. = Sufficient 4. = Very good 5. = Excellent Higher scores indicate better performance. The outcome is considered acceptable if all ratings are ≥3 (Sufficient or better).
Image qualityPeriproceduralPerformance will be evaluated using Questionnaire, a structured Likert-scale survey completed by the operating surgeon during and after surgery. The questionnaire assesses:: 1. Stereoscopic Perception (3D Depth perception) 2. Resolution 3. Noise 4. Latency Each item is rated on a 5-point Likert scale: 1. = Not available 2. = Insufficient 3. = Sufficient 4. = Very good 5. = Excellent Higher scores indicate better performance. The outcome is considered acceptable if all ratings are ≥3 (Sufficient or better).
Anatomy of the brain, including Vessels (GLOW400 Anatomy only)PeriproceduralPerformance will be evaluated using Questionnaire, a structured Likert-scale survey completed by the operating surgeon during and after surgery. The questionnaire assesses: 1. Neuroanatomy structures 2. Vascular structures 4. Perceived contrast (GLOW400 HiFluo only) 5. Bleeding visibility (GLOW400 Anatomy only) 6. Traces of remaining fluorescence (GLOW400 HiFluo only) Each item is rated on a 5-point Likert scale: 1. = Not available 2. = Insufficient 3. = Sufficient 4. = Very good 5. = Excellent Higher scores indicate better performance. The outcome is considered acceptable if all ratings are ≥3 (Sufficient or better).

Secondary

MeasureTime frameDescription
The secondary objectives of this Post-Market Clinical Follow-up (PMCF) study are to assess the continued safety of the device.PostoperativelySafety will be evaluated using Questionnaire B, completed postoperatively by the surgical team. It captures: 1. Dizziness through using digital 3D visualization 2. Delayed, interrupted or hindered surgery due to different causes 3. Occurred injuries to the patient 4. Breach of sterility 5. Any patient or user tissue burn event reported. 6. Confirm user experience with the use of the device in real clinical practice, supporting the marketing claims: 1. Confidence in decision 2. Focus during procedure 3. Surgical course of action 4. User experience 5. Mental fatigue Responses are binary: 1. = Yes (event occurred) 2. = No (event did not occur) Lower scores (2 = No) indicate better safety outcomes. The outcome is acceptable if no safety events are reported.