Skip to content

Single- vs Double-Layer Cesarean Scar Repair and Myometrial Thickness

Effects of Single-Layer Versus Double-Layer Cesarean Scar Repair on Myometrial Thickness and Associated Clinical Outcomes

Status
Recruiting
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT07323355
Enrollment
102
Registered
2026-01-07
Start date
2025-11-11
Completion date
2026-11-15
Last updated
2026-01-07

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Caesarean Section, Cesarean Scar Closure, Cesarean Scar Defect (Isthmococele), Clinical Outcomes, Myometrial Thickness, Postpartum Complications

Keywords

Caesarean Section, Cesarean Scar Closure, Isthmococele, Myometrial Thickness

Brief summary

Cesarean delivery (CD) is one of the most commonly performed surgical procedures worldwide, with a rising incidence particularly in high-income countries. Although often life-saving, cesarean delivery carries both short- and long-term maternal risks. Early complications include infection, hemorrhage, and thromboembolism, while inadequate uterine healing can lead to future complications such as uterine rupture and placenta accreta spectrum disorders. Additionally, cesarean scars may result in pregnancy complications, isthmocele formation, postmenstrual bleeding, pelvic pain, and dysmenorrhea. This highlights the need for optimization of the surgical technique. Despite increasing cesarean rates, there is no consensus on the optimal uterine closure method. Techniques vary in terms of the number of layers, suture locking style, and inclusion of the endometrium, and their comparative effectiveness in reducing scar defects remains unclear. Some previous studies have reported increased uterine rupture risk with single-layer locked sutures and better healing with double-layer closure, while others found no significant difference in scar outcomes. This study aims to investigate the effects of single- versus double-layer cesarean scar closure on myometrial thickness and its clinical implications.

Interventions

PROCEDUREDouble-Layer Cesarean Scar Repair

Participants in this arm undergo double-layer closure of the uterine incision during cesarean delivery. The procedure involves suturing the full thickness of the myometrium in the first layer, followed by a second continuous suture approximating the outer myometrium and serosa. Outcomes such as myometrial thickness, scar integrity, and clinical parameters are measured. This arm is compared in parallel with the single-layer cesarean scar repair arm.

PROCEDURESingle-Layer Cesarean Scar Repair

Participants in this arm undergo single-layer closure of the uterine incision during cesarean delivery. The procedure involves a single continuous suture approximating the full thickness of the uterine wall. Outcomes such as myometrial thickness, scar integrity, and clinical parameters are measured. This arm is compared in parallel with the double-layer cesarean scar repair arm.

Sponsors

Ankara City Hospital Bilkent
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
QUADRUPLE (Subject, Caregiver, Investigator, Outcomes Assessor)

Eligibility

Sex/Gender
FEMALE
Age
18 Years to 44 Years
Healthy volunteers
Yes

Inclusion criteria

* Female participants aged 18-44 years. * Undergoing cesarean delivery at the study hospital's Obstetrics and Gynecology clinic. * Evaluated as clinically eligible based on history, physical examination, abdominal ultrasonography, and routine preoperative laboratory tests, including: Complete blood count (CBC), biochemical profile, prothrombin time (PT), activated partial thromboplastin time (aPTT), blood group determination. No abnormalities detected in the above assessments.

Exclusion criteria

\- Presence of chronic diseases, including: Rheumatologic diseases, renal failure, vascular malformations, hypertension, cardiac disease, diabetes mellitus, obesity, thyroid disease, congenital hematologic disorders. * Suspected or confirmed placenta previa or placenta accreta spectrum. * Clinical chorioamnionitis. * Anterior wall uterine myomas. * History of low transverse nonstandard uterine incision. * Predicted obstetric hemorrhage or other intraoperative complications.

Design outcomes

Primary

MeasureTime frameDescription
Myometrial Thickness at Cesarean Scar Site6 months postoperativelyMyometrial thickness at the cesarean scar site will be measured using transvaginal ultrasonography (TVUSG) by a qualified obstetrician at 6 months after surgery to compare the effects of single-layer versus double-layer cesarean scar closure. Measurement Tool / Parameter: TVUSG; residual myometrial thickness (mm). Units of Measure: Millimeters (mm).

Secondary

MeasureTime frameDescription
Cesarean Scar-Related Symptoms6 months postoperativelyPresence of cesarean scar-related symptoms at 6 months after surgery. Parameters Assessed: Postmenstrual spotting (yes/no), pelvic pain (yes/no), dyspareunia (yes/no) Measurement Tool / Method: Clinical interview during follow-up visit and review of outpatient medical records. Units of Measure: Incidence (n, %)
Cesarean Scar Defect (Isthmocele)6 months postoperativelyPresence of cesarean scar defect (isthmocele) detected by transvaginal ultrasonography. Measurement Tool / Method: Transvaginal ultrasonography. Units of Measure: Incidence (number of participants with isthmocele, %)
Major Uterine Scar-Related ComplicationsUp to 6 months postoperativelyOccurrence of major uterine scar-related complications within 6 months after surgery. Parameters Assessed: Uterine rupture, cesarean scar pregnancy, abnormal uterine bleeding Measurement Tool / Method: Clinical examination and medical record review. Units of Measure: Incidence (n, %)
Morphological Characteristics of Cesarean Scar Defect6 months postoperativelyMorphological characteristics of cesarean scar defect measured by transvaginal ultrasonography. Parameters Assessed: Isthmocele depth (mm), isthmocele width (mm) Measurement Tool / Method: Transvaginal ultrasonography. Units of Measure: Millimeters (mm)

Countries

Turkey (Türkiye)

Contacts

Primary ContactMerve Didem Eşkin Tanrıverdi, MD
mrvddm@hotmail.com+905354071467

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026