Skip to content

TARGET 2.0 Study: Safety and Performance of the Cardiovalve TR Replacement System

TARGET 2.0 Study: Safety and Performance of the Cardiovalve Tricuspid Valve Replacement System in the Treatment of Subjects With Tricuspid Regurgitation- Investigation

Status
Recruiting
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT07334691
Enrollment
150
Registered
2026-01-12
Start date
2026-01-20
Completion date
2033-09-01
Last updated
2026-05-11

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Tricuspid Regurgitation

Brief summary

This investigation is a continuation for "TARGET" investigation and its purpose is to further demonstrate the efficiency and safety of the Cardiovalve system in the treatment of subjects with tricuspid regurgitation. The same subject population will be included, while applying the clinical and scientific knowledge accumulated in the TARGET investigation. This investigation will support the submission for obtaining marketing approval.

Detailed description

"TARGET 2.0": Safety and Performance of the Cardiovalve Tricuspid valve replacement system in the treatment of subjects with tricuspid regurgitation- investigation: Cardiovalve Tricuspid Valve Replacement system (hereinafter referred to as Cardiovalve TR system) The system has not been granted CE mark at this time The Cardiovalve implant consists of three bovine pericardium tissue leaflets, self-expanding dual nitinol frame, and fabric. A total of 24 anchoring points affix the device to the native tricuspid annulus. The Delivery System is intended to deliver the valve in the crimped position via the transfemoral venous approach. It comprises of a catheter assembly and handles. The handles knobs facilitate valve alignment and positioning in the native valve, and control the capsule expansion and release of the Cardiovalve implant. The Cardiovalve TR Valve Replacement System is intended for reduction of tricuspid regurgitation (TR) in patients with symptomatic severe or greater secondary tricuspid regurgitation despite being treated with medical therapy for whom tricuspid valve replacement is deemed appropriate by a Heart Team. The system percutaneously delivers the Implant to the tricuspid valve via femoral vein access This investigation is a continuation for "TARGET" investigation and its purpose is to further demonstrate the efficiency and safety of the Cardiovalve system in the treatment of subjects with tricuspid regurgitation. The same subject population will be included, while applying the clinical and scientific knowledge accumulated in the TARGET investigation. This investigation will support the submission for obtaining marketing approval.

Interventions

Cardiovalve Tricuspid Valve Replacement system

Sponsors

Cardiovalve Ltd.
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 85 Years
Healthy volunteers
No

Inclusion criteria

1. Subject is ≥ 18 and \<85 years 2. Severe tricuspid regurgitation (TR) ≥3+ based upon echocardiography, as assessed by independent core laboratory using a 5-grade classification (mild (1), moderate (2), severe (3), massive (4), torrential (5)). Trace and no TR is considered 0)29 3. Symptomatic, NYHA Class II-IV 4. Left ventricular ejection fraction (LVEF) ≥ 30% 5. Subject adequately treated based upon medical standards 6. Subjects are at high risk for open heart surgery 7. Subject provided written, informed consent before investigation enrollment 8. Subject approved by the Subject Screening Committee Anatomical Inclusion Criteria (measured by CT) 9. Right femoral vein diameter \> 9mm 10. Tricuspid valve diameter \< 55 mm 11. RV length \> 45 mm

Exclusion criteria

Subjects will be excluded from the investigation if fulfill any of the following criteria: 1. Cardiac anatomy deemed not suitable for the Cardiovalve TR system as evaluated (by CT) 2. Venous peripheral anatomy or any spinal anatomy that is unsuitable for Cardiovalve TR implant delivery (by CT) 3. Primary tricuspid disease that may interfere with Cardiovalve implantation 4. Severe right ventricular failure (by Echo core lab adjudication) 5. Significant coronary artery disease requiring percutaneous or surgical intervention 6. Severe systolic pulmonary arterial pressure, pASP \> 2/3 systemic BP with PVR \> 5 Wood units after vasodilator challenge 7. Presence of any known life threatening non-cardiac disease that will limit the subject's life expectancy to less than one year 8. Cerebrovascular event (stroke, TIA) within the past 3 months 9. Active endocarditis or history of mitral/tricuspid endocarditis within 3 months or infection requiring antibiotic within 2 weeks before index procedure 10. Subject has significant other sided valvular heart disease which requires treatment (e.g. mitral regurgitation or stenosis, or aortic regurgitation or stenosis) 11. Documented primary coagulopathy or platelet disorder, including thrombocytopenia (absolute platelet count \<90k) 12. Documented evidence of significant renal dysfunction (eGFR\<30 ml/min/1.73m2) or any form of dialysis at time of screening within 30 days 13. Untreatable hypersensitivity or contraindication to any of the following: all antiplatelets, all anticoagulants, nitinol alloys (nickel and titanium), bovine tissue, glutaraldehyde, contrast media, or Polyethylene Glycol (PEG) 14. Subjects unsuitable for implantation due to thrombosis of the lower venous system or presence of a vena cava filter 15. Evidence of an acute myocardial infarction (AMI) ≤ 1 month (30 days) 16. Liver cirrhosis \> Child-Pugh Class A 17. Psychiatric or behavioral disease including known alcohol or drug abuser that is likely to impair compliance with protocol 18. Pregnant, lactating or planning pregnancy within next 12 months 19. Requirement for antibiotic treatment within the last 48 hours 20. Surgical or interventional procedure planned within 30 days prior to index procedure 21. Refractory heart failure requiring advanced intervention (i.e. left ventricular assist device, transplantation) or UNOS Status 1 heart transplant or prior orthotropic heart transplantation. 22. Prior Tricuspid valve surgery or transcatheter tricuspid valve procedure that may interfere with the Cardiovalve device. Valve in a valve procedure is excluded. 23. Modified Rankin Scale \> 4 disability 24. Implant or revision of any rhythm management device (CRT or CRT-D) or implantable cardioverter-defibrillator within 30 days prior to index procedure 25. Acutely decompensated heart failure (i.e. hemodynamically unstable or requiring IV inotrope) at the time of screening 26. Severe COPD or continuous use of home oxygen 27. Hgb \< 9 g/dL at screening 28. The subject has contraindication against a transesophageal echo (TEE) during the procedure that cannot be replaced by other imaging. 29. Currently participating in an investigational drug or another device investigation which has not reached its primary endpoint 30. Subjects with \>2 leads or with any lead that may interfere with Cardiovalve procedure or device

Design outcomes

Primary

MeasureTime frameDescription
Freedom from device or procedure-related adverse events30 daysFreedom from device or procedure-related adverse events
Reduction in TR grade30 daysReduction in TR in comparison to baseline

Secondary

MeasureTime frameDescription
Six minute walk test30 days, 6 months, 12 months, annual for five yearsChange in Six minute walk distance from Baseline
KCCQ30 days, 6 months, 12 months, annual for five yearsChange in health status from Baseline

Countries

Germany

Contacts

CONTACTDana Raveh Arbel
danar@cardiovalve.com0528591891
PRINCIPAL_INVESTIGATORGeorg Nickenig

Bonn Clinic

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: May 12, 2026