Efficacy and Safety of Micra AV2 Transcatheter Pacing System

Efficacy and Safety of Micra AV2 Transcatheter Pacing System

Status
Recruiting
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT07356505
Acronym
EMAV2
Enrollment
150
Registered
2026-01-21
Start date
2026-01-12
Completion date
2029-01-31
Last updated
2026-01-21

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

AV Block, AV Block-2Nd Degree-Type 1, AV Block Complete

Keywords

leadless pacemaker, Micra AV, AV synchrony

Brief summary

A third generation, Micra AV2 is now available and proposes increased automaticity and improved AV synchrony algorithms based on computing model. The new algorithms permit the delivery of AV synchronous pacing, improving the automatic AV synchrony at faster heart rates between 80-100 bpm with a maximal upper tracking rate limit of 135 bpm (previously 115-120 bpm in the Micra AV1). Micra AV2 presents also a potential extended longevity of 15.6 years (increased by \> 44% in comparison of Micra AV1). Up to now, no clinical study has evaluated the efficacy and safety of Micra AV2 in a real-world setting. The focus of this study is to characterize chronic ambulatory AV synchrony in patients with high degree AV block and normal sinus rhythm implanted with a Micra AV2 as primary objective to evaluate AV synchrony during exercise as secondary objective.

Detailed description

Prospective, single-arm, multi-centre clinical study to characterize the chronic efficacy and safety profile of CE approved and market released Micra AV2 A sample size of approximately 150 subjects implanted with a Micra AV2 is required to evaluate the different objectives. A minimal sample size of 50 subjects with persistent 3rd degree AVB and normal sinus node function is required to evaluate the ambulatory AV synchrony at 6-month follow-up. Primary objective: Characterize ambulatory AV synchrony in subjects with persistent third degree AV block and normal sinus node function at 6-month post Micra AV2 implant procedure Secondary objective(s): 1. Characterize the AV synchrony and device behaviour during exercise in subjects with persistent third degree AV block and normal sinus node function at 6-month post implant procedure 2. Characterize the evolution of left ventricular function at 12-month post implant 3. Evaluate the efficacy of the 'Atrial Sensing Setup' at the end of the implant procedure 4. Long-term follow-up (3 years) to evaluate AV synchrony, need for system revision and complication rate including rate of pacing induced cardiomyopathy

Interventions

DEVICEImplant procedure of a Micra AV2 leadless pacemaker (Medtronic)

All patients will be implanted with aMicra AV2 leadless pacemaker

Sponsors

Universitaire Ziekenhuizen KU Leuven
Lead SponsorOTHER
Medtronic
CollaboratorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1. Voluntary written informed consent of the participant or their legally authorized representative has been obtained prior to any screening procedures 2. At least 18 years of age at the time of signing the Informed Consent Form (ICF) 3. Participant will be implanted with a Micra AV2 for an approved indication for use 4. Participant with a history of any type of high-degree AV block 5. Participant is willing and able to comply the study protocol

Exclusion criteria

-1. Subject implanted with a Micra AV2 on a non-permanent basis (e.g. CIED infection) 2. Subject is pregnant (if required by local law, women of child-bearing potential must undergo a pregnancy test within seven days prior to Micra AV2 implant procedure) 3. Subject currently enrolled or planning to participate in a potentially confounding drug or device trial during the study. 4\. Subject meets any

Design outcomes

Primary

MeasureTime frameDescription
AV synchrony at 6 months6 months follow-upAV synchrony will be computed on an individual heartbeat basis and is defined as met for paced or sensed ventricular beats that are within 300 ms following an ECG confirmed P-wave. This endpoint will be used for the primary objective , for the secondary objective #1 (AV synchrony during exercise at 6-month post-implant) and for the secondary objective #3 (evaluation of the AV synchrony following the automated atrial sensing setup)