Skip to content

Post-Market Study of the Signia Circular Stapler With Tri-Staple Technology in Left-sided Colon, Sigmoid, and Rectal Resections

A Prospective, Multicenter, Single-arm, Post Market Study to Evaluate the Safety and Performance of the Signia™ Circular Stapler With Tri-Staple™ Technology in Elective Open or Minimally Invasive Left-sided Colon, Sigmoid, and Rectal Resections (SECURE)

Status
Recruiting
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT07351071
Acronym
SECURE
Enrollment
137
Registered
2026-01-20
Start date
2025-12-30
Completion date
2027-06-30
Last updated
2026-09-01

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Anastomotic Complication, Anastomotic Leak, Anastomotic Leaks, Colonic Diseases, Colorectal Anastomosis, Digestive System Diseases, Gastrointestinal Diseases, Intestinal Diseases, Left-sided Colon Resection, Postoperative Complications, Rectal Diseases

Keywords

Colorectal Anastomosis, Left-sided Colon Resection, Circular stapler, Anastomotic Leak, Rectal cancer, Low anterior resection, Powered stapler

Brief summary

The purpose of this study is to evaluate the safety and performance of the Signia™ power handle, Signia™ circular adapter, and Signia™ Tri-Staple™ 2.0 circular reloads (hereafter referred to as Signia™ circular stapler) in patients undergoing left sided colon, sigmoid, or rectal resections in a post market setting.

Detailed description

The primary objective of this study is to evaluate the safety and performance of the Signia™ circular stapler, for the creation of anastomoses assessed by the incidence of anastomotic leak within 30 days following use in subjects undergoing left sided colon, sigmoid, or rectal resections. The secondary objectives of this study are to assess safety and performance outcomes within 90 days following the use of the Signia™ circular stapler in subjects undergoing left sided colon, sigmoid, or rectal resections.

Interventions

DEVICESignia™ circular stapler with Tri-Staple™ Technology (Signia™ Circular Stapling system)

Signia™ Circular Stapling system used for the creation of an anastomosis

Sponsors

Medtronic - MITG
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

Preoperative Inclusion Criteria: 1. Subject is competent and willing to provide documented informed consent to participate in this clinical study 2. Subject is intended to undergo an elective left sided colon/colorectal procedure where a creation of an anastomosis will be completed with the Signia™ circular stapler 3. Subject is ≥ 18 years of age at time of consent Preoperative

Exclusion criteria

1. Subject is unable or unwilling to comply with the study requirements or follow-up schedule 2. Subject with ASA classification ≥ IV 3. Subject is pregnant (as determined by standard site practices) 4. The procedure is an emergency procedure 5. The procedure is a revision/reoperation for the same indication 6. The subject has a documented confounding medical condition which in the opinion of the investigator, will not be appropriate for the study, or the subject has an estimated life expectancy of less than 6 months 7. Subject has participated or plans to participate in an investigational drug or device research study that would interfere with the results of this study 8. Subject will undergo multiple synchronous colon resections 9. Subject with a bleeding disorder or is undergoing anticoagulant treatment that has not been reversed (anticoagulant prophylaxis prescribed as part of the surgical protocol is allowed) 10. Subject has undergone chemotherapy or received biologics within 6 weeks prior to the day of the procedure 11. Subject has history of chronic corticosteroid use (used greater than 3 months within a year prior to the index procedure) 12. Subject has chronic immunosuppression therapy (used greater than 3 months within a year prior to the index procedure) 13. Any subject undergoing an ileal-anal pouch anastomosis surgery Intraoperative

Design outcomes

Primary

MeasureTime frameDescription
Incidence of anastomotic leakwithin 30 days, +/- 14 daysIncidence of anastomotic leak following the use of the Signia™ circular stapler used in subjects undergoing left sided colon, sigmoid, or rectal resections. Diagnosis will be confirmed postoperatively by computed tomography (CT) imaging (with or without a contrast agent), or postoperatively via direct verification during re-operation. Anastomotic leakage confirmed to have occurred at a staple line other than the colon/colorectal anastomosis created with the Signia™ circular stapler will not impact the primary endpoint analysis.

Secondary

MeasureTime frameDescription
Incidence of anastomotic leakswithin 90 days, +/- 14 daysIncidence of anastomotic leak following the use of the Signia™ circular stapler used in subjects undergoing left sided colon, sigmoid, or rectal resections. Diagnosis will be confirmed postoperatively by computed tomography (CT) imaging (with or without a contrast agent), or postoperatively via direct verification during re-operation. Anastomotic leakage confirmed to have occurred at a staple line other than the colon/colorectal anastomosis created with the Signia™ circular stapler will not impact the primary endpoint analysis.
Clinical significance of anastomotic leakswithin 90 days, +/- 14 daysAnastomotic leaks graded according to International Study Group of Rectal Cancer (ISGRC): Grade A: Anastomotic leakage results in no change in patients' management. Grade B: Leakage requires active therapeutic intervention but is manageable without re-laparotomy/operative intervention\*. Grade C: Anastomotic leakage requires re-laparotomy/operative intervention\*. \*Operative intervention was added to the ISGRC definition for the purpose of this study.
Incidence of a Signia™ circular stapler and accessory components device deficiency (DD)Day 0 (day of surgery)Inadequacy of a medical device with respect to its identity, quality, durability, reliability, usability, safety, or performance.
Incidence of anastomotic bleedingwithin 30 and 90 days, +/- 14 daysbleeding at the anastomotic site that requires endoscopic or surgical intervention
Incidence of device-related adverse eventswithin 90 days, +/- 14 daysAdverse events related to Signia™ circular stapler and accessory components. An adverse event is defined as "Any untoward medical occurrence, unintended disease or injury, or untoward clinical signs (including abnormal laboratory findings) in subjects, users or other persons, whether or not related to the investigational medical device and whether anticipated or unanticipated."
Length of hospital staydischarge (post-surgery up to 90 days, +/- 14 days)Length of hospital stay for the index procedure (from admission to discharge) after the Signia™ circular stapler was used in subjects undergoing left sided colon, sigmoid, or rectal resections
Incidence of re-operation or surgical interventionwithin 90 days, +/- 14 daysIncidence of re-operation or surgical intervention due to an adverse event related to the Signia™ circular stapler or accessory components

Countries

United States

Contacts

CONTACTYeshareg Yismaw
yeshareg.g.yismaw@medtronic.com+7635050079
CONTACTStudy Mailbox
rs.securestudy@medtronic.com
PRINCIPAL_INVESTIGATORKatharine Louise Jackson, MD, FACS, MBBS, MA

Duke Raleigh Hospital

PRINCIPAL_INVESTIGATORJohn Monson, MD, FACS

Northwell Health

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Sep 2, 2026