Skip to content

Optimizing Hemodialysis: How Low Dialysate Flow Alters Adequacy and Patient Recovery.

Low Dialysate Flow: Its Effect on Hemodialysis Adequacy, Dialysis Recovery Time and Patient Reported Outcome Measures.

Status
Completed
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT07360769
Enrollment
80
Registered
2026-01-22
Start date
2025-06-01
Completion date
2025-09-30
Last updated
2026-01-22

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

End Stage Kidney Disease (ESRD)

Brief summary

The goal of this clinical trial is to detect if lower dialysate flow rate can affect hemodialysis adequacy , dialysis recovery time and patients quality of life. The main questions it aims to answer are: does low dialysate flow affect hemodialysis adequacy? does green dialysis achievable without affecting hemodialysis adequacy? Researchers will compare hemodialysis session of high dialysate flow to that with low dialysate flow. Participants will: underwent hemodialysis for a week with low dialysate flow and another week with high dialysate flow.

Interventions

OTHERlower dialysate flow rate ( 300ml/min). then testing its effect on hemodialysis adequacy

The aim of this study is to check whether change of dialysate flow from 500ml/min to 300ml/min has a significant impact on dialysis adequacy , dialysis recovery time and patient reported outcome measures in maintenance hemodialysis patients.

Sponsors

Alexandria University
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* ESKD patients more than or equal 18 years old, on maintenance HD thrice weekly for more than three months and each session lasts for 4 hours. * All patients will receive HD via an arterio-venous fistula. * All patients will receive HD via the same type of HD machine and the blood pump will be set at 300ml/min. * All patients will receive the same type of HD membranes and every effort will be made to achieve the dry weight of the patients.

Exclusion criteria

: * Critically ill and hospitalized ESKD patients. * Mentally disabled patients. * Patients with terminal malignancy or receiving chemotherapy. * Patients receiving immune suppression treatment.

Design outcomes

Primary

MeasureTime frame
The change of dialysate flow rate, for three successive conventional hemodialysis sessions, from 500ml/min to 300ml/min and its impact on hemodialysis adequacy that is assessed by urea reduction ratio (URR).Two weeks
The change of dialysate flow rate, for three successive conventional hemodialysis sessions, from 500ml/min to 300ml/min and its impact on hemodialysis adequacy that is assessed by and single-pool Kt/V (spKt/V) using the Daugirdas formula.Two weeks

Secondary

MeasureTime frame
The effect of lowering dialysate flow rate from 500ml/min (milli per minute) to 300ml/min on dialysis recovery time (DRT) in minutes. Longer duration indicates lower dialysis adequacy.two weeks
The patients reported outcome measures that is assessed by palliative care Outcome Scale - Symptoms Renal (POS S renal). Each symptom takes a score from zero to four (0-4), high score indicates less efficient dialysis.Tow weeks

Countries

Egypt

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026